Ultrasound-guided “short” midline catheters for difficult venous access in the emergency department: a retrospective analysis
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Acutely ill patients admitted to the emergency department (ED) constantly require at least one fast and reliable peripheral intravenous (PIV) access. In many conditions (morbid obesity, underweight state, chronic diseases, intravenous drug abuse, adverse local conditions, etc.), PIV placement may be challenging. Ultrasound guidance is a useful tool for obtaining a peripheral intravenous access in the emergency department, particularly when superficial veins are difficult to identify by palpation and direct visualization, though standard peripheral intravenous cannulas are not ideal for this technique of insertion and may have limited duration. Long polyurethane catheters inserted with ultrasound guidance and direct Seldinger technique appear to have several advantages over short cannulas in terms of success of insertion and of duration. METHODS: A retrospective analysis was conducted on all the ultrasound-guided peripheral venous accesses obtained by insertion of long polyurethane catheters in patients admitted to the emergency department of our university hospital during 1 year. The main indication to the procedure was the urgent need of a peripheral venous access in patients with superficial veins difficult to palpate and/or visualize. All relevant data concerning the insertion and the maintenance of these peripheral lines were collected from the chart. RESULTS: Seventy-six patients were included in this review. The success rate of insertion was 100 %, with an average of 1.57 punctures per each successful cannulation. The mean time needed for the complete procedure was 9.5 min. In 73 % of patients, the catheter was used for more than 1 week; a minority of catheters were removed prematurely for end of use. No major infective or thrombotic complication was reported. CONCLUSIONS: In our experience, 8- to 10-cm-long polyurethane catheters may offer a fast and reliable peripheral venous access in the emergency department, if placed by ultrasound guidance and with the Seldinger technique. Further studies with prospective, randomized, and controlled design are warranted to confirm our results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Costantino, T. G., Parikh, A. K., Satz, W. A., & Fojtik, J. P. (2005) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2004.12.026 · Cited by 435
The epidemiology of peripheral vein infusion thrombophlebitis: a critical review
Tagalakis, V., Kahn, S. R., Libman, M., & Blostein, M. (2002) · The American Journal of Medicine · doi:10.1016/s0002-9343(02)01163-4 · Cited by 274 · cited 1×
“US-guided peripheral lines appear to have a low rate of long-term complications [25, 26].”
BackgroundUltrasound guidance for difficult peripheral venous access: Systematic review and meta-analysis
Egan, G., Healy, D., O'Neill, H., Clarke-Moloney, M., Grace, P. A., & Walsh, S. R. (2013) · Emergency Medicine Journal · doi:10.1136/emermed-2012-201652 · Cited by 222
Au, A. K., Rotte, M. J., Grzybowski, R. J., Ku, B. S., & Fields, J. M. (2012) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2012.04.016 · Cited by 149
Is peripheral line placement more difficult in obese than in lean patients?
Juvin, P., Blarel, A., Bruno, F., & Desmonts, J.-M. (2003) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000050570.85195.29 · Cited by 73
Ultrasound-guided peripheral venous access: a systematic review of randomized-controlled trials
Liu, Y. T., Alsaawi, A., & Bjornsson, H. M. (2013) · European Journal of Emergency Medicine · doi:10.1097/mej.0b013e328363bebc · Cited by 65
Success of ultrasound-guided peripheral intravenous access with skin marking
Resnick, J. R., Cydulka, R. K., Donato, J., Jones, R. A., & Werner, S. L. (2008) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2008.00174.x · Cited by 39
Cited by
Defining difficult intravenous access (DIVA): a systematic review
Bahl, A., Johnson, S., Alsbrooks, K., Mares, A., Gala, S., & Hoerauf, K. (2023) · The Journal of Vascular Access · doi:10.1177/11297298211059648 · Cited by 82
Rodríguez-Calero, M. A., Blanco-Mavillard, I., Morales-Asencio, J. M., Fernández-Fernández, I., Castro-Sánchez, E., & de Pedro-Gómez, J. E. (2020) · Heart & Lung · doi:10.1016/j.hrtlng.2020.01.009 · Cited by 78
Rodriguez-Calero, M. A., de Pedro-Gomez, J. E., Molero-Ballester, L. J., Fernandez-Fernandez, I., Matamalas-Massanet, C., Moreno-Mejias, L., Blanco-Mavillard, I., Moya-Suarez, A. B., Personat-Labrador, C., & Morales-Asencio, J. M. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9030799 · Cited by 60
“This may produce serious complications associated with vascular access, such as phlebitis, extravasation, bruising, haemorrhages, catheter-associated infection and sepsis, thus aggravating morbidity [9,10].”
BackgroundManagement of difficult intravenous access: a qualitative review
Ng, M., Kwok Fai Mark, L., & Fatimah, L. (2022) · World Journal of Emergency Medicine · doi:10.5847/wjem.j.1920-8642.2022.104 · Cited by 37
Metadata
- Authors
- Scoppettuolo, G., Pittiruti, M., Pitoni, S., Dolcetti, L., Emoli, A., Mitidieri, A., Migliorini, I., & Annetta, M. G.
- Venue
- International Journal of Emergency Medicine
- Published
- 2016-02-04
- Volume
- 9
- Issue
- 1
- Pages
- 3-3
- ISSN
- 1865-1372 (ISSN-L)
- 1865-1380
- OpenAlex
- W2265830224
- Cited by
- 82
- References
- 7
- FWCI
- 12.02
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasound-guided “short” midline catheters for difficult venous access in the emergency department: a retrospective analysis. https://app.cochat.ai/papers/10.1186/s12245-016-0100-0
- The paper
- Scoppettuolo, G., Pittiruti, M., Pitoni, S., Dolcetti, L., Emoli, A., Mitidieri, A., Migliorini, I., & Annetta, M. G. (2016). Ultrasound-guided “short” midline catheters for difficult venous access in the emergency department: a retrospective analysis. International Journal of Emergency Medicine. https://doi.org/10.1186/s12245-016-0100-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.