Temporal fluctuations of tremor signals from inertial sensor: a preliminary study in differentiating Parkinson’s disease from essential tremor

Open access

Abstract

BACKGROUND: Parkinson's disease (PD) and essential tremor (ET) are the two most common movement disorders but the rate of misdiagnosis rate in these disorders is high due to similar characteristics of tremor. The purpose of the study is to present: (a) a solution to identify PD and ET patients by using the novel measurement of tremor signal variations while performing the resting task, (b) the improvement of the differentiation of PD from ET patients can be obtained by using the ratio of the novel measurement while performing two specific tasks. METHODS: 35 PD and 22 ET patients were asked to participate in the study. They were asked to wear a 6-axis inertial sensor on his/her index finger of the tremor dominant hand and perform three tasks including kinetic, postural and resting tasks. Each task required 10 s to complete. The angular rate signal measured during the performance of these tasks was band-pass filtered and transformed into a two-dimensional representation. The ratio of the ellipse area covering 95 % of this two-dimensional representation of different tasks was investigated and the two best tasks were selected for the purpose of differentiation. RESULTS: The ellipse area of two-dimensional representation of the resting task of PD and ET subjects are statistically significantly different (p < 0.05). Furthermore, the fluctuation ratio, defined as a ratio of the ellipse area of two-dimensional representation of resting to kinetic tremor, of PD subjects were statistically significantly higher than ET subjects in all axes (p = 0.0014, 0.0011 and 0.0001 for x, y and z-axis, respectively). The validation shows that the proposed method provides 100 % sensitivity, specificity and accuracy of the discrimination in the 5 subjects in the validation group. While the method would have to be validated with a larger number of subjects, these preliminary results show the feasibility of the approach. CONCLUSIONS: This study provides the novel measurement of tremor variation in time domain termed 'temporal fluctuation'. The temporal fluctuation of the resting task can be used to discriminate PD from ET subjects. The ratio of the temporal fluctuation of the resting task to the kinetic task improves the reliability of the discrimination. While the method is powerful, it is also simple so it could be applied on low resource platforms such as smart phones and watches which are commonly equipped with inertial sensors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s12938-015-0098-1

Cites

Statistics

Figures

Fig. 1 System set-up including a sensor unit and the transmitter, connected by a thin wire, and the axis orientation of an angular rate sensor
Fig. 1 System set-up including a sensor unit and the transmitter, connected by a thin wire, and the axis orientation of an angular rate sensorCC BY · PubMed Central
Fig. 2 Tremor signal of a PD subject while performing kinetic, postural and resting tasks in x (a), y (b) and z-axis (c) and the corresponding preprocessed tremor signal (d–f). Subject was randomly selected
Fig. 2 Tremor signal of a PD subject while performing kinetic, postural and resting tasks in x (a), y (b) and z-axis (c) and the corresponding preprocessed tremor signal (d–f). Subject was randomly selectedCC BY · PubMed Central
Fig. 3 Tremor signal of an ET subject while performing kinetic, postural and resting tasks in x (a), y (b) and z-axis (c) and the corresponding preprocessed tremor signal (d), (e) and (f). Subject was randomly selected
Fig. 3 Tremor signal of an ET subject while performing kinetic, postural and resting tasks in x (a), y (b) and z-axis (c) and the corresponding preprocessed tremor signal (d), (e) and (f). Subject was randomly selectedCC BY · PubMed Central
Fig. 4 Average tremor peak frequencies of the training group, 32 PD (a) and 20 ET (b) subjects, while performing kinetic (cross), postural (star) and resting (square) task. Average peak frequency is the mean value of peak frequencies obtained from power spectral density of ten tremor subsequences. The power spectral density was obtained parametrically by autoregressive (AR) model parameters using Yule–Walker method
Fig. 4 Average tremor peak frequencies of the training group, 32 PD (a) and 20 ET (b) subjects, while performing kinetic (cross), postural (star) and resting (square) task. Average peak frequency is the mean value of peak frequencies obtained from power spectral density of ten tremor subsequences. The power spectral density was obtained parametrically by autoregressive (AR) model parameters using Yule–Walker methodCC BY · PubMed Central
Fig. 5 Two-dimensional plot of relation (1) of tremor signal obtained while performing kinetic (cross) and resting (circle) tasks from a PD (a) and an ET (b) patient. Both are males with 77 years of ages and 7 years of disease duration. Delay units d 1 and d 2 in relation (1) were involuntarily selected to 5 and 20, respectively. The temporal fluctuation of tremor is the area of 95 % confidence ellipse covering the two-dimensional representation of kinetic (filled line) and resting (dash line) task
Fig. 5 Two-dimensional plot of relation (1) of tremor signal obtained while performing kinetic (cross) and resting (circle) tasks from a PD (a) and an ET (b) patient. Both are males with 77 years of ages and 7 years of disease duration. Delay units d 1 and d 2 in relation (1) were involuntarily selected to 5 and 20, respectively. The temporal fluctuation of tremor is the area of 95 % confidence ellipse covering the two-dimensional representation of kinetic (filled line) and resting (dash line) taskCC BY · PubMed Central
Fig. 6 The temporal fluctuation of the training group, 32 PD (a) and 20 ET (b) subjects, while performing kinetic (plus) and resting (circle) tasks. Delay units d 1 and d 2 in relation (1) were involuntarily selected to 5 and 20, respectively. The temporal fluctuation is shown in log scale
Fig. 6 The temporal fluctuation of the training group, 32 PD (a) and 20 ET (b) subjects, while performing kinetic (plus) and resting (circle) tasks. Delay units d 1 and d 2 in relation (1) were involuntarily selected to 5 and 20, respectively. The temporal fluctuation is shown in log scaleCC BY · PubMed Central
Fig. 7 The fluctuation ratio with delay unit d 1 = 5 samples and d 2 = 20 samples in relation (1) of the training group, 32 PD (star) and 20 ET (circle) subjects. The fluctuation ratio is a log scale of percentage of temporal fluctuation while performing resting task to kinetic task of an individual subject. The log scale is used because the distribution of percentage of temporal fluctuation while performing resting task to kinetic task is skew
Fig. 7 The fluctuation ratio with delay unit d 1 = 5 samples and d 2 = 20 samples in relation (1) of the training group, 32 PD (star) and 20 ET (circle) subjects. The fluctuation ratio is a log scale of percentage of temporal fluctuation while performing resting task to kinetic task of an individual subject. The log scale is used because the distribution of percentage of temporal fluctuation while performing resting task to kinetic task is skewCC BY · PubMed Central
Fig. 8 The distribution of fluctuation ratios of the training group, 32 PD and 20 ET subjects, obtained from x, y and z axis of angular rate sensor
Fig. 8 The distribution of fluctuation ratios of the training group, 32 PD and 20 ET subjects, obtained from x, y and z axis of angular rate sensorCC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

The citation lists are queued

They are fetched later and appear here then.

References 24 · Cited by 35

Metadata

Authors
Thanawattano, C., Pongthornseri, R., Anan, C., Dumnin, S., & Bhidayasiri, R.
Affiliations
  • National Science and Technology Development Agency (TH)
  • Thai Red Cross Society (TH)
Corresponding author
Thanawattano, Chusak
Venue
BioMedical Engineering OnLine
Published
2015-11-04
Volume
14
Issue
1
Pages
101-101
ISSN
1475-925X (ISSN-L)
OpenAlex
W1952234661
Cited by
35
References
24
Citations by year
2025: 2 · 2024: 5 · 2023: 3 · 2022: 5 · 2021: 5 · 2020: 1 · 2019: 1 · 2018: 5 · 2017: 5 · 2016: 3
FWCI
3.06
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • BioMedical Engineering OnLine (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Greater South Information System
Funders
The Ratchadapiseksompoj Endowment Fund of Chulalongkorn University (GRU-58-010-30-001)
Topics
  • Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
  • Health Sciences › Medicine › Clinical Neurology › Parkinson's Disease Mechanisms and Treatments
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
Keywords
Parkinson's disease, essential tremor, temporal fluctuations, inertial sensors, resting tremor, kinetic tremor, postural tremor, disease discrimination, ellipse area, smartphone-based diagnostics
MeSH terms
Aged, Diagnosis, Differential, Female, Humans, Male, Middle Aged, Parkinson Disease, Time Factors, Tremor, Essential Tremor, Electrical Equipment and Supplies

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Temporal fluctuations of tremor signals from inertial sensor: a preliminary study in differentiating Parkinson’s disease from essential tremor. https://app.cochat.ai/papers/10.1186/s12938-015-0098-1
The paper
Thanawattano, C., Pongthornseri, R., Anan, C., Dumnin, S., & Bhidayasiri, R. (2015). Temporal fluctuations of tremor signals from inertial sensor: a preliminary study in differentiating Parkinson’s disease from essential tremor. BioMedical Engineering OnLine. https://doi.org/10.1186/s12938-015-0098-1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.