The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: a comparative in vitro study
Open accessAbstract
BACKGROUND: Until now, a few studies have addressed the accuracy of intraoral scanners (IOSs) in implantology. Hence, the aim of this in vitro study was to assess the accuracy of 5 different IOSs in the impressions of single and multiple implants, and to compare them. METHODS: Plaster models were prepared, representative of a partially edentulous maxilla (PEM) to be restored with a single crown (SC) and a partial prosthesis (PP), and a totally edentulous maxilla (TEM) to be restored with a full-arch (FA). These models were scanned with a desktop scanner, to capture reference models (RMs), and with 5 IOSs (CS 3600®, Trios3®, Omnicam®, DWIO®, Emerald®); 10 scans were taken for each model, using each IOS. All IOS datasets were loaded into a reverse-engineering software where they were superimposed on the corresponding RMs, to evaluate trueness, and superimposed on each other within groups, to determine precision. A statistical analysis was performed. RESULTS: In the SC, CS 3600® had the best trueness (15.2 ± 0.8 μm), followed by Trios3® (22.3 ± 0.5 μm), DWIO® (27.8 ± 3.2 μm), Omnicam® (28.4 ± 4.5 μm), Emerald® (43.1 ± 11.5 μm). In the PP, CS 3600® had the best trueness (23 ± 1.1 μm), followed by Trios3® (28.5 ± 0.5 μm), Omnicam® (38.1 ± 8.8 μm), Emerald® (49.3 ± 5.5 μm), DWIO® (49.8 ± 5 μm). In the FA, CS 3600® had the best trueness (44.9 ± 8.9 μm), followed by Trios3® (46.3 ± 4.9 μm), Emerald® (66.3 ± 5.6 μm), Omnicam® (70.4 ± 11.9 μm), DWIO® (92.1 ± 24.1 μm). Significant differences were found between the IOSs; a significant difference in trueness was found between the contexts (SC vs. PP vs. FA). In the SC, CS 3600® had the best precision (11.3 ± 1.1 μm), followed by Trios3® (15.2 ± 0.8 μm), DWIO® (27.1 ± 10.7 μm), Omnicam® (30.6 ± 3.3 μm), Emerald® (32.8 ± 10.7 μm). In the PP, CS 3600® had the best precision (17 ± 2.3 μm), followed by Trios3® (21 ± 1.9 μm), Emerald® (29.9 ± 8.9 μm), DWIO® (34.8 ± 10.8 μm), Omnicam® (43.2 ± 9.4 μm). In the FA, Trios3® had the best precision (35.6 ± 3.4 μm), followed by CS 3600® (35.7 ± 4.3 μm), Emerald® (61.5 ± 18.1 μm), Omnicam® (89.3 ± 14 μm), DWIO® (111 ± 24.8 μm). Significant differences were found between the IOSs; a significant difference in precision was found between the contexts (SC vs. PP vs. FA). CONCLUSIONS: The IOSs showed significant differences between them, both in trueness and in precision. The mathematical error increased in the transition from SC to PP up to FA, both in trueness than in precision.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Applications of polyetheretherketone (PEEK) in oral implantology and prosthodontics
Najeeb, S., Zafar, M. S., Khurshid, Z., & Siddiqui, F. (2016) · Journal of Prosthodontic Research · doi:10.1016/j.jpor.2015.10.001 · Cited by 897
The complete digital workflow in fixed prosthodontics: a systematic review
Joda, T., Zarone, F., & Ferrari, M. (2017) · BMC Oral Health · doi:10.1186/s12903-017-0415-0 · Cited by 426
Accuracy of four intraoral scanners in oral implantology: a comparative in vitro study
Imburgia, M., Logozzo, S., Hauschild, U., Veronesi, G., Mangano, C., & Mangano, F. G. (2017) · BMC Oral Health · doi:10.1186/s12903-017-0383-4 · Cited by 393
Self-citationApplication of Intra-Oral Dental Scanners in the Digital Workflow of Implantology
van der Meer, W. J., Andriessen, F. S., Wismeijer, D., & Ren, Y. (2012) · PLoS ONE · doi:10.1371/journal.pone.0043312 · Cited by 265
Accuracy of five intraoral scanners compared to indirect digitalization
Güth, J.-F., Runkel, C., Beuer, F., Stimmelmayr, M., Edelhoff, D., & Keul, C. (2017) · Clinical Oral Investigations · doi:10.1007/s00784-016-1902-4 · Cited by 195
Mühlemann, S., Kraus, R. D., Hämmerle, C. H. F., & Thoma, D. S. (2018) · Clinical Oral Implants Research · doi:10.1111/clr.13300 · Cited by 114
Joda, T., Ferrari, M., & Brägger, U. (2017) · Clinical Implant Dentistry and Related Research · doi:10.1111/cid.12472 · Cited by 102
Mangano, F. G., Margiani, B., & Admakin, O. I. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16030317 · Cited by 50
Self-citationJoda, T., Ferrari, M., Brägger, U., & Zitzmann, N. U. (2018) · Clinical Oral Implants Research · doi:10.1111/clr.13360 · Cited by 38
Cited by
Mangano, C., Bianchi, A., Mangano, F. G., Dana, J., Colombo, M., Solop, I., & Admakin, O. (2020) · 3D Printing in Medicine · doi:10.1186/s41205-019-0055-x · Cited by 119
Self-citation
Metadata
- Authors
- Mangano, F. G., Hauschild, U., Veronesi, G., Imburgia, M., Mangano, C., & Admakin, O.
- Venue
- BMC Oral Health
- Published
- 2019-06-06
- Volume
- 19
- Issue
- 1
- Pages
- 101-101
- ISSN
- 1472-6831 (ISSN-L)
- OpenAlex
- W2948864212
- Cited by
- 259
- References
- 9
- FWCI
- 29.03
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: a comparative in vitro study. https://app.cochat.ai/papers/10.1186/s12903-019-0792-7
- The paper
- Mangano, F. G., Hauschild, U., Veronesi, G., Imburgia, M., Mangano, C., & Admakin, O. (2019). Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: a comparative in vitro study. BMC Oral Health. https://doi.org/10.1186/s12903-019-0792-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.