Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 202

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Delirium detection in older acute medical inpatients: a multicentre prospective comparative diagnostic test accuracy study of the 4AT and the confusion assessment method

Open access
Shenkin, Susan D., Fox, Christopher, Godfrey, Mary, Siddiqi, Najma, Goodacre, Steve, Young, John, Anand, Atul, Gray, Alasdair, Hanley, Janet, MacRaild, Allan, Steven, Jill, Black, Polly L., Tieges, Zoë, Boyd, Julia, Stephen, Jacqueline, Weir, Christopher J., MacLullich, Alasdair M. J.·2019·BMC Medicine

Abstract

BACKGROUND: Delirium affects > 15% of hospitalised patients but is grossly underdetected, contributing to poor care. The 4 'A's Test (4AT, www.the4AT.com ) is a short delirium assessment tool designed for routine use without special training. The primary objective was to assess the accuracy of the 4AT for delirium detection. The secondary objective was to compare the 4AT with another commonly used delirium assessment tool, the Confusion Assessment Method (CAM). METHODS: This was a prospective diagnostic test accuracy study set in emergency departments or acute medical wards involving acute medical patients aged ≥ 70. All those without acutely life-threatening illness or coma were eligible. Patients underwent (1) reference standard delirium assessment based on DSM-IV criteria and (2) were randomised to either the index test (4AT, scores 0-12; prespecified score of > 3 considered positive) or the comparator (CAM; scored positive or negative), in a random order, using computer-generated pseudo-random numbers, stratified by study site, with block allocation. Reference standard and 4AT or CAM assessments were performed by pairs of independent raters blinded to the results of the other assessment. RESULTS: Eight hundred forty-three individuals were randomised: 21 withdrew, 3 lost contact, 32 indeterminate diagnosis, 2 missing outcome, and 785 were included in the analysis. Mean age was 81.4 (SD 6.4) years. 12.1% (95/785) had delirium by reference standard assessment, 14.3% (56/392) by 4AT, and 4.7% (18/384) by CAM. The 4AT had an area under the receiver operating characteristic curve of 0.90 (95% CI 0.84-0.96). The 4AT had a sensitivity of 76% (95% CI 61-87%) and a specificity of 94% (95% CI 92-97%). The CAM had a sensitivity of 40% (95% CI 26-57%) and a specificity of 100% (95% CI 98-100%). CONCLUSIONS: The 4AT is a short, pragmatic tool which can help improving detection rates of delirium in routine clinical care. TRIAL REGISTRATION: International standard randomised controlled trial number (ISRCTN) 53388093 . Date applied 30/05/2014; date assigned 02/06/2014.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s12916-019-1367-9

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 202

Metadata

Authors
Shenkin, S. D., Fox, C., Godfrey, M., Siddiqi, N., Goodacre, S., Young, J., Anand, A., Gray, A., Hanley, J., MacRaild, A., Steven, J., Black, P. L., Tieges, Z., Boyd, J., Stephen, J., Weir, C. J., & MacLullich, A. M. J.
Venue
BMC Medicine
Published
2019-07-24
Volume
17
Issue
1
Pages
138-138
ISSN
1741-7015 (ISSN-L)
OpenAlex
W2949453524
Cited by
202
References
4
FWCI
19.58
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Delirium detection in older acute medical inpatients: a multicentre prospective comparative diagnostic test accuracy study of the 4AT and the confusion assessment method. https://app.cochat.ai/papers/10.1186/s12916-019-1367-9
The paper
Shenkin, S. D., Fox, C., Godfrey, M., Siddiqi, N., Goodacre, S., Young, J., Anand, A., Gray, A., Hanley, J., MacRaild, A., Steven, J., Black, P. L., Tieges, Z., Boyd, J., Stephen, J., Weir, C. J., & MacLullich, A. M. J. (2019). Delirium detection in older acute medical inpatients: a multicentre prospective comparative diagnostic test accuracy study of the 4AT and the confusion assessment method. BMC Medicine. https://doi.org/10.1186/s12916-019-1367-9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.