A systematic review on quality indicators for tight glycaemic control in critically ill patients: need for an unambiguous indicator reference subset
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Introduction: The objectives of this study were to systematically identify and summarize quality indicators of tight glycaemic control in critically ill patients, and to inspect the applicability of their definitions. Methods: We searched in MEDLINE® for all studies evaluating a tight glycaemic control protocol and/or quality of glucose control that reported original data from a clinical trial or observational study on critically ill adult patients. Results: Forty-nine studies met the inclusion criteria; 30 different indicators were extracted and categorized into four nonorthogonal categories: blood glucose zones (for example, 'hypoglycaemia'); blood glucose levels (for example, 'mean blood glucose level'); time intervals (for example, 'time to occurrence of an event'); and protocol characteristics (for example, 'blood glucose sampling frequency'). Hypoglycaemia-related indicators were used in 43 out of 49 studies, acting as a proxy for safety, but they employed many different definitions. Blood glucose level summaries were used in 41 out of 49 studies, reported as means and/or medians during the study period or at a certain time point (for example, the morning blood glucose level or blood glucose level upon starting insulin therapy). Time spent in the predefined blood glucose level range, time needed to reach the defined blood glucose level target, hyperglycaemia-related indicators and protocol-related indicators were other frequently used indicators. Most indicators differ in their definitions even when they are meant to measure the same underlying concept. More importantly, many definitions are not precise, prohibiting their applicability and hence the reproducibility and comparability of research results. Conclusions: An unambiguous indicator reference subset is necessary. The result of this systematic review can be used as a starting point from which to develop a standard list of well defined indicators that are associated with clinical outcomes or that concur with clinicians' subjective views on the quality of the regulatory process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intensive insulin therapy in the medical ICU
Van den Berghe, G., Wilmer, A., Hermans, G., Meersseman, W., Wouters, P. J., Milants, I., Van Wijngaerden, E., Bobbaers, H., & Bouillon, R. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa052521 · Cited by 3,639 · cited 2×
“Attempts at achieving TGC, however, are not perfect and carry a risk for hypoglycaemia [4,5].”
BackgroundLog-normal distributions across the sciences: keys and clues
LIMPERT, E., STAHEL, W. A., & ABBT, M. (2001) · BioScience · doi:10.1641/0006-3568(2001)051[0341:lndats]2.0.co;2 · Cited by 2,621 · cited 1×
“Finally, a statistical point worth noting is that most BGL distributions are log-normal rather than normal [39], and hence nonparametric measures such as the median and interquartile range are likely to be more appropriate for summarizing the data and inference [ 40 ].”
BackgroundCapes, S. E., Hunt, D., Malmberg, K., & Gerstein, H. C. (2000) · The Lancet · doi:10.1016/s0140-6736(99)08415-9 · Cited by 2,187 · cited 1×
“Introduction Hyperglycaemia is frequently encountered in critically ill patients [1,2].”
BackgroundHermayer, K. L., Neal, D. E., Hushion, T. V., Irving, M. G., Arnold, P. C., Kozlowski, L., Stroud, M. R., Kerr, F. B., & Kratz, J. M. (2007) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2007.0225 · Cited by 38
Cited by
Jacobi, J., Bircher, N., Krinsley, J., Agus, M., Braithwaite, S. S., Deutschman, C., Freire, A. X., Geehan, D., Kohl, B., Nasraway, S. A., et al. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182653269 · Cited by 571
International recommendations for glucose control in adult non diabetic critically ill patients
Ichai, C., Preiser, J.-C., (SFAR), F. T. S. F. D.-R., & Société de Réanimation de langue Française (SRLF) and the Experts group (2010) · Critical Care · doi:10.1186/cc9258 · Cited by 127
Juneja, R., Roudebush, C. P., Nasraway, S. A., Golas, A. A., Jacobi, J., Carroll, J., Nelson, D., Abad, V. J., & Flanders, S. J. (2009) · Critical Care · doi:10.1186/cc8129 · Cited by 86
Schultz, M. J., Harmsen, R. E., & Spronk, P. E. (2010) · Critical Care · doi:10.1186/cc8966 · Cited by 53
Self-citationStrom, B. L., Schinnar, R., Bilker, W., Hennessy, S., Leonard, C. E., & Pifer, E. (2010) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.2009.000695 · Cited by 51
Metadata
- Authors
- Eslami, S., de Keizer, N. F., de Jonge, E., Schultz, M. J., & Abu-Hanna, A.
- Venue
- Critical Care
- Published
- 2008-11-11
- Volume
- 12
- Issue
- 6
- Pages
- R139-R139
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W2136400751
- Cited by
- 60
- References
- 4
- FWCI
- 1.36
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.