Comprehensive comparison of three commercial human whole-exome capture platforms
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Background: Exome sequencing, which allows the global analysis of protein coding sequences in the human genome, has become an effective and affordable approach to detecting causative genetic mutations in diseases. Currently, there are several commercial human exome capture platforms; however, the relative performances of these have not been characterized sufficiently to know which is best for a particular study. Results: We comprehensively compared three platforms: NimbleGen's Sequence Capture Array and SeqCap EZ, and Agilent's SureSelect. We assessed their performance in a variety of ways, including number of genes covered and capture efficacy. Differences that may impact on the choice of platform were that Agilent SureSelect covered approximately 1,100 more genes, while NimbleGen provided better flanking sequence capture. Although all three platforms achieved similar capture specificity of targeted regions, the NimbleGen platforms showed better uniformity of coverage and greater genotype sensitivity at 30- to 100-fold sequencing depth. All three platforms showed similar power in exome SNP calling, including medically relevant SNPs. Compared with genotyping and whole-genome sequencing data, the three platforms achieved a similar accuracy of genotype assignment and SNP detection. Importantly, all three platforms showed similar levels of reproducibility, GC bias and reference allele bias. Conclusions: We demonstrate key differences between the three platforms, particularly advantages of solutions over array capture and the importance of a large gene target set.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Initial sequencing and analysis of the human genome
International Human Genome Sequencing Consortium, Whitehead Institute for Biomedical Research, C. F. G. R., Lander, E. S., Linton, L. M., Birren, B., Nusbaum, C., Zody, M. C., Baldwin, J., Devon, K., Dewar, K., et al. (2001) · Nature · doi:10.1038/35057062 · Cited by 24,216 · cited 1×
“Even after a decade’s effort by the genetics research community since the completion of the first human genome sequences [1,2], most genetic mutations underlying human diseases remain undiscovered.”
Self-citationThe sequence of the human genome
Venter, J. C., Adams, M. D., Myers, E. W., Li, P. W., Mural, R. J., Sutton, G. G., Smith, H. O., Yandell, M., Evans, C. A., Holt, R. A., et al. (2001) · Science · doi:10.1126/science.1058040 · Cited by 13,909
Self-citationFinding the missing heritability of complex diseases
Manolio, T. A., Collins, F. S., Cox, N. J., Goldstein, D. B., Hindorff, L. A., Hunter, D. J., McCarthy, M. I., Ramos, E. M., Cardon, L. R., Chakravarti, A., et al. (2009) · Nature · doi:10.1038/nature08494 · Cited by 8,336 · cited 1×
“For example, the causative mutations for more than half of human rare diseases [3], the genetic architecture of most common diseases [4,5] and the roles of somatic mutations in most cancers [6] have yet to be characterized.”
BackgroundGenome sequencing in microfabricated high-density picolitre reactors
Margulies, M., Egholm, M., Altman, W. E., Attiya, S., Bader, J. S., Bemben, L. A., Berka, J., Braverman, M. S., Chen, Y.-J., Chen, Z., et al. (2005) · Nature · doi:10.1038/nature03959 · Cited by 7,693 · cited 1×
“Whole genome re-sequencing can potentially identify these uncharacterized mutations, and in the past few years great strides have been made in this regard with massively parallel DNA sequencing technologies that can be applied to the whole genome [7-10].”
BackgroundSOAP2: an improved ultrafast tool for short read alignment
Li, R., Yu, C., Li, Y., Lam, T.-W., Yiu, S.-M., Kristiansen, K., & Wang, J. (2009) · Bioinformatics · doi:10.1093/bioinformatics/btp336 · Cited by 3,760 · cited 1×
“21) [29] was used to align the reads to the NCBI human genome reference assembly (build 36.”
MethodSelf-citationAccurate whole human genome sequencing using reversible terminator chemistry
Bentley, D. R., Balasubramanian, S., Swerdlow, H. P., Smith, G. P., Milton, J., Brown, C. G., Hall, K. P., Evers, D. J., Barnes, C. L., Bignell, H. R., et al. (2008) · Nature · doi:10.1038/nature07517 · Cited by 3,684
Self-citationStratton, M. R., Campbell, P. J., & Futreal, P. A. (2009) · Nature · doi:10.1038/nature07943 · Cited by 3,449 · cited 1×
“For example, the causative mutations for more than half of human rare diseases [3], the genetic architecture of most common diseases [4,5] and the roles of somatic mutations in most cancers [6] have yet to be characterized.”
BackgroundA general method for isolation of high molecular weight DNA from eukaryotes
Blin, N., & Stafford, D. W. (1976) · Nucleic Acids Research · doi:10.1093/nar/3.9.2303 · Cited by 2,770 · cited 1×
“Genomic DNA was extracted from a lymphoblastoid cell line of YanHuang [26] using proteinase K and phenol/ chloroform [27] and further subjected to RNase treatment.”
MethodTargeted capture and massively parallel sequencing of 12 human exomes
Ng, S. B., Turner, E. H., Robertson, P. D., Flygare, S. D., Bigham, A. W., Lee, C., Shaffer, T., Wong, M., Bhattacharjee, A., Eichler, E. E., et al. (2009) · Nature · doi:10.1038/nature08250 · Cited by 2,030 · cited 4×
“[11,15-21], and have also been adopted in efforts towards deciphering human common disease and cancer genomes.”
BackgroundInfluentialExome sequencing identifies the cause of a mendelian disorder
Ng, S. B., Buckingham, K. J., Lee, C., Bigham, A. W., Tabor, H. K., Dent, K. M., Huff, C. D., Shannon, P. T., Jabs, E. W., Nickerson, D. A., et al. (2010) · Nature Genetics · doi:10.1038/ng.499 · Cited by 1,957 · cited 1×
“[11,15-21], and have also been adopted in efforts towards deciphering human common disease and cancer genomes.”
Background
Cited by
Sequencing depth and coverage: key considerations in genomic analyses
Sims, D., Sudbery, I., Ilott, N. E., Heger, A., & Ponting, C. P. (2014) · Nature Reviews Genetics · doi:10.1038/nrg3642 · Cited by 1,393
Guidelines for Validation of Next-Generation Sequencing–Based Oncology Panels
Jennings, L. J., Arcila, M. E., Corless, C., Kamel-Reid, S., Lubin, I. M., Pfeifer, J., Temple-Smolkin, R. L., Voelkerding, K. V., & Nikiforova, M. N. (2017) · The Journal of Molecular Diagnostics · doi:10.1016/j.jmoldx.2017.01.011 · Cited by 743
Cooper, D. N., Krawczak, M., Polychronakos, C., Tyler-Smith, C., & Kehrer-Sawatzki, H. (2013) · Human Genetics · doi:10.1007/s00439-013-1331-2 · Cited by 645
Self-citationTargeted Next-Generation Sequencing can Replace Sanger Sequencing in Clinical Diagnostics
Sikkema-Raddatz, B., Johansson, L. F., de Boer, E. N., Almomani, R., Boven, L. G., van den Berg, M. P., van Spaendonck-Zwarts, K. Y., van Tintelen, J. P., Sijmons, R. H., Jongbloed, J. D. H., et al. (2013) · Human Mutation · doi:10.1002/humu.22332 · Cited by 300
Evaluation of Hybridization Capture Versus Amplicon‐Based Methods for Whole‐Exome Sequencing
Samorodnitsky, E., Jewell, B. M., Hagopian, R., Miya, J., Wing, M. R., Lyon, E., Damodaran, S., Bhatt, D., Reeser, J. W., Datta, J., et al. (2015) · Human Mutation · doi:10.1002/humu.22825 · Cited by 274
Xue, Y., Chen, Y., Ayub, Q., Huang, N., Ball, E. V., Mort, M., Phillips, A. D., Shaw, K., Stenson, P. D., Cooper, D. N., et al. (2012) · The American Journal of Human Genetics · doi:10.1016/j.ajhg.2012.10.015 · Cited by 274
Self-citationPatterns of coding variation in the complete exomes of three Neandertals
Castellano, S., Parra, G., Sánchez-Quinto, F. A., Racimo, F., Kuhlwilm, M., Kircher, M., Sawyer, S., Fu, Q., Heinze, A., Nickel, B., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1405138111 · Cited by 247
Exome Sequencing: Current and Future Perspectives
Warr, A., Robert, C., Hume, D., Archibald, A., Deeb, N., & Watson, M. (2015) · G3 Genes|Genomes|Genetics · doi:10.1534/g3.115.018564 · Cited by 224
Performance comparison of four exome capture systems for deep sequencing
Chilamakuri, C. S., Lorenz, S., Madoui, M.-A., Vodák, D., Sun, J., Hovig, E., Myklebost, O., & Meza-Zepeda, L. A. (2014) · BMC Genomics · doi:10.1186/1471-2164-15-449 · Cited by 185
“…et al . compared NimbleGen Sequence Capture Array, NimbleGen SeqCap EZ, and Agilent SureSelect, and showed that all three technologies achieved a similar accuracy of genotype assignment and single nucleotide polymorphism (SNP) detection, and had similar levels of reproducibility and GC bias [12].”
BackgroundMIPgen: optimized modeling and design of molecular inversion probes for targeted resequencing
Boyle, E. A., O’Roak, B. J., Martin, B. K., Kumar, A., & Shendure, J. (2014) · Bioinformatics · doi:10.1093/bioinformatics/btu353 · Cited by 172
A glimpse into past, present, and future DNA sequencing
Morey, M., Fernández-Marmiesse, A., Castiñeiras, D., Fraga, J. M., Couce, M. L., & Cocho, J. A. (2013) · Molecular Genetics and Metabolism · doi:10.1016/j.ymgme.2013.04.024 · Cited by 158
Metadata
- Authors
- Asan, Xu, Y., Jiang, H., Tyler-Smith, C., Xue, Y., Jiang, T., Wang, J., Wu, M., Liu, X., Tian, G., Wang, J., Wang, J., Yang, H., & Zhang, X.
- Venue
- Genome Biology
- Published
- 2011-09-28
- Volume
- 12
- Issue
- 9
- Pages
- R95-R95
- ISSN
- 1465-6906 (ISSN-L)
- 1474-760X
- OpenAlex
- W2140247415
- Cited by
- 164
- References
- 30
- FWCI
- 12.61
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.