Hepatic toxicology following single and multiple exposure of engineered nanomaterials utilising a novel primary human 3D liver microtissue model
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The liver has a crucial role in metabolic homeostasis as well as being the principal detoxification centre of the body, removing xenobiotics and waste products which could potentially include some nanomaterials (NM). With the ever increasing public and occupational exposure associated with accumulative production of nanomaterials, there is an urgent need to consider the possibility of detrimental health consequences of engineered NM exposure. It has been shown that exposure via inhalation, intratracheal instillation or ingestion can result in NM translocation to the liver. Traditional in vitro or ex vivo hepatic nanotoxicology models are often limiting and/or troublesome (i.e. reduced metabolism enzymes, lacking important cell populations, unstable with very high variability, etc.). METHODS: In order to rectify these issues and for the very first time we have utilised a 3D human liver microtissue model to investigate the toxicological effects associated with a single or multiple exposure of a panel of engineered NMs (Ag, ZnO, MWCNT and a positively charged TiO₂). RESULTS: Here we demonstrate that the repeated exposure of the NMs is more damaging to the liver tissue as in comparison to a single exposure with the adverse effects more significant following treatment with the Ag and ZnO as compared with the TiO₂ and MWCNT NMs (in terms of cytotoxicity, cytokine secretion, lipid peroxidation and genotoxicity). CONCLUSIONS: Overall, this study demonstrates that the human microtissue model utilised herein is an excellent candidate for replacement of traditional in vitro single cell hepatic models and further progression of liver nanotoxicology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Godoy, P., Hewitt, N. J., Albrecht, U., Andersen, M. E., Ansari, N., Bhattacharya, S., Bode, J. G., Bolleyn, J., Borner, C., Böttger, J., et al. (2013) · Archives of Toxicology · doi:10.1007/s00204-013-1078-5 · Cited by 1,280 · cited 3×
“It is widely argued that in vitro hepatocyte systems (including cell lines and systems without optimal artificial extracellular matrices) might not be ideal for functional and metabolic studies as the cells lose key liver specific functions especially their cytochrome P450 (CYP450) activity [18,20,21].”
BackgroundSelf-citationImmune tolerance: What is unique about the liver
Tiegs, G., & Lohse, A. W. (2010) · Journal of Autoimmunity · doi:10.1016/j.jaut.2009.08.008 · Cited by 394
Multi-cell type human liver microtissues for hepatotoxicity testing
Messner, S., Agarkova, I., Moritz, W., & Kelm, J. M. (2013) · Archives of Toxicology · doi:10.1007/s00204-012-0968-2 · Cited by 319
Self-citationLiguori, M. J., Blomme, E. A. G., & Waring, J. F. (2008) · Drug Metabolism and Disposition · doi:10.1124/dmd.107.017608 · Cited by 84 · cited 1×
“cant variations between different human donors [52,53].”
Cited by
Organ-on-a-chip devices advance to market
Zhang, B., & Radisic, M. (2017) · Lab on a Chip · doi:10.1039/c6lc01554a · Cited by 437
Human and environmental impacts of nanoparticles: a scoping review of the current literature
Kumah, E. A., Fopa, R. D., Harati, S., Boadu, P., Zohoori, F. V., & Pak, T. (2023) · BMC Public Health · doi:10.1186/s12889-023-15958-4 · Cited by 411
Lauschke, V. M., Hendriks, D. F. G., Bell, C. C., Andersson, T. B., & Ingelman-Sundberg, M. (2016) · Chemical Research in Toxicology · doi:10.1021/acs.chemrestox.6b00150 · Cited by 241
3D Cultivation Techniques for Primary Human Hepatocytes
Bachmann, A., Moll, M., Gottwald, E., Nies, C., Zantl, R., Wagner, H., Burkhardt, B., Sánchez, J., Ladurner, R., Thasler, W., et al. (2015) · Microarrays · doi:10.3390/microarrays4010064 · Cited by 59
“The generated micro-livers exerted hepatic functions, such as bile canaliculi formation and glycogen storage, while in long-term culture for up to 14 days, the micro-tissues showed an increased sensitivity towards repeated doses of diclofenac [36] and nanomaterials [60].”
BackgroundIn Vitro Three‐Dimensional Liver Models for Nanomaterial DNA Damage Assessment
Llewellyn, S. V., Niemeijer, M., Nymark, P., Moné, M. J., van de Water, B., Conway, G. E., Jenkins, G. J. S., & Doak, S. H. (2021) · Small · doi:10.1002/smll.202006055 · Cited by 41
Metadata
- Authors
- Kermanizadeh, A., L hr, M., Roursgaard, M., Messner, S., Gunness, P., Kelm, J. M., Møller, P., Stone, V., & Loft, S.
- Venue
- Particle and Fibre Toxicology
- Published
- 2014-10-20
- Volume
- 11
- Issue
- 1
- Pages
- 56-56
- ISSN
- 1743-8977 (ISSN-L)
- OpenAlex
- W2102244990
- Cited by
- 82
- References
- 4
- FWCI
- 3.87
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hepatic toxicology following single and multiple exposure of engineered nanomaterials utilising a novel primary human 3D liver microtissue model. https://app.cochat.ai/papers/10.1186/s12989-014-0056-2
- The paper
- Kermanizadeh, A., L hr, M., Roursgaard, M., Messner, S., Gunness, P., Kelm, J. M., Møller, P., Stone, V., & Loft, S. (2014). Hepatic toxicology following single and multiple exposure of engineered nanomaterials utilising a novel primary human 3D liver microtissue model. Particle and Fibre Toxicology. https://doi.org/10.1186/s12989-014-0056-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.