Differential diagnosis between Parkinson's disease and essential tremor using the smartphone's accelerometer
Open accessThe DOI matches its Crossref record; 22 of the 23 references it cites were found in a registry or an index; 3 of the 20 sources its claims cite were checked for support.
Abstract
BACKGROUND: The differential diagnosis between patients with essential tremor (ET) and those with Parkinson's disease (PD) whose main manifestation is tremor may be difficult unless using complex neuroimaging techniques such as 123I-FP-CIT SPECT. We considered that using smartphone's accelerometer to stablish a diagnostic test based on time-frequency differences between PD an ET could support the clinical diagnosis. METHODS: The study was carried out in 17 patients with PD, 16 patients with ET, 12 healthy volunteers and 7 patients with tremor of undecided diagnosis (TUD), who were re-evaluated one year after the first visit to reach the definite diagnosis. The smartphone was placed over the hand dorsum to record epochs of 30 s at rest and 30 s during arm stretching. We generated frequency power spectra and calculated receiver operating characteristics curves (ROC) curves of total spectral power, to establish a threshold to separate subjects with and without tremor. In patients with PD and ET, we found that the ROC curve of relative energy was the feature discriminating better between the two groups. This threshold was then used to classify the TUD patients. RESULTS: We could correctly classify 49 out of 52 subjects in the category with/without tremor (97.96% sensitivity and 83.3% specificity) and 27 out of 32 patients in the category PD/ET (84.38% discrimination accuracy). Among TUD patients, 2 of 2 PD and 2 of 4 ET were correctly classified, and one patient having PD plus ET was classified as PD. CONCLUSIONS: Based on the analysis of smartphone accelerometer recordings, we found several kinematic features in the analysis of tremor that distinguished first between healthy subjects and patients and, ultimately, between PD and ET patients. The proposed method can give immediate results for the clinician to gain valuable information for the diagnosis of tremor. This can be useful in environments where more sophisticated diagnostic techniques are unavailable.
Overview
CoChat Summary
## TL;DR
This prospective study tested whether a smartphone’s accelerometer could help distinguish Parkinson’s disease (PD) tremor from essential tremor (ET) using short recordings at rest and in posture. The approach achieved 84.38% discrimination accuracy for PD vs ET, and the authors argue it could provide rapid support for clinical diagnosis when more advanced tests are unavailable.
## Key findings
- In the first classification step, total spectral power separated tremulous patients from healthy subjects with 97.96% sensitivity and 83.3% specificity; ROC-AUC was 90.6% for Rest and 96.7% for Posture.
- For PD vs ET, the best discriminative feature was Relative Energy (RE), with a threshold of 0.21 and ROC-AUC of 89.8%; this classified 27 of 32 patients correctly, for 84.38% discrimination accuracy.
- For the second feature, Relative Power Contribution (RPC) in posture, the threshold was 0.125 with ROC-AUC 74.9%; median RPC in posture was 0.25 in PD vs 0.10 in ET (p = 0.014).
- Among the 7 tremor of undecided diagnosis (TUD) patients, 2 of 2 PD and 2 of 4 ET were correctly classified, and 1 patient with PD plus ET was classified as PD.
## Methods
- Prospective tremor analysis study at the Movement Disorder Unit of Hospital Clinic of Barcelona, conducted between October 2015 and December 2016; recordings took less than 3 minutes per subject.
- Sample initially included 17 PD, 17 ET, 7 TUD, and 13 healthy subjects; after exclusions, analyses used 40 patients and 12 healthy subjects, with 32 PD/ET patients in the PD-vs-ET analysis.
- A smartphone (iPhone 5S) accelerometer recorded 30 s at rest and 30 s during arm stretching/posture; data were processed with Welch power spectra and analyzed with ROC curves, Mann-Whitney U tests, and blinded analysis of signal features.
## Limitations
- The authors state that the cut-off values were developed for their own sample and “should be checked in future studies”; they also call for a larger, multicentre study to improve generalizability.
- They note the TUD sample was too small to draw firm conclusions.
- Evident from the text: many participants were on medication and some ET patients had deep brain stimulation, which may have lowered tremor intensity and contributed to misclassification; the authors explicitly suggest this may limit performance for very mild tremor.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
2 Valid · 1 Not valid · 7 Not checked · 29 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“In fact, previous studies have shown that smartphone accelerometers are comparable to laboratory accelerometers in the assessment and classification of tremors [6–10]”
§ Differential diagnosis between Parkinson's disease and essential tremor using the smartphone's accelerometer > Introduction
What the sources say
- Partly supportedcites [6] J-F Daneault, 2012, Using a smart phone as a standalone platform for detection and monitoring of pathological tremors, Front Hum Neurosci sourceExperimental — accuracy not yet measured
The Discussion (‘Validation against laboratory tools’) says the smartphone produced results similar to laboratory tools for tremor measurements, but with limitations: spectral measures required tremor amplitude above 1 mm and were unreliable during movement. The Results compare measured tremor characteristics across pre-specified tasks; they do not establish that the smartphone classified tremors comparably to a laboratory accelerometer. Page numbers were not available in our copy. (LLM, conf=0.87)
- Not checked — no full text of the sourcecites [7] N Kostikis, 2015, A Smartphone-Based Tool for Assessing Parkinsonian Hand Tremor, IEEE J Biomed Heal informatics source
- Not checked — no full text of the sourcecites [8] RA Joundi, 2011, Rapid tremor frequency assessment with the iPhone accelerometer, Park Relat Disord source
- Not checked — no full text of the sourcecites [9] Kostikis N, Hristu-Varsakelis D, Arnaoutoglou M, Kotsavasiloglou C. Smartphone-based evaluation of parkinsonian hand tremor: Quantitative measurements vs clinical assessment scores. 36th Annu Int Conf IEEE Eng Med Biol Soc EMBC 2014. 2014;906–9 source
- Not checked — no full text of the sourcecites [10] S Senova, 2015, Using the accelerometers integrated in smartphones to evaluate essential tremor, Stereotact Funct Neurosurg source
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“ROC-AUC was 90.6% (95% confidence interval: 86.0–95.2) for Rest and 96.7% (94.5–98.9) for Posture.”
§ Differential diagnosis between Parkinson's disease and essential tremor using the smartphone's accelerometer > Results > Part 1: Discrimination between patients with tremor and healthy subjects
plainn = 40- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“In patients with PD and ET, we found that the ROC curve of relative energy was the feature discriminating better between the two groups.”
§ Differential diagnosis between Parkinson's disease and essential tremor using the smartphone's accelerometer > Abstract > Methods
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on an assumption not shown here.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“However, significant differences were found for the analysis of RPC in Posture, with median values of 0.25, IQR 0.15–0.41 for PD and 0.10, IQR 0.08–0.11 for ET (p = 0.014)”
§ Differential diagnosis between Parkinson's disease and essential tremor using the smartphone's accelerometer > Results > Part 2: Discrimination between PD and ET
plainstates an associationn = 32 ·- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Total spectral power in Posture significantly differed (p-value <0.001) between patients with tremor (median 1.4 mg2·s, IQR 0.09–6.5) and healthy subjects (median 0.1 mg2·s, IQR 0.08–0.2).”
§ Differential diagnosis between Parkinson's disease and essential tremor using the smartphone's accelerometer > Results > Part 1: Discrimination between patients with tremor and healthy subjects
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
17 more claims
Create a free account to see all 39 claims and every source verdict.
- It may state two separate claims as one. 14
- Probably not a substantial claim. 5
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“A number of initial studies suggest that objective monitoring of tremor features with an accelerometer can be utilized to extract subtle characteristics that distinguish PD from ET (Barrantes et al., 2017; Brennan et al., 2002; Burne et al., 2002; Deuschl et al., 2000; Henderson et al., 1994; Hossen et al., 2013; LeMoyne et al., 2010, 2015; Woods et al., 2014; Zeuner et al., 2003; Zimmermann et al”
From Combined accelerometer and genetic analysis to differentiate essential tremor from Parkinson’s disease (2018) · cites this paper as Barrantes et al., 2017
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Previous research has shown the effectiveness of power spectral analysis of acceleration signal is effective in the detection of tremor24,39–41.”
From Wearable sensors during drawing tasks to measure the severity of essential tremor (2022) · cites this paper as [39]
The cited source says what the claim attributes to it.
In the citing paper
“Already, some studies have shown that wearable sensors and smartphones can be utilized to distinguish individuals with ET from healthy individuals and people with PD (85–91).”
From Could Wearable and Mobile Technology Improve the Management of Essential Tremor? (2018) · cites this paper as [90]
In the citing paper
“While the results of these prior studies are highly encouraging, achieving between 85% and 95% accuracy, testing either required maneuvers administered by support staff, and/or was performed in a selected population with a confirmed pathological hand tremor.”
From Combined accelerometer and genetic analysis to differentiate essential tremor from Parkinson’s disease (2018) · cites this paper as Barrantes et al., 2017
In the citing paper
“Preliminary studies suggest that monitoring of tremor characteristics with consumer grade accelerometer devices could be a more accessible approach to the discrimination of PD from ET, but these studies have been performed in well-controlled clinical settings requiring multiple maneuvers and oversight from clinical or research staff, and thus may not be representative of at-home monitoring in the”
From Combined accelerometer and genetic analysis to differentiate essential tremor from Parkinson’s disease (2018) · cites this paper as Barrantes et al., 2017
3 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Hughes, A. J., Daniel, S. E., Kilford, L., & Lees, A. J. (1992) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.55.3.181 · Cited by 10,378
Halliday, D. M., Rosenberg, J. R., Amjad, A. M., Breeze, P., Conway, B. A., & Farmer, S. F. (1995) · Progress in Biophysics and Molecular Biology · doi:10.1016/s0079-6107(96)00009-0 · Cited by 1,107
The diagnosis of Parkinson’s disease
Tolosa, E., Wenning, G., & Poewe, W. (2006) · The Lancet Neurology · doi:10.1016/s1474-4422(05)70285-4 · Cited by 902
Self-citationThe pathophysiology of essential tremor and parkinson's tremor
Helmich, R. C., Toni, I., Deuschl, G., & Bloem, B. R. (2013) · Current Neurology and Neuroscience Reports · doi:10.1007/s11910-013-0378-8 · Cited by 294
(2000) · PubMed · Cited by 193
Determinants of physiologic tremor in a large normal population
Raethjen, J., Pawlas, F., Lindemann, M., Wenzelburger, R., & Deuschl, G. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00384-9 · Cited by 184
Smart watch accelerometry for analysis and diagnosis of tremor
Wile, D. J., Ranawaya, R., & Kiss, Z. H. T. (2014) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.04.021 · Cited by 148
A Smartphone-Based Tool for Assessing Parkinsonian Hand Tremor
Kostikis, N., Hristu-Varsakelis, D., Arnaoutoglou, M., & Kotsavasiloglou, C. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2471093 · Cited by 139
Using a smart phone as a standalone platform for detection and monitoring of pathological tremors
Daneault, J.-F., Carignan, B., Codère, C. É., Sadikot, A. F., & Duval, C. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2012.00357 · Cited by 85
Distinguishing the Central Drive to Tremor in Parkinson’s Disease and Essential Tremor
Brittain, J.-S., Cagnan, H., Mehta, A. R., Saifee, T. A., Edwards, M. J., & Brown, P. (2015) · The Journal of Neuroscience · doi:10.1523/jneurosci.3768-14.2015 · Cited by 77
Cited by
Teleneurology and mobile technologies: the future of neurological care
Dorsey, E. R., Glidden, A. M., Holloway, M. R., Birbeck, G. L., & Schwamm, L. H. (2018) · Nature Reviews Neurology · doi:10.1038/nrneurol.2018.31 · Cited by 258
Essential tremor: diagnosis and management
Shanker, V. (2019) · BMJ · doi:10.1136/bmj.l4485 · Cited by 182
Shakeran, Z., Keyhanfar, M., Varshosaz, J., & Sutherland, D. S. (2020) · Materials Science and Engineering C · doi:10.1016/j.msec.2020.111526 · Cited by 148
Smartphone motor testing to distinguish idiopathic REM sleep behavior disorder, controls, and PD
Arora, S., Baig, F., Lo, C., Barber, T. R., Lawton, M., Zhan, A., Rolinski, M., Ruffmann, C., Klein, J. C., Rumbold, J., et al. (2018) · Neurology · doi:10.1212/wnl.0000000000006366 · Cited by 155
Health system responsiveness: a systematic evidence mapping review of the global literature
Khan, G., Kagwanja, N., Whyle, E. B., Gilson, L., Molyneux, S. C., Schaay, N., Tsofa, B., Barasa, E., & Olivier, J. (2021) · International Journal for Equity in Health · doi:10.1186/s12939-021-01447-w · Cited by 108
Metadata
- Authors
- Barrantes, S., Sánchez Egea, A. J., González Rojas, H. A., Martí, M. J., Compta, Y., Valldeoriola, F., Simo Mezquita, E., Tolosa, E., & Valls-Solè, J.
- Affiliations
- Universitat de Barcelona (ES)
- Biomedical Research Networking Center on Neurodegenerative Diseases (ES)
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2017-08-25
- Volume
- 12
- Issue
- 8
- Pages
- e0183843
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC5571972
- OpenAlex
- W2747786350
- Cited by
- 106
- References
- 23
- Citations by year
- 2026: 4 · 2025: 6 · 2024: 9 · 2023: 17 · 2022: 15 · 2021: 20 · 2020: 10 · 2019: 11 · 2018: 12 · 2017: 2
- FWCI
- 6.66
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- RECERCAT (Consorci de Serveis Universitaris de Catalunya) (acceptedVersion, other-oa)
- UPCommons institutional repository (Universitat Politècnica de Catalunya) (submittedVersion, cc-by-nc-nd)
- Dipòsit Digital de la Universitat de Barcelona (Universitat de Barcelona) (submittedVersion, cc-by)
- LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Universitat de Barcelona
- Universitat Politècnica de Catalunya
- Topics
- Health Sciences › Medicine › Clinical Neurology › Parkinson's Disease Mechanisms and Treatments
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Keywords
- Parkinson's disease, essential tremor, differential diagnosis, smartphone accelerometer, tremor, time-frequency analysis, spectral power, wearable sensing, diagnosis
- MeSH terms
- Smartphone, Diagnosis, Differential, Humans, Parkinson Disease, Prospective Studies, Case-Control Studies, Essential Tremor, Accelerometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Differential diagnosis between Parkinson's disease and essential tremor using the smartphone's accelerometer. https://app.cochat.ai/papers/10.1371/journal.pone.0183843
- The paper
- Barrantes, S., Sánchez Egea, A. J., González Rojas, H. A., Martí, M. J., Compta, Y., Valldeoriola, F., Simo Mezquita, E., Tolosa, E., & Valls-Solè, J. (2017). Differential diagnosis between Parkinson's disease and essential tremor using the smartphone's accelerometer. PLoS ONE. https://doi.org/10.1371/journal.pone.0183843
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.