CoChat

Robot-assisted thoracic surgery versus video-assisted thoracic surgery for lung lobectomy or segmentectomy in patients with non-small cell lung cancer: a meta-analysis

Open access
Ma, Jianglei, Li, Xiaoyao, Zhao, Shifu, Wang, Jiawei, Zhang, Wujia, Sun, Guangyuan · 2021 · BMC Cancer
Cited by 191

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

Abstract

Background: It remains no clear conclusion about which is better between robot-assisted thoracic surgery (RATS) and video-assisted thoracic surgery (VATS) for the treatment of patients with non-small cell lung cancer (NSCLC). Therefore, this meta-analysis aimed to compare the short-term and long-term efficacy between RATS and VATS for NSCLC. Methods: Pubmed, Cochrane Library, Embase, China National Knowledge Infrastructure (CNKI), Medline, and Web of Science databases were comprehensively searched for studies published before December 2020. The quality of the articles was evaluated using the Newcastle-Ottawa Scale (NOS) and the data analyzed using the Review Manager 5.3 software. Fixed or random effect models were applied according to heterogeneity. Subgroup analysis and sensitivity analysis were conducted. Results: A total of 18 studies including 11,247 patients were included in the meta-analyses, of which 5114 patients were in the RATS group and 6133 in the VATS group. Compared with VATS, RATS was associated with less blood loss (WMD = − 50.40, 95% CI -90.32 ~ − 10.48, P = 0.010), lower conversion rate (OR = 0.50, 95% CI 0.43 ~ 0.60, P < 0.001), more harvested lymph nodes (WMD = 1.72, 95% CI 0.63 ~ 2.81, P = 0.002) and stations (WMD = 0.51, 95% CI 0.15 ~ 0.86, P = 0.005), shorter duration of postoperative chest tube drainage (WMD = − 0.61, 95% CI -0.78 ~ − 0.44, P < 0.001) and hospital stay (WMD = − 1.12, 95% CI -1.58 ~ − 0.66, P < 0.001), lower overall complication rate (OR = 0.90, 95% CI 0.83 ~ 0.99, P = 0.020), lower recurrence rate (OR = 0.51, 95% CI 0.36 ~ 0.72, P < 0.001), and higher cost (WMD = 3909.87 USD, 95% CI 3706.90 ~ 4112.84, P < 0.001). There was no significant difference between RATS and VATS in operative time, mortality, overall survival (OS), and disease-free survival (DFS). Sensitivity analysis showed that no significant differences were found between the two techniques in conversion rate, number of harvested lymph nodes and stations, and overall complication. Conclusions: The results revealed that RATS is a feasible and safe technique compared with VATS in terms of short-term and long-term outcomes. Moreover, more randomized controlled trials comparing the two techniques with rigorous study designs are still essential to evaluate the value of robotic surgery for NSCLC.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s12885-021-08241-5

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Metadata

Authors
Ma, J., Li, X., Zhao, S., Wang, J., Zhang, W., & Sun, G.
Venue
BMC Cancer
Published
2021-05-03
Volume
21
Issue
1
Pages
498-498
ISSN
1471-2407 (ISSN-L)
OpenAlex
W3127368180
Cited by
191
References
26
FWCI
5.54
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Robot-assisted thoracic surgery versus video-assisted thoracic surgery for lung lobectomy or segmentectomy in patients with non-small cell lung cancer: a meta-analysis. https://app.cochat.ai/papers/10.1186/s12885-021-08241-5
The paper
Ma, J., Li, X., Zhao, S., Wang, J., Zhang, W., & Sun, G. (2021). Robot-assisted thoracic surgery versus video-assisted thoracic surgery for lung lobectomy or segmentectomy in patients with non-small cell lung cancer: a meta-analysis. BMC Cancer. https://doi.org/10.1186/s12885-021-08241-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.