The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Application of Intra-Oral Dental Scanners in the Digital Workflow of Implantology
Open accessAbstract
UNLABELLED: Intra-oral scanners will play a central role in digital dentistry in the near future. In this study the accuracy of three intra-oral scanners was compared. MATERIALS AND METHODS: A master model made of stone was fitted with three high precision manufactured PEEK cylinders and scanned with three intra-oral scanners: the CEREC (Sirona), the iTero (Cadent) and the Lava COS (3M). In software the digital files were imported and the distance between the centres of the cylinders and the angulation between the cylinders was assessed. These values were compared to the measurements made on a high accuracy 3D scan of the master model. RESULTS: The distance errors were the smallest and most consistent for the Lava COS. The distance errors for the Cerec were the largest and least consistent. All the angulation errors were small. CONCLUSIONS: The Lava COS in combination with a high accuracy scanning protocol resulted in the smallest and most consistent errors of all three scanners tested when considering mean distance errors in full arch impressions both in absolute values and in consistency for both measured distances. For the mean angulation errors, the Lava COS had the smallest errors between cylinders 1-2 and the largest errors between cylinders 1-3, although the absolute difference with the smallest mean value (iTero) was very small (0,0529°). An expected increase in distance and/or angular errors over the length of the arch due to an accumulation of registration errors of the patched 3D surfaces could be observed in this study design, but the effects were statistically not significant. CLINICAL RELEVANCE: For making impressions of implant cases for digital workflows, the most accurate scanner with the scanning protocol that will ensure the most accurate digital impression should be used. In our study model that was the Lava COS with the high accuracy scanning protocol.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A method for registration of 3-D shapes
Besl, P. J., & McKay, N. D. (1992) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.121791 · Cited by 18,103
IEEE Transactions on Pattern Analysis and Machine Intelligence
(2004) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2004.1307293 · Cited by 3,721
A survey of medical image registration
Maintz, J. B. A., & Viergever, M. A. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80026-8 · Cited by 3,327
Object modelling by registration of multiple range images
Chen, Y., & Medioni, G. (1992) · Image and Vision Computing · doi:10.1016/0262-8856(92)90066-c · Cited by 3,154
Osseointegration and its experimental background
Branemark, P.-I. (1983) · The Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(83)80101-2 · Cited by 2,084
Object modeling by registration of multiple range images
Chen, Y., & Medioni, G. (2002) · Proceedings. 1991 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.1991.132043 · Cited by 1,409
Occlusal considerations in implant therapy: clinical guidelines with biomechanical rationale
Kim, Y., Oh, T., Misch, C. E., & Wang, H. (2004) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2004.01067.x · Cited by 658
Syrek, A., Reich, G., Ranftl, D., Klein, C., Cerny, B., & Brodesser, J. (2010) · Journal of Dentistry · doi:10.1016/j.jdent.2010.03.015 · Cited by 390
3-D Modeling of Real-World Objects Using Range and Intensity Images
Park, J., & DeSouza, G. N. (2005) · Studies in computational intelligence · doi:10.1007/11504634_6 · Cited by 24
Cited by
Accuracy of four intraoral scanners in oral implantology: a comparative in vitro study
Imburgia, M., Logozzo, S., Hauschild, U., Veronesi, G., Mangano, C., & Mangano, F. G. (2017) · BMC Oral Health · doi:10.1186/s12903-017-0383-4 · Cited by 393
Mangano, F. G., Hauschild, U., Veronesi, G., Imburgia, M., Mangano, C., & Admakin, O. (2019) · BMC Oral Health · doi:10.1186/s12903-019-0792-7 · Cited by 259
Metadata
- Authors
- van der Meer, W. J., Andriessen, F. S., Wismeijer, D., & Ren, Y.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2012-08-22
- Volume
- 7
- Issue
- 8
- Pages
- e43312
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2137403833
- Cited by
- 265
- References
- 9
- FWCI
- 18.36
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Application of Intra-Oral Dental Scanners in the Digital Workflow of Implantology. https://app.cochat.ai/papers/10.1371/journal.pone.0043312
- The paper
- van der Meer, W. J., Andriessen, F. S., Wismeijer, D., & Ren, Y. (2012). Application of Intra-Oral Dental Scanners in the Digital Workflow of Implantology. PLoS ONE. https://doi.org/10.1371/journal.pone.0043312
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.