Cited by 41Tuberculosis Research and EpidemiologyDiagnosis and treatment of tuberculosisInfectious Diseases and Tuberculosis

Diagnostic accuracy of the Xpert MTB/Rif Ultra for tuberculosis adenitis

Open access
Antel, Katherine, Oosthuizen, Jenna, Malherbe, Francois, Louw, Vernon J., Nicol, Mark P., Maartens, Gary, Verburgh, Estelle·2020·BMC Infectious Diseases

Published version of a preprint

Abstract

BACKGROUND: The WHO recently recommended the new Xpert MTB/RIF Ultra assay (Ultra) instead of the Xpert MTB/RIF assay because Ultra has improved sensitivity. We report the diagnostic accuracy of Ultra for tuberculous adenitis in a tuberculosis and HIV endemic setting. METHODS: We obtained fine-needle aspirates (FNA) and lymph node tissue by core-needle biopsy in adult patients with peripheral lymphadenopathy of >20 mm. Ultra and mycobacterial culture were performed on FNA and tissue specimens, with histological examination of tissue specimens. We assessed the diagnostic accuracy of Ultra against a composite reference standard of 'definite tuberculosis' (microbiological criteria) or 'probable tuberculosis' (histological and clinical criteria). RESULTS: We prospectively evaluated 99 participants of whom 50 were HIV positive: 21 had 'definite tuberculosis', 15 'probable tuberculosis' and 63 did not have tuberculosis (of whom 38% had lymphoma and 19% disseminated malignancy). Using the composite reference standard the Ultra sensitivity on FNA was 70% (95% CI 51-85; 21 of 30), and on tissue was 67% (45-84; 16/24) these were far superior to the detection of acid-fast bacilli on an FNA (26%; 7/27); AFB on tissue (33%; 8/24); or tissue culture (39%; 9/23). The detection of granulomas on histology had high senstivity (83%) but the lowest specficity. When compared with culture the Ultra on FNA had a sensitvity of 78% (40-97; 7/9) and tissue 90% (55-100; 9/10). CONCLUSIONS: Ultra performed on FNA or tissue of a lymph node had good sensitivity and high specificity. Ultra had a higher yield than culture and has the advantage of being a rapid test. Ultra on FNA would be an appropriate initial investigation for lymphadenopathy in tuberculosis endemic areas followed by a core biopsy for histopathology with a repeat Ultra on tissue if granulomas are present.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s12879-019-4749-x

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In lymph node biopsies, Xpert Ultra sensitivity against a composite reference standard was 73% (50 to 89).

    “In lymph node biopsies, Xpert Ultra sensitivity and specificity against a composite reference standard were 73% (50 to 89) and 96% (88 to 100) (Antel 2020), (1 study; 81 participants); Figure 14.”

    From Xpert MTB/RIF Ultra and Xpert MTB/RIF assays for extrapulmonary tuberculosis and rifampicin resistance in adults (2021) · cites this paper as Antel 2020

    Table 3 in the Results reports sensitivity of 67% (95% CI 45–84; 16/24) for Ultra on lymph node tissue against the composite reference standard, not 73% (50–89). The table does match the citing sentence’s 81 participants and 96% specificity, although it gives the specificity interval as 88–99. (LLM, conf=0.90)

    Checked by a reasoning model — may be wrong.

    Experimental — accuracy not yet measured
  • In lymph node biopsies, Xpert Ultra specificity against a composite reference standard was 96% (88 to 100).

    “In lymph node biopsies, Xpert Ultra sensitivity and specificity against a composite reference standard were 73% (50 to 89) and 96% (88 to 100) (Antel 2020), (1 study; 81 participants); Figure 14.”

    From Xpert MTB/RIF Ultra and Xpert MTB/RIF assays for extrapulmonary tuberculosis and rifampicin resistance in adults (2021) · cites this paper as Antel 2020

    Table 3 (Results) reports 96% specificity for Ultra on lymph-node tissue in 81 participants against the composite reference standard. Its confidence interval is 88–99%, not the claimed 88–100%. (LLM, conf=0.91)

    Experimental — accuracy not yet measured
  • In lymph node biopsies, Xpert Ultra sensitivity against culture in Antel 2020 was 90% (55 to 100).

    “In lymph node biopsies, Xpert Ultra sensitivity and specificity against culture were 90% (55 to 100) and 87% (77 to 94) (Antel 2020) and 100% (75 to 100) and 38% (22 to 55) (Wu 2019), (2 studies; 131 participants, 23 (17.6%) with tuberculosis); Figure 14.”
  • In lymph node biopsies, Xpert Ultra specificity against culture in Antel 2020 was 87% (77 to 94).

    “In lymph node biopsies, Xpert Ultra sensitivity and specificity against culture were 90% (55 to 100) and 87% (77 to 94) (Antel 2020) and 100% (75 to 100) and 38% (22 to 55) (Wu 2019), (2 studies; 131 participants, 23 (17.6%) with tuberculosis); Figure 14.”
  • In lymph node aspirates, Xpert Ultra specificity against culture was 78% (66 to 87).

    “In lymph node aspirates, Xpert Ultra sensitivity and specificity against culture were 78% (40 to 97) and 78% (66 to 87), (1 study; 73 participants; 9 (12.3%) with tuberculosis; Antel 2020); Figure 13.”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

1 of the 22 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Antel, K., Oosthuizen, J., Malherbe, F., Louw, V. J., Nicol, M. P., Maartens, G., & Verburgh, E.
Affiliations
University of Cape Town (ZA)
Corresponding author
Antel, Katherine
Venue
BMC Infectious Diseases
Published
2020-01-13
Volume
20
Issue
1
Pages
33-33
ISSN
1471-2334 (ISSN-L)
OpenAlex
W3002483726
Cited by
41
References
22
Citations by year
2026: 5 · 2025: 5 · 2024: 6 · 2023: 7 · 2022: 5 · 2021: 7 · 2020: 6
FWCI
0.82
Type
journal article
Language
en
Open access
Locations
  • BMC Infectious Diseases (publishedVersion, cc-by)
  • Research Square (acceptedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
  • Open University of Cape Town (University of Cape Town) (submittedVersion)
  • UWA Profiles and Research Repository (UWA) (submittedVersion, cc-by)
Funders
  • Foundation for the National Institutes of Health (D43-TW010345)
  • National Institutes of Health (D43-TW010543])
  • National Research Foundation (119078)
Topics
  • Health Sciences › Medicine › Infectious Diseases › Tuberculosis Research and Epidemiology
  • Health Sciences › Medicine › Surgery › Diagnosis and treatment of tuberculosis
  • Health Sciences › Medicine › Surgery › Infectious Diseases and Tuberculosis
Keywords
Xpert MTB/RIF Ultra, tuberculous lymphadenitis, peripheral lymphadenopathy, diagnostic accuracy, sensitivity and specificity, HIV coinfection, fine-needle aspiration, core needle biopsy, mycobacterial culture, acid-fast bacilli, granuloma, tuberculosis diagnosis
MeSH terms
Data Accuracy, Adult, Diagnostic Tests, Routine, Female, HIV, HIV Seropositivity, Humans, Lymph Nodes, Male, Middle Aged, Mycobacterium tuberculosis, Probability, Prospective Studies, Sensitivity and Specificity, Tuberculosis, Lymph Node, Nucleic Acid Amplification Techniques, Biopsy, Fine-Needle

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review