The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Safety and tolerance of the ReWalk ™ exoskeleton suit for ambulation by people with complete spinal cord injury: A pilot study
Open accessAbstract
OBJECTIVES: The objective of the study was to evaluate the safety and tolerance of use of the ReWalk™ exoskeleton ambulation system in people with spinal cord injury. Measures of functional ambulation were also assessed and correlated to neurological spinal cord level, age, and duration since injury. STUDY DESIGN: Case series observational study. SETTING: A national spinal cord injury centre. METHODS: Six volunteer participants were recruited from the follow-up outpatient clinic. Safety was assessed with regard to falls, status of the skin, status of the spine and joints, blood pressure, pulse, and electrocardiography (ECG). Pain and fatigue were graded by the participants using a visual analogue scale pre- and post-training. Participants completed a 10-statement questionnaire regarding safety, comfort, and secondary medical effects. After being able to walk 100 m, timed up and go, distance walked in 6 minutes and 10-m timed walk were measured. RESULTS: There were no adverse safety events. Use of the system was generally well tolerated, with no increase in pain and a moderate level of fatigue after use. Individuals with lower level of spinal cord injury performed walking more efficiently. CONCLUSION: Volunteer participants were able to ambulate with the ReWalk™ for a distance of 100 m, with no adverse effects during the course of an average of 13-14 training sessions. The participants were generally positive regarding the use of the system.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The ReWalk exoskeleton developed by ReWalk Robotics (Marlborough, MA, USA; Figure 2A) is a LEEs that provides powered hip and knee motion to enable individuals with SCI to stand upright and walk [32], [33].”
From Recent developments and challenges of lower extremity exoskeletons (2016) · cites this paper as [32]
Citations
Cites
Reliability of the Visual Analog Scale for Measurement of Acute Pain
Bijur, P. E., Silver, W., & Gallagher, E. J. (2001) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2001.tb01132.x · Cited by 2,067
International Standards for Neurological and Functional Classification of Spinal Cord Injury
Maynard, F. M., Bracken, M. B., Creasey, G., Jr, J. F. D., Donovan, W. H., Ducker, T. B., Garber, S. L., Marino, R. J., Stover, S. L., Tator, C. H., et al. (1997) · Spinal Cord · doi:10.1038/sj.sc.3100432 · Cited by 2,048
Treadmill training of paraplegic patients using a robotic orthosis.
Colombo, G., Joerg, M., Schreier, R., & Dietz, V. (2000) · PubMed · Cited by 1,114
Robot assisted gait training with Active Leg Exoskeleton (ALEX)
Banala, S. K., Kim, S. H., Agrawal, S. K., & Scholz, J. P. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008280 · Cited by 751
van Hedel, H. J., Wirz, M., & Dietz, V. (2005) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2004.02.010 · Cited by 485
A mechanized gait trainer for restoration of gait.
Hesse, S., & Uhlenbrock, D. (2000) · PubMed · Cited by 388
Three exercise paradigms differentially improve sensory recovery after spinal cord contusion in rats
Hutchinson, K. J. (2004) · Brain · doi:10.1093/brain/awh160 · Cited by 341
Waring, W. P., Biering-Sorensen, F., Burns, S., Donovan, W., Graves, D., Jha, A., Jones, L., Kirshblum, S., Marino, R., Mulcahey, M. J., et al. (2010) · The Journal of Spinal Cord Medicine · doi:10.1080/10790268.2010.11689712 · Cited by 226
Winchester, P., McColl, R., Querry, R., Foreman, N., Mosby, J., Tansey, K., & Williamson, J. (2005) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968305281515 · Cited by 221
Brain motor system function after chronic, complete spinal cord injury
Cramer, S. C., Lastra, L., Lacourse, M. G., & Cohen, M. J. (2005) · Brain · doi:10.1093/brain/awh648 · Cited by 218
Research works printed but not linked: 2
- Colombo G, 2000, J Rehabil Res Dev, 37, 693
- Hesse S, 2000, J Rehabil Res Dev, 37, 701
Cited by
Ahuja, C. S., Wilson, J. R., Nori, S., Kotter, M. R. N., Druschel, C., Curt, A., & Fehlings, M. G. (2017) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2017.18 · Cited by 2,441
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“…P/O devices in ADL, developers must establish trust with regulatory bodies, funding agencies, insurance companies, clinicians and end users that such devices are not only effective at their intended application, but are safe to use within reasonably expectable circumstances (see e.g. [241,242]).”
State of the Art and Future Directions for Lower Limb Robotic Exoskeletons
Young, A. J., & Ferris, D. P. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2521160 · Cited by 901
“The ReWalk bilaterally actuates the knee and hip joints to enable walking, standing, and sit-to-stand maneuvers for patients with SCI [44].”
BackgroundInfluentialA Review on Lower Limb Rehabilitation Exoskeleton Robots
Shi, D., Zhang, W., Zhang, W., & Ding, X. (2019) · Chinese Journal of Mechanical Engineering · doi:10.1186/s10033-019-0389-8 · Cited by 508
Recent developments and challenges of lower extremity exoskeletons
Chen, B., Ma, H., Qin, L.-Y., Gao, F., Chan, K.-M., Law, S.-W., Qin, L., & Liao, W.-H. (2016) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2015.09.007 · Cited by 501
“The ReWalk exoskeleton developed by ReWalk Robotics (Marlborough, MA, USA; Figure 2A) is a LEEs that provides powered hip and knee motion to enable individuals with SCI to stand upright and walk [32,33].”
Method
Metadata
- Authors
- Zeilig, G., Weingarden, H., Zwecker, M., Dudkiewicz, I., Bloch, A., & Esquenazi, A.
- Affiliations
- Tel Aviv University (IL)
- Sheba Medical Center (IL)
- Moss Rehabilitation Hospital (US)
- Corresponding author
- Zwecker, Manuel
- Venue
- The Journal of Spinal Cord Medicine
- Publisher
- Informa UK Limited
- Published
- 2012-03
- Volume
- 35
- Issue
- 2
- Pages
- 96-101
- ISSN
- 1079-0268 (ISSN-L)
- 2045-7723
- PMC
- PMC3304563
- OpenAlex
- W2026523445
- Cited by
- 537
- References
- 18
- Citations by year
- 2026: 20 · 2025: 42 · 2024: 56 · 2023: 33 · 2022: 62 · 2021: 46 · 2020: 49 · 2019: 53 · 2018: 48 · 2017: 47 · 2016: 30 · 2015: 31 · 2014: 10 · 2013: 8 · 2012: 1
- FWCI
- 9.11
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Locations
- Journal of Spinal Cord Medicine (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Health Sciences › Medicine › Clinical Neurology › Spinal Cord Injury Research
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- spinal cord injury, complete spinal cord injury, gait assistance, functional ambulation, safety, tolerability, pain and fatigue, level of spinal cord injury, walking distance, Timed Up and Go test
- MeSH terms
- Adolescent, Adult, Aged, Exercise Therapy, Female, Follow-Up Studies, Gait, Humans, Male, Middle Aged, Pilot Projects, Surveys and Questionnaires, Spinal Cord Injuries, Walking, Outcome Assessment, Health Care, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Safety and tolerance of the ReWalk ™ exoskeleton suit for ambulation by people with complete spinal cord injury: A pilot study. https://app.cochat.ai/papers/10.1179/2045772312y.0000000003
- The paper
- Zeilig, G., Weingarden, H., Zwecker, M., Dudkiewicz, I., Bloch, A., & Esquenazi, A. (2012). Safety and tolerance of the ReWalk ™ exoskeleton suit for ambulation by people with complete spinal cord injury: A pilot study. The Journal of Spinal Cord Medicine. https://doi.org/10.1179/2045772312y.0000000003