CoChat

Comparison of RetinaNet, SSD, and YOLO v3 for real-time pill identification

Open access
Tan, Lu, Huangfu, Tianran, Wu, Liyao, Chen, Wenying · 2021 · BMC Medical Informatics and Decision Making
Cited by 224

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

Background: The correct identification of pills is very important to ensure the safe administration of drugs to patients. Here, we use three current mainstream object detection models, namely RetinaNet, Single Shot Multi-Box Detector (SSD), and You Only Look Once v3(YOLO v3), to identify pills and compare the associated performance. Methods: In this paper, we introduce the basic principles of three object detection models. We trained each algorithm on a pill image dataset and analyzed the performance of the three models to determine the best pill recognition model. The models were then used to detect difficult samples and we compared the results. Results: The mean average precision (MAP) of RetinaNet reached 82.89%, but the frames per second (FPS) is only one third of YOLO v3, which makes it difficult to achieve real-time performance. SSD does not perform as well on the indicators of MAP and FPS. Although the MAP of YOLO v3 is slightly lower than the others (80.69%), it has a significant advantage in terms of detection speed. YOLO v3 also performed better when tasked with hard sample detection, and therefore the model is more suitable for deployment in hospital equipment. Conclusion: Our study reveals that object detection can be applied for real-time pill identification in a hospital pharmacy, and YOLO v3 exhibits an advantage in detection speed while maintaining a satisfactory MAP.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s12911-021-01691-8

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 4

  1. Chang CH, Lai YL, Chen CC. Implement the RFID position based system of automatic tablets packaging machine for patient safety. J Med Syst. 2012;36(6):3463–71. · doi:10.1007/s10916-011-9799-6
  2. Zheng S, Zhang W, Wang L, et al. Special shaped softgel inspection system based on machine vision. In: 2015 IEEE 9th international conference on Anti-counterfeiting, Security, and Identification (ASID). IEEE; 2015. p. 124–7. https://doi.org/10.1109/ICASID.2015.7405675. · doi:10.1109/icasid.2015.7405675
  3. Lee YB, Park U, Jain AK. Pill-id: matching and retrieval of drug pill imprint images. In: 2010 20th international conference on pattern recognition. IEEE; 2010. p. 2632–5. https://doi.org/10.1109/ICPR.2010.645. · doi:10.1109/icpr.2010.645
  4. Morimoto M, Fujii K. A visual inspection system for drug tablets. In: 2011 IEEE international conference on systems, man, and cybernetics. IEEE; 2011. p. 1106–10. https://doi.org/10.1109/ICSMC.2011.6083822. · doi:10.1109/icsmc.2011.6083822

Cited by

See all 224

Metadata

Authors
Tan, L., Huangfu, T., Wu, L., & Chen, W.
Venue
BMC Medical Informatics and Decision Making
Published
2021-11-22
Volume
21
Issue
1
Pages
324-324
ISSN
1472-6947 (ISSN-L)
OpenAlex
W3215073785
Cited by
224
References
20
FWCI
12.52
Type
journal article
Language
en
Open access
gold
Licence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.