Gait speed using powered robotic exoskeletons after spinal cord injury: a systematic review and correlational study
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Powered robotic exoskeletons are an emerging technology of wearable orthoses that can be used as an assistive device to enable non-ambulatory individuals with spinal cord injury (SCI) to walk, or as a rehabilitation tool to improve walking ability in ambulatory individuals with SCI. No studies to date have systematically reviewed the literature on the efficacy of powered exoskeletons on restoring walking function. Our objective was to systematically review the literature to determine the gait speed attained by individuals with SCI when using a powered exoskeleton to walk, factors influencing this speed, and characteristics of studies involving a powered exoskeleton (e.g. inclusion criteria, screening, and training processes). A systematic search in computerized databases was conducted to identify articles that reported on walking outcomes when using a powered exoskeleton. Individual gait speed data from each study was extracted. Pearson correlations were performed between gait speed and 1) age, 2) years post-injury, 3) injury level, and 4) number of training sessions. Fifteen articles met inclusion criteria, 14 of which investigated the powered exoskeleton as an assistive device for non-ambulatory individuals and one which used it as a training intervention for ambulatory individuals with SCI. The mean gait speed attained by non-ambulatory participants (n = 84) while wearing a powered exoskeleton was 0.26 m/s, with the majority having a thoracic-level motor-complete injury. Twelve articles reported individual data for the non-ambulatory participants, from which a positive correlation was found between gait speed and 1) age (r = 0.27, 95 % CI 0.02-0.48, p = 0.03, 63 participants), 2) injury level (r = 0.27, 95 % CI 0.02-0.48, p = 0.03, 63 participants), and 3) training sessions (r = 0.41, 95 % CI 0.16-0.61, p = 0.002, 55 participants). In conclusion, powered exoskeletons can provide non-ambulatory individuals with thoracic-level motor-complete SCI the ability to walk at modest speeds. This speed is related to level of injury as well as training time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Esquenazi, A., Talaty, M., Packel, A., & Saulino, M. (2012) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e318269d9a3 · Cited by 958 · cited 7×
“Four articles [16, 21, 23, 24] addressed and reported no change in spasticity, and five [16, 21, 23, 24, 27] which addressed”
BackgroundInfluentialZeilig, G., Weingarden, H., Zwecker, M., Dudkiewicz, I., Bloch, A., & Esquenazi, A. (2012) · The Journal of Spinal Cord Medicine · doi:10.1179/2045772312y.0000000003 · Cited by 537
Shmuelof, L., Krakauer, J. W., & Mazzoni, P. (2012) · Journal of Neurophysiology · doi:10.1152/jn.00856.2011 · Cited by 415 · cited 1×
“Repetitive task practice is a requirement for improved speed and accuracy of a new skill [34], and is a possible explanation for this relationship.”
BackgroundWho wants to walk? Preferences for recovery after SCI: a longitudinal and cross-sectional study
Ditunno, P. L., Patrick, M., Stineman, M., & Ditunno, J. F. (2008) · Spinal Cord · doi:10.1038/sj.sc.3102172 · Cited by 332
A Review of Lower Extremity Assistive Robotic Exoskeletons in Rehabilitation Therapy
Chen, G., Chan, C. K., Guo, Z., & Yu, H. (2013) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.2014010453 · Cited by 270 · cited 2×
“for ambulatory individuals with SCI [9].”
BackgroundNontraumatic spinal cord injury: Incidence, epidemiology, and functional outcome
McKinley, W. O., Seel, R. T., & Hardman, J. T. (1999) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(99)90162-4 · Cited by 257 · cited 1×
“Younger individuals with SCI tend to sustain a traumatic SCI, while older individuals with SCI tend to have a non-traumatic SCI [30, 31].”
BackgroundAach, M., Cruciger, O., Sczesny-Kaiser, M., Höffken, O., Meindl, R. C., Tegenthoff, M., Schwenkreis, P., Sankai, Y., & Schildhauer, T. A. (2014) · The Spine Journal · doi:10.1016/j.spinee.2014.03.042 · Cited by 218 · cited 8×
“[13] study, these two participants underwent only 20 training sessions over 10 weeks, which did not include continuous treadmill training.”
BackgroundMethodInfluentialFarris, R. J., Quintero, H. A., Murray, S. A., Ha, K. H., Hartigan, C., & Goldfarb, M. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2268320 · Cited by 208 · cited 2×
“(2014) [18] Indego Assistive device 1 (AIS A, T10) 6MWT, 10MWT, TUG 20 sessions in one year”
BackgroundDesign and evaluation of Mina: A robotic orthosis for paraplegics
Neuhaus, P. D., Noorden, J. H., Craig, T. J., Torres, T., Kirschbaum, J., & Pratt, J. E. (2011) · 2011 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975468 · Cited by 208 · cited 10×
“Four articles [16, 21, 23, 24] addressed and reported no change in spasticity, and five [16, 21, 23, 24, 27] which addressed”
BackgroundMethodInfluential
Cited by
A soft robotic exosuit improves walking in patients after stroke
Awad, L. N., Bae, J., O’Donnell, K., De Rossi, S. M. M., Hendron, K., Sloot, L. H., Kudzia, P., Allen, S., Holt, K. G., Ellis, T. D., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aai9084 · Cited by 672
“enable nonambulatory individuals to walk again (41); however, for ambulatory individuals, the lightweight and nonrestrictive nature of this technology has the potential to facilitate a more natural interaction with the wearer and minimize disruption of the natural dynamics of walking (42).”
BackgroundDonati, A. R. C., Shokur, S., Morya, E., Campos, D. S. F., Moioli, R. C., Gitti, C. M., Augusto, P. B., Tripodi, S., Pires, C. G., Pereira, G. A., et al. (2016) · Scientific Reports · doi:10.1038/srep30383 · Cited by 428
“Such clinical evaluation started on the first day patients began training (Day 0), and were repeated after 4, 7, 10, and 12 months.”
Powered robotic exoskeletons in post-stroke rehabilitation of gait: a scoping review
Louie, D. R., & Eng, J. J. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0162-5 · Cited by 350
Self-citationMiller, L., Zimmermann, A., & Herbert, W. (2016) · Medical Devices: Evidence and Research · doi:10.2147/mder.s103102 · Cited by 313
Nam, K. Y., Kim, H. J., Kwon, B. S., Park, J.-W., Lee, H. J., & Yoo, A. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0232-3 · Cited by 302
Exoskeleton and End‐Effector Robots for Upper and Lower Limbs Rehabilitation: Narrative Review
Molteni, F., Gasperini, G., Cannaviello, G., & Guanziroli, E. (2018) · PM&R · doi:10.1016/j.pmrj.2018.06.005 · Cited by 274
Powered exoskeletons for bipedal locomotion after spinal cord injury
Contreras-Vidal, J. L., A Bhagat, N., Brantley, J., Cruz-Garza, J. G., He, Y., Manley, Q., Nakagome, S., Nathan, K., Tan, S. H., Zhu, F., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/031001 · Cited by 216
Robotic Rehabilitation and Spinal Cord Injury: a Narrative Review
Mekki, M., Delgado, A. D., Fry, A., Putrino, D., & Huang, V. (2018) · Neurotherapeutics · doi:10.1007/s13311-018-0642-3 · Cited by 216
Robotic exoskeletons: The current pros and cons
Gorgey, A. S. (2018) · World Journal of Orthopedics · doi:10.5312/wjo.v9.i9.112 · Cited by 205
Esquenazi, A., Talaty, M., & Jayaraman, A. (2017) · PM&R · doi:10.1016/j.pmrj.2016.07.534 · Cited by 175
“level of injury, and number of training sessions [22].”
BackgroundAcute spinal cord injury: Pathophysiology and pharmacological intervention (Review)
Zhang, Y., Al Mamun, A., Yuan, Y., Lu, Q., Xiong, J., Yang, S., Wu, C., Wu, Y., & Wang, J. (2021) · Molecular Medicine Reports · doi:10.3892/mmr.2021.12056 · Cited by 167
“EXO‑supported walking can considerably reduce spasticity and enhance bowel movement (225).”
Metadata
- Authors
- Spinal Cord Injury Research Evidence (SCIRE) Research Team, Louie, D. R., Eng, J. J., & Lam, T.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2015-10-14
- Volume
- 12
- Issue
- 1
- Pages
- 82-82
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2106701171
- Cited by
- 224
- References
- 33
- FWCI
- 2.04
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.