CoChat

Ultrasound-guided “short” midline catheters for difficult venous access in the emergency department: a retrospective analysis

Open access
Scoppettuolo, Giancarlo, Pittiruti, Mauro, Pitoni, Sara, Dolcetti, Laura, Emoli, Alessandro, Mitidieri, Alessandro, Migliorini, Ivano, Annetta, Maria Giuseppina · 2016 · International Journal of Emergency Medicine
Cited by 82

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Acutely ill patients admitted to the emergency department (ED) constantly require at least one fast and reliable peripheral intravenous (PIV) access. In many conditions (morbid obesity, underweight state, chronic diseases, intravenous drug abuse, adverse local conditions, etc.), PIV placement may be challenging. Ultrasound guidance is a useful tool for obtaining a peripheral intravenous access in the emergency department, particularly when superficial veins are difficult to identify by palpation and direct visualization, though standard peripheral intravenous cannulas are not ideal for this technique of insertion and may have limited duration. Long polyurethane catheters inserted with ultrasound guidance and direct Seldinger technique appear to have several advantages over short cannulas in terms of success of insertion and of duration. METHODS: A retrospective analysis was conducted on all the ultrasound-guided peripheral venous accesses obtained by insertion of long polyurethane catheters in patients admitted to the emergency department of our university hospital during 1 year. The main indication to the procedure was the urgent need of a peripheral venous access in patients with superficial veins difficult to palpate and/or visualize. All relevant data concerning the insertion and the maintenance of these peripheral lines were collected from the chart. RESULTS: Seventy-six patients were included in this review. The success rate of insertion was 100 %, with an average of 1.57 punctures per each successful cannulation. The mean time needed for the complete procedure was 9.5 min. In 73 % of patients, the catheter was used for more than 1 week; a minority of catheters were removed prematurely for end of use. No major infective or thrombotic complication was reported. CONCLUSIONS: In our experience, 8- to 10-cm-long polyurethane catheters may offer a fast and reliable peripheral venous access in the emergency department, if placed by ultrasound guidance and with the Seldinger technique. Further studies with prospective, randomized, and controlled design are warranted to confirm our results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s12245-016-0100-0

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 82

Metadata

Authors
Scoppettuolo, G., Pittiruti, M., Pitoni, S., Dolcetti, L., Emoli, A., Mitidieri, A., Migliorini, I., & Annetta, M. G.
Venue
International Journal of Emergency Medicine
Published
2016-02-04
Volume
9
Issue
1
Pages
3-3
ISSN
  • 1865-1372 (ISSN-L)
  • 1865-1380
OpenAlex
W2265830224
Cited by
82
References
7
FWCI
12.02
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ultrasound-guided “short” midline catheters for difficult venous access in the emergency department: a retrospective analysis. https://app.cochat.ai/papers/10.1186/s12245-016-0100-0
The paper
Scoppettuolo, G., Pittiruti, M., Pitoni, S., Dolcetti, L., Emoli, A., Mitidieri, A., Migliorini, I., & Annetta, M. G. (2016). Ultrasound-guided “short” midline catheters for difficult venous access in the emergency department: a retrospective analysis. International Journal of Emergency Medicine. https://doi.org/10.1186/s12245-016-0100-0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.