Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 222

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Assessment of stroke volume variation for prediction of fluid responsiveness using the modified FloTrac™ and PiCCOplus™ system

Open access
Hofer, Christoph K, Senn, Alban, Weibel, Luc, Zollinger, Andreas · 2008 · Critical Care

Abstract

Introduction: Stroke volume variation (SVV) has repeatedly been shown to be a reliable predictor of fluid responsiveness. Various devices allow automated clinical assessment of SVV. The aim of the present study was to compare prediction of fluid responsiveness using SVV, as determined by the FloTrac™/Vigileo™ system and the PiCCOplus™ system. Methods: In patients who had undergone elective cardiac surgery, SVV FloTrac was determined via radial FloTrac sensor, and SVV PiCCO and pulse pressure variation were assessed via a femoral PiCCO catheter. Stroke volume was assessed by transpulmonary thermodilution. All variables were recorded before and after a volume shift induced by a change in body positioning (from 30° head-up position to 30° head-down position). Pearson correlation, t-test, and Bland-Altman analysis were performed. Area under the curve was determined by plotting receiver operating characteristic curves for changes in stroke volume in excess of 25%. P < 0.05 was considered statistically significant. Results: Body positioning resulted in a significant increase in stroke volume; SVV FloTrac and SVV PiCCO decreased significantly. Correlations of SVV FloTrac and SVV PiCCO with change in stroke volume were similar. There was no significant difference between the areas under the curve for SVV FloTrac and SVV PiCCO; the optimal threshold values given by the receiver operating characteristic curves were 9.6% for SVV FloTrac (sensitivity 91% and specificity 83%) and 12.1% for SVV PiCCO (sensitivity 87% and specificity 76%). There was a clinically acceptable agreement and strong correlation between SVV FloTrac and SVV PiCCO. Conclusion: SVVs assessed using the FloTrac™/Vigileo™ and the PiCCOplus™ systems exhibited similar performances in terms of predicting fluid responsiveness. In comparison with SVV PiCCO, SVV FloTrac has a lower threshold value.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/cc6933

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Hofer, C. K., Senn, A., Weibel, L., & Zollinger, A.
Venue
Critical Care
Published
2008-06-20
Volume
12
Issue
3
Pages
R82-R82
ISSN
1364-8535 (ISSN-L)
OpenAlex
W2034566404
Cited by
222
References
1
FWCI
21.33
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.