The ReWalk ReStore™ soft robotic exosuit: a multi-site clinical trial of the safety, reliability, and feasibility of exosuit-augmented post-stroke gait rehabilitation
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Background: Atypical walking in the months and years after stroke constrain community reintegration and reduce mobility, health, and quality of life. The ReWalk ReStore™ is a soft robotic exosuit designed to assist the propulsion and ground clearance subtasks of post-stroke walking by actively assisting paretic ankle plantarflexion and dorsiflexion. Previous proof-of-concept evaluations of the technology demonstrated improved gait mechanics and energetics and faster and farther walking in users with post-stroke hemiparesis. We sought to determine the safety, reliability, and feasibility of using the ReStore™ during post-stroke rehabilitation. Methods: A multi-site clinical trial (NCT03499210) was conducted in preparation for an application to the United States Food and Drug Administration (FDA). The study included 44 users with post-stroke hemiparesis who completed up to 5 days of training with the ReStore™ on the treadmill and over ground. In addition to primary and secondary endpoints of safety and device reliability across all training activities, an exploratory evaluation of the effect of multiple exposures to using the device on users’ maximum walking speeds with and without the device was conducted prior to and following the five training visits. Results: All 44 study participants completed safety and reliability evaluations. Thirty-six study participants completed all five training days. No device-related falls or serious adverse events were reported. A low rate of device malfunctions was reported by clinician-operators. Regardless of their reliance on ancillary assistive devices, after only 5 days of walking practice with the device, study participants increased both their device-assisted (Δ: 0.10 ± 0.03 m/s) and unassisted (Δ: 0.07 ± 0.03 m/s) maximum walking speeds (P’s < 0.05). Conclusions: When used under the direction of a licensed physical therapist, the ReStore™ soft exosuit is safe and reliable for use during post-stroke gait rehabilitation to provide targeted assistance of both paretic ankle plantarflexion and dorsiflexion during treadmill and overground walking. Trial registration: NCT03499210. Prospectively registered on March 28, 2018.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Meaningful change and responsiveness in common physical performance measures in older adults.
Perera, S., Mody, S. H., Woodman, R. C., & Studenski, S. A. (2006) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2006.00701.x · Cited by 2,513
The biomechanics and motor control of human gait : normal, elderly and pathological
Winter, D. A. (1991) · University of Waterloo Press eBooks · Cited by 1,428
Esquenazi, A., Talaty, M., Packel, A., & Saulino, M. (2012) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e318269d9a3 · Cited by 958 · cited 1×
“Unlike rigid exoskeletons that are powerful enough to move the limbs without user input [23, 24], exosuitgenerated forces must work in synchrony with the user’s movements to improve their walking.”
Self-citationClark, D. J., Ting, L. H., Zajac, F. E., Neptune, R. R., & Kautz, S. A. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00825.2009 · Cited by 875
Energetic Consequences of Walking Like an Inverted Pendulum: Step-to-Step Transitions
Kuo, A. D., Donelan, J. M., & Ruina, A. (2005) · Exercise and Sport Sciences Reviews · doi:10.1097/00003677-200504000-00006 · Cited by 675
A soft robotic exosuit improves walking in patients after stroke
Awad, L. N., Bae, J., O’Donnell, K., De Rossi, S. M. M., Hendron, K., Sloot, L. H., Kudzia, P., Allen, S., Holt, K. G., Ellis, T. D., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aai9084 · Cited by 672
Self-citationTilson, J. K., Sullivan, K. J., Cen, S. Y., Rose, D. K., Koradia, C. H., Azen, S. P., Duncan, P. W., & for the Locomotor Experience Applied Post Stroke (LEAPS) Investigative Team (2010) · Physical Therapy · doi:10.2522/ptj.20090079 · Cited by 494
Dynamic Principles of Gait and Their Clinical Implications
Kuo, A. D., & Donelan, J. M. (2010) · Physical Therapy · doi:10.2522/ptj.20090125 · Cited by 485
Calabrò, R. S., Naro, A., Russo, M., Bramanti, P., Carioti, L., Balletta, T., Buda, A., Manuli, A., Filoni, S., & Bramanti, A. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0377-8 · Cited by 185
Roelker, S. A., Bowden, M. G., Kautz, S. A., & Neptune, R. R. (2019) · Gait & Posture · doi:10.1016/j.gaitpost.2018.10.027 · Cited by 167
Peterson, C. L., Kinney, A. L., Kautz, S. A., & Neptune, R. R. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.04.027 · Cited by 148
Bae, J., Siviy, C., Rouleau, M., Menard, N., Odonnell, K., Geliana, I., Athanassiu, M., Ryan, D., Bibeau, C., Sloot, L., et al. (2018) · 2018 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2018.8461046 · Cited by 145
Self-citationThe influence of merged muscle excitation modules on post-stroke hemiparetic walking performance
Allen, J. L., Kautz, S. A., & Neptune, R. R. (2013) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2013.06.003 · Cited by 123
Farris, D. J., Hampton, A., Lewek, M. D., & Sawicki, G. S. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0012-x · Cited by 119
Stanhope, V. A., Knarr, B. A., Reisman, D. S., & Higginson, J. S. (2014) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2014.03.013 · Cited by 115
Influence of Speed on Walking Economy Poststroke
Reisman, D. S., Rudolph, K. S., & Farquhar, W. B. (2009) · Neurorehabilitation and neural repair · doi:10.1177/1545968308328732 · Cited by 112
Awad, L. N., Kudzia, P., Revi, D. A., Ellis, T. D., & Walsh, C. J. (2020) · IEEE Open Journal of Engineering in Medicine and Biology · doi:10.1109/ojemb.2020.2984429 · Cited by 111
Self-citationA soft exosuit for patients with stroke: Feasibility study with a mobile off-board actuation unit
Bae, J., Maria De Rossi, S. M., O'Donnell, K., Hendron, K. L., Awad, L. N., Teles Dos Santos, T. R., De Araujo, V. L., Ding, Y., Holt, K. G., Ellis, T. D., et al. (2015) · 2015 IEEE International Conference on Rehabilitation Robotics (ICORR) · doi:10.1109/icorr.2015.7281188 · Cited by 99
Self-citationSiviy, C., Bae, J., Baker, L. M., Porciuncula, F., Baker, T. C., Ellis, T. D., Awad, L. N., & Walsh, C. J. (2020) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2020.2965072 · Cited by 90
Self-citationAwad, L. N., Reisman, D. S., Pohlig, R. T., & Binder‐Macleod, S. A. (2015) · Neurorehabilitation and neural repair · doi:10.1177/1545968315619696 · Cited by 81
Self-citationAwad, L. N., Bae, J., Kudzia, P., Long, A., Hendron, K. L., Holt, K. G., O’Donnell, K., Ellis, T. D., & Walsh, C. J. (2017) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0000000000000800 · Cited by 81
Self-citationBarthuly, A. M., Bohannon, R. W., & Gorack, W. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.01.002 · Cited by 78
Biomechanical mechanisms underlying exosuit-induced improvements in walking economy after stroke
Bae, J., Awad, L. N., Long, A., O’Donnell, K., Hendron, K., Holt, K. G., Ellis, T. D., & Walsh, C. J. (2018) · Journal of Experimental Biology · doi:10.1242/jeb.168815 · Cited by 62
Self-citationBrough, L. G., Kautz, S. A., Bowden, M. G., Gregory, C. M., & Neptune, R. R. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.11.011 · Cited by 38
Cited by
Opportunities and challenges in the development of exoskeletons for locomotor assistance
Siviy, C., Baker, L. M., Quinlivan, B. T., Porciuncula, F., Swaminathan, K., Awad, L. N., & Walsh, C. J. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00984-1 · Cited by 258
Self-citationSoft Robotic Suits: State of the Art, Core Technologies, and Open Challenges
Xiloyannis, M., Alicea, R., Georgarakis, A.-M., Haufe, F. L., Wolf, P., Masia, L., & Riener, R. (2022) · IEEE Transactions on Robotics · doi:10.1109/tro.2021.3084466 · Cited by 225
“A more recent multi-site clinical trial proved that a similar commercialized device is a safe and feasible means of supporting post-stroke gait rehabilitation [41].”
BackgroundArtificial intelligence meets medical robotics
Yip, M., Salcudean, S., Goldberg, K., Althoefer, K., Menciassi, A., Opfermann, J. D., Krieger, A., Swaminathan, K., Walsh, C. J., Huang, H. (., et al. (2023) · Science · doi:10.1126/science.adj3312 · Cited by 207
Metadata
- Authors
- Awad, L. N., Esquenazi, A., Francisco, G. E., Nolan, K. J., & Jayaraman, A.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2020-06-18
- Volume
- 17
- Issue
- 1
- Pages
- 80-80
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W3035926617
- Cited by
- 161
- References
- 24
- FWCI
- 6.34
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.