Cited by 226Balance, Gait, and Falls PreventionParkinson's Disease Mechanisms and TreatmentsContext-Aware Activity Recognition Systems

A systematic review of the characteristics and validity of monitoring technologies to assess Parkinson’s disease

Open access
Godinho, Catarina, Domingos, Josefa, Cunha, Guilherme, Santos, Ana T., Fernandes, Ricardo M., Abreu, Daisy, Gonçalves, Nilza, Matthews, Helen +11 more·2016·Journal of NeuroEngineering and Rehabilitation

Abstract

BACKGROUND: There is growing interest in having objective assessment of health-related outcomes using technology-based devices that provide unbiased measurements which can be used in clinical practice and scientific research. Many studies have investigated the clinical manifestations of Parkinson's disease using such devices. However, clinimetric properties and clinical validation vary among the different devices. METHODS: Given such heterogeneity, we sought to perform a systematic review in order to (i) list, (ii) compare and (iii) classify technological-based devices used to measure motor function in individuals with Parkinson's disease into three groups, namely wearable, non-wearable and hybrid devices. A systematic literature search of the PubMed database resulted in the inclusion of 168 studies. These studies were grouped based on the type of device used. For each device we reviewed availability, use, reliability, validity, and sensitivity to change. The devices were then classified as (i) 'recommended', (ii) 'suggested' or (iii) 'listed' based on the following criteria: (1) used in the assessment of Parkinson's disease (yes/no), (2) used in published studies by people other than the developers (yes/no), and (3) successful clinimetric testing (yes/no). RESULTS: Seventy-three devices were identified, 22 were wearable, 38 were non-wearable, and 13 were hybrid devices. In accordance with our classification method, 9 devices were 'recommended', 34 devices were 'suggested', and 30 devices were classified as 'listed'. Within the wearable devices group, the Mobility Lab sensors from Ambulatory Parkinson's Disease Monitoring (APDM), Physilog®, StepWatch 3, TriTrac RT3 Triaxial accelerometer, McRoberts DynaPort, and Axivity (AX3) were classified as 'recommended'. Within the non-wearable devices group, the Nintendo Wii Balance Board and GAITRite® gait analysis system were classified as 'recommended'. Within the hybrid devices group only the Kinesia® system was classified as 'recommended'.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s12984-016-0136-7

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 31 · Cited by 226

Authors
Godinho, C., Domingos, J., Cunha, G., Santos, A. T., Fernandes, R. M., Abreu, D., Gonçalves, N., Matthews, H., Isaacs, T., Duffen, J., Al-Jawad, A., Larsen, F., Serrano, A., Weber, P., Thoms, A., Sollinger, S., Graessner, H., Maetzler, W., & Ferreira, J. J.
Affiliations
  • University of Lisbon (PT)
  • Cure Parkinson's Trust (GB)
  • Hahn-Schickard-Gesellschaft für angewandte Forschung (DE)
  • Hasomed (Germany) (DE)
  • AbilityNet (United Kingdom) (GB)
  • University of Tübingen (DE)
  • Hertie Institute for Clinical Brain Research (DE)
Corresponding author
Ferreira, Joaquim J.
Venue
Journal of NeuroEngineering and Rehabilitation
Published
2016-03-12
Volume
13
Issue
1
Pages
24-24
ISSN
1743-0003 (ISSN-L)
OpenAlex
W2294748375
Cited by
226
References
31
Citations by year
2026: 8 · 2025: 17 · 2024: 19 · 2023: 21 · 2022: 13 · 2021: 31 · 2020: 28 · 2019: 34 · 2018: 27 · 2017: 22 · 2016: 6
FWCI
5.14
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • Journal of NeuroEngineering and Rehabilitation (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Multimedialen Archiv und Publikationsserver der Christian-Albrechts-Universität zu Kiel (Christian-Albrechts-Universität zu Kiel) (publishedVersion, cc-by)
  • Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) (submittedVersion, cc-by)
Funders
Seventh Framework Programme, Cooperation – ICT (288557)
Topics
  • Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
  • Health Sciences › Medicine › Neurology › Parkinson's Disease Mechanisms and Treatments
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
Keywords
Parkinson's disease, wearable sensors, hybrid devices, motor function assessment, clinimetric properties, device validation, reliability statistics, sensitivity to change, gait analysis, accelerometer, Wii Balance Board, GAITRite
MeSH terms
Humans, Parkinson Disease, Reproducibility of Results, Monitoring, Ambulatory, Accelerometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review