CoChat

Ultrasound guidance for difficult peripheral venous access: systematic review and meta-analysis

Egan, Grace, Healy, Donagh, O'Neill, Heidi, Clarke-Moloney, Mary, Grace, Pierce A, Walsh, Stewart R · 2013 · Emergency Medicine Journal

The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.

Abstract

Background: Establishing intravenous access is often vital in an acute hospital setting but can be difficult. Ultrasound-guided cannulation increases success rates in prospective studies. However, these studies have often lacked a comparative group. This systematic review and meta-analysis aimed to determine the clinical effectiveness of Ultrasound-guided peripheral intravenous cannulation compared with the standard technique in patients known to have difficult access. Methods: Electronic abstract databases, trial registries, article reference lists and internet repositories were searched using the following search terms: ‘peripheral venous cannulation’, ‘peripheral venous access’. Studies meeting the following criteria were included: randomised controlled trial patients of all ages who required peripheral intravenous access; interventions were Ultrasound-guided versus standard cannulation technique; patients were identified as having difficult venous access; inclusion of at least one defined outcome (procedural success time to cannula placement; number of attempts). Results: 7 trials were identified (289 participants). Ultrasound guidance increases the likelihood of successful cannulation (pooled OR 2.42; 95% CI 1.26 to 4.68; p=0.008). There were no differences in time to successful cannulation, or number of percutaneous skin punctures. Conclusion: Ultrasound guidance increases the likelihood of successful peripheral cannulation in difficult access patients. We recommend its use in patients who have difficult venous access, and have failed venous cannulation by standard methods. Further randomised controlled trials (RCTs) with larger sample sizes would be of benefit to investigate if Ultrasound has any additional advantages in terms of reducing the procedure time and the number of skin punctures required for successful venous cannulation.

Overview

Integrity signals

Registry

Crossref · 10.1136/emermed-2012-201652

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 35 references

Cited by

See all 245

Metadata

Authors
Egan, G., Healy, D., O'Neill, H., Clarke-Moloney, M., Grace, P. A., & Walsh, S. R.
Affiliations
  • University of Limerick (IE)
  • University Hospital Limerick (IE)
  • Graduate Entry Medical School, University of Limerick, Limerick, Ireland
  • Vascular Research Unit, University Hospital Limerick, Limerick, Ireland
Venue
Emergency Medicine Journal
Publisher
BMJ
Published
2012-08-11
Volume
30
Issue
7
Pages
521-526
ISSN
  • 1351-0622 (ISSN-L)
  • 1472-0205
  • 1472-0213
OpenAlex
W2130305311
Cited by
222
References
35
Citations by year
2026: 9 · 2025: 13 · 2024: 9 · 2023: 29 · 2022: 21 · 2021: 20 · 2020: 23 · 2019: 27 · 2018: 18 · 2017: 10 · 2016: 17 · 2015: 13 · 2014: 7 · 2013: 4
FWCI
1.94
Type
journal article
Language
en
Open access
closed
Locations
  • Emergency Medicine Journal (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Central Venous Catheters and Hemodialysis
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Vascular Procedures and Complications
  • Physical Sciences › Engineering › Biomedical Engineering › Intravenous Infusion Technology and Safety
Keywords
ultrasound-guided cannulation, peripheral venous access, difficult venous access, peripheral venous cannulation, cannulation success rate, procedure time, emergency department
MeSH terms
Catheterization, Central Venous, Catheterization, Peripheral, Emergency Service, Hospital, Humans, Punctures, Time Factors, Reproducibility of Results, Randomized Controlled Trials as Topic, Treatment Outcome, Ultrasonography, Interventional

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ultrasound guidance for difficult peripheral venous access: systematic review and meta-analysis. https://app.cochat.ai/papers/10.1136/emermed-2012-201652
The paper
Egan, G., Healy, D., O'Neill, H., Clarke-Moloney, M., Grace, P. A., & Walsh, S. R. (2013). Ultrasound guidance for difficult peripheral venous access: systematic review and meta-analysis. Emergency Medicine Journal. https://doi.org/10.1136/emermed-2012-201652

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.