A neuromechanics-based powered ankle exoskeleton to assist walking post-stroke: a feasibility study
Open accessThe DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Abstract
BACKGROUND: In persons post-stroke, diminished ankle joint function can contribute to inadequate gait propulsion. To target paretic ankle impairments, we developed a neuromechanics-based powered ankle exoskeleton. Specifically, this exoskeleton supplies plantarflexion assistance that is proportional to the user's paretic soleus electromyography (EMG) amplitude only during a phase of gait when the stance limb is subjected to an anteriorly directed ground reaction force (GRF). The purpose of this feasibility study was to examine the short-term effects of the powered ankle exoskeleton on the mechanics and energetics of gait. METHODS: Five subjects with stroke walked with a powered ankle exoskeleton on the paretic limb for three 5 minute sessions. We analyzed the peak paretic ankle plantarflexion moment, paretic ankle positive work, symmetry of GRF propulsion impulse, and net metabolic power. RESULTS: The exoskeleton increased the paretic plantarflexion moment by 16% during the powered walking trials relative to unassisted walking condition (p < .05). Despite this enhanced paretic ankle moment, there was no significant increase in paretic ankle positive work, or changes in any other mechanical variables with the powered assistance. The exoskeleton assistance appeared to reduce the net metabolic power gradually with each 5 minute repetition, though no statistical significance was found. In three of the subjects, the paretic soleus activation during the propulsion phase of stance was reduced during the powered assistance compared to unassisted walking (35% reduction in the integrated EMG amplitude during the third powered session). CONCLUSIONS: This feasibility study demonstrated that the exoskeleton can enhance paretic ankle moment. Future studies with greater sample size and prolonged sessions are warranted to evaluate the effects of the powered ankle exoskeleton on overall gait outcomes in persons post-stroke.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Classification of Walking Handicap in the Stroke Population
Perry, J., Garrett, M., Gronley, J. K., & Mulroy, S. J. (1995) · Stroke · doi:10.1161/01.str.26.6.982 · Cited by 1,560
Review of control strategies for robotic movement training after neurologic injury
Marchal-Crespo, L., & Reinkensmeyer, D. J. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-20 · Cited by 1,182
Neptune, R. R., Kautz, S. A., & Zajac, F. E. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00105-1 · Cited by 1,132 · cited 3×
“The ankle joint, in healthy individuals, generate more mechanical energy than any other muscle groups [11] and play a critical role in forward propulsion and swing phase initiation [12].”
BackgroundThe energy expenditure of normal and pathologic gait
Waters, R. L., & Mulroy, S. (1999) · Gait & Posture · doi:10.1016/s0966-6362(99)00009-0 · Cited by 1,111 · cited 1×
“These individuals, compared to healthy adults, typically walk with slower self-selected speeds [1], greater inter-limb asymmetry [2,3] and elevated metabolic cost [4,5].”
BackgroundRobot assisted gait training with Active Leg Exoskeleton (ALEX)
Banala, S. K., Kim, S. H., Agrawal, S. K., & Scholz, J. P. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008280 · Cited by 751 · cited 1×
“, knee, hip) [22-27].”
Chen, G., Patten, C., Kothari, D. H., & Zajac, F. E. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.06.009 · Cited by 701 · cited 1×
“Furthermore, impaired ankle mechanics may lead to a series of compensations elsewhere, including greater reliance on the non-paretic limb [8,14].”
BackgroundMulticenter Randomized Clinical Trial Evaluating the Effectiveness of the Lokomat in Subacute Stroke
Hidler, J., Nichols, D., Pelliccio, M., Brady, K., Campbell, D. D., Kahn, J. H., & Hornby, T. G. (2009) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968308326632 · Cited by 652 · cited 1×
“, knee, hip) [22-27].”
Body-Weight–Supported Treadmill Rehabilitation after Stroke
Duncan, P. W., Sullivan, K. J., Behrman, A. L., Azen, S. P., Wu, S. S., Nadeau, S. E., Dobkin, B. H., Rose, D. K., Tilson, J. K., Cen, S., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1010790 · Cited by 652 · cited 1×
“Contemporary post-stroke rehabilitation approaches may include body weight support training to offload a portion of the body’s weight [15,16], split-belt treadmill training [17,18] and sensory feedback presented in a virtual environment [19-21] to improve symmetry and/ or increase walking speeds.”
BackgroundGait Asymmetry in Community-Ambulating Stroke Survivors
Patterson, K. K., Parafianowicz, I., Danells, C. J., Closson, V., Verrier, M. C., Staines, W. R., Black, S. E., & McIlroy, W. E. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.08.142 · Cited by 643 · cited 1×
“These individuals, compared to healthy adults, typically walk with slower self-selected speeds [1], greater inter-limb asymmetry [2,3] and elevated metabolic cost [4,5].”
BackgroundDerivation of formulae used to calculate energy expenditure in man.
Brockway, J. M. (1987) · PubMed · Cited by 585
Cited by
A soft robotic exosuit improves walking in patients after stroke
Awad, L. N., Bae, J., O’Donnell, K., De Rossi, S. M. M., Hendron, K., Sloot, L. H., Kudzia, P., Allen, S., Holt, K. G., Ellis, T. D., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aai9084 · Cited by 672
“This allowed us to determine whether the exosuit’s effects on poststroke walking depend on the timing of ankle PF assistance (50).”
BackgroundOpportunities and challenges in the development of exoskeletons for locomotor assistance
Siviy, C., Baker, L. M., Quinlivan, B. T., Porciuncula, F., Swaminathan, K., Awad, L. N., & Walsh, C. J. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00984-1 · Cited by 258
Performance Evaluation of Lower Limb Exoskeletons: A Systematic Review
Pinto-Fernandez, D., Torricelli, D., Sanchez-Villamanan, M. D. C., Aller, F., Mombaur, K., Conti, R., Vitiello, N., Moreno, J. C., & Pons, J. L. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.2989481 · Cited by 220
Koller, J. R., Jacobs, D. A., Ferris, D. P., & Remy, C. D. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0086-5 · Cited by 162
“It is important to note that the control scheme presented here is not the first variation on the traditional proportional myoelectric control algorithm [36]; however, to the best of our knowledge it is the first to implement an adaptive gain.”
Metadata
- Authors
- Takahashi, K. Z., Lewek, M. D., & Sawicki, G. S.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2015
- Volume
- 12
- Issue
- 1
- Pages
- 23
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2121039301
- Cited by
- 166
- References
- 62
- FWCI
- 5.82
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.