Corneal biomechanical properties after SMILE versus FLEX, LASIK, LASEK, or PRK: a systematic review and meta-analysis
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
The aim of this study was to compare the postoperative corneal biomechanical properties between small incision lenticule extraction (SMILE) and other corneal refractive surgeries. A systematic review and meta-analysis were conducted. Articles from January 2005, to April 2019, were identified searching PubMed, EMBASE, Web of Science, and International Clinical Trials Registry Platform. Studies that compared SMILE with other corneal refractive surgeries on adult myopia patients and evaluated corneal biomechanics were included. Multiple effect sizes in each study were combined. Random-effects model was conducted in the meta-analysis. Twenty-two studies were included: 5 randomized controlled trials (RCTs), 9 prospective and 6 retrospective cohort studies, and 2 cross-sectional studies. Using the combined effect of corneal hysteresis (CH) and corneal resistance factor (CRF), which were obtained from ocular response analyzer (ORA), the pooled Hedges’ g of SMILE versus femtosecond laser-assisted in situ keratomileusis (FS-LASIK) was 0.41 (95% CI, 0.00 to 0.81; p = 0.049; I 2 = 78%), versus LASIK was 1.31 (95% CI, 0.54 to 2.08; p < 0.001; I 2 = 77%), versus femtosecond lenticule extraction (FLEX) was − 0.01 (95% CI, − 0.31 to 0.30; p = 0.972; I 2 = 20%), and versus the group of photorefractive keratectomy (PRK) and laser-assisted sub-epithelial keratectomy (LASEK) was − 0.26 (95% CI, − 0.67 to 0.16; p = 0.230; I 2 = 54%). The summary score of Corvis ST (CST) after SMILE was comparable to FS-LASIK/LASIK with the pooled Hedges’ g = − 0.05 (95% CI, − 0.24 to 0.14; p = 0.612, I 2 = 55%). In terms of preserving corneal biomechanical strength after surgeries, SMILE was superior to either FS-LASIK or LASIK, while comparable to FLEX or PRK/LASEK group based on the results from ORA. More studies are needed to apply CST on evaluating corneal biomechanics after refractive surgeries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & The PRISMA Group (2009) · PLoS Medicine · doi:10.1371/journal.pmed.1000097 · Cited by 64,042
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139
Quantifying heterogeneity in a meta‐analysis
Higgins, J. P. T., & Thompson, S. G. (2002) · Statistics in Medicine · doi:10.1002/sim.1186 · Cited by 36,763 · cited 1×
“Heterogeneity among studies was evaluated by χ 2 test and quantified using the I(2) statistics [42, 43].”
MethodBorenstein, M., Hedges, L. V., Higgins, J. P. T., & Rothstein, H. R. (2009) · doi:10.1002/9780470743386 · Cited by 14,225
Borenstein, M., Hedges, L. V., Higgins, J. P. T., & Rothstein, H. R. (2021) · doi:10.1002/9781119558378 · Cited by 9,799
Downs, S. H., & Black, N. (1998) · Journal of Epidemiology and Community Health · doi:10.1136/jech.52.6.377 · Cited by 8,252 · cited 1×
“Quality assessment We used Downs and Black checklist to assess literature quality, which includes reporting bias, external validity, information bias, selection bias, and power [27].”
MethodDistribution Theory for Glass's Estimator of Effect Size and Related Estimators
Hedges, L. V. (1981) · Journal of Educational Statistics · doi:10.2307/1164588 · Cited by 5,695 · cited 1×
“The effect sizes of the biomechanical outcomes achieved from ORA and CST were calculated with standardized mean difference (Hedges’ g) [32].”
MethodChapter 9: Analysing Data and Undertaking Meta-Analyses
Deeks, J. J., Higgins, J. P. T., & Altman, D. G. (2008) · Cited by 2,782
Reprint—Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & and the PRISMA Group (2009) · Physical Therapy · doi:10.1093/ptj/89.9.873 · Cited by 2,486
Metadata
- Authors
- Guo, H., Hosseini-Moghaddam, S. M., & Hodge, W.
- Venue
- BMC Ophthalmology
- Published
- 2019-08-01
- Volume
- 19
- Issue
- 1
- Pages
- 167-167
- ISSN
- 1471-2415 (ISSN-L)
- OpenAlex
- W2965514200
- Cited by
- 159
- References
- 32
- FWCI
- 3.52
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Corneal biomechanical properties after SMILE versus FLEX, LASIK, LASEK, or PRK: a systematic review and meta-analysis. https://app.cochat.ai/papers/10.1186/s12886-019-1165-3
- The paper
- Guo, H., Hosseini-Moghaddam, S. M., & Hodge, W. (2019). Corneal biomechanical properties after SMILE versus FLEX, LASIK, LASEK, or PRK: a systematic review and meta-analysis. BMC Ophthalmology. https://doi.org/10.1186/s12886-019-1165-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.