The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Assessment of stroke volume variation for prediction of fluid responsiveness using the modified FloTrac™ and PiCCOplus™ system
Open accessAbstract
Introduction: Stroke volume variation (SVV) has repeatedly been shown to be a reliable predictor of fluid responsiveness. Various devices allow automated clinical assessment of SVV. The aim of the present study was to compare prediction of fluid responsiveness using SVV, as determined by the FloTrac™/Vigileo™ system and the PiCCOplus™ system. Methods: In patients who had undergone elective cardiac surgery, SVV FloTrac was determined via radial FloTrac sensor, and SVV PiCCO and pulse pressure variation were assessed via a femoral PiCCO catheter. Stroke volume was assessed by transpulmonary thermodilution. All variables were recorded before and after a volume shift induced by a change in body positioning (from 30° head-up position to 30° head-down position). Pearson correlation, t-test, and Bland-Altman analysis were performed. Area under the curve was determined by plotting receiver operating characteristic curves for changes in stroke volume in excess of 25%. P < 0.05 was considered statistically significant. Results: Body positioning resulted in a significant increase in stroke volume; SVV FloTrac and SVV PiCCO decreased significantly. Correlations of SVV FloTrac and SVV PiCCO with change in stroke volume were similar. There was no significant difference between the areas under the curve for SVV FloTrac and SVV PiCCO; the optimal threshold values given by the receiver operating characteristic curves were 9.6% for SVV FloTrac (sensitivity 91% and specificity 83%) and 12.1% for SVV PiCCO (sensitivity 87% and specificity 76%). There was a clinically acceptable agreement and strong correlation between SVV FloTrac and SVV PiCCO. Conclusion: SVVs assessed using the FloTrac™/Vigileo™ and the PiCCOplus™ systems exhibited similar performances in terms of predicting fluid responsiveness. In comparison with SVV PiCCO, SVV FloTrac has a lower threshold value.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hanley, J. A., & McNeil, B. J. (1983) · Radiology · doi:10.1148/radiology.148.3.6878708 · Cited by 7,016
Cited by
Marik, P. E., Cavallazzi, R., Vasu, T., & Hirani, A. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181a590da · Cited by 1,272
Marik, P. E., & Cavallazzi, R. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31828a25fd · Cited by 866
Cannesson, M., Le Manach, Y., Hofer, C. K., Goarin, J. P., Lehot, J.-J., Vallet, B., & Tavernier, B. (2011) · Anesthesiology · doi:10.1097/aln.0b013e318225b80a · Cited by 554
Self-citationMurray, M. J., DeBlock, H., Erstad, B., Gray, A., Jacobi, J., Jordan, C., McGee, W., McManus, C., Meade, M., Nix, S., et al. (2016) · Critical Care Medicine · doi:10.1097/ccm.0000000000002027 · Cited by 517
Perioperative fluid therapy: a statement from the international Fluid Optimization Group
Navarro, L. H. C., Bloomstone, J. A., Auler, J. O. C., Cannesson, M., Rocca, G. D., Gan, T. J., Kinsky, M., Magder, S., Miller, T. E., Mythen, M., et al. (2015) · Perioperative Medicine · doi:10.1186/s13741-015-0014-z · Cited by 298
Metadata
- Authors
- Hofer, C. K., Senn, A., Weibel, L., & Zollinger, A.
- Venue
- Critical Care
- Published
- 2008-06-20
- Volume
- 12
- Issue
- 3
- Pages
- R82-R82
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W2034566404
- Cited by
- 222
- References
- 1
- FWCI
- 21.33
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.