CoChat

Is mean heart dose a relevant surrogate parameter of left ventricle and coronary arteries exposure during breast cancer radiotherapy: a dosimetric evaluation based on individually-determined radiation dose (BACCARAT study)

Open access
Jacob, Sophie, Camilleri, Jérémy, Derreumaux, Sylvie, Walker, Valentin, Lairez, Olivier, Lapeyre, Mathieu, Bruguière, Eric, Pathak, Atul, Bernier, Marie-Odile, Laurier, Dominique, Ferrieres, Jean, Gallocher, Olivier, Latorzeff, Igor, Pinel, Baptiste, Franck, Denis, Chevelle, Christian, Jimenez, Gaëlle, Broggio, David · 2019 · Radiation Oncology
Cited by 175

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Intra-individual heterogeneity of cardiac exposure is an issue in breast cancer (BC) radiotherapy that was poorly considered in previous cardiotoxicity studies mainly based on mean heart dose (MHD). This dosimetric study analyzes the distribution of individually-determined radiation doses to the heart and its substructures including coronary arteries and evaluate whether MHD is a relevant surrogate parameter of dose for these substructures. Data were collected from the BACCARAT prospective study that included left or right unilateral BC patients treated with 3D-Conformal Radiotherapy (RT) between 2015 and 2017 and followed-up for 2 years with repeated cardiac imaging examinations. A coronary computed tomography angiography (CCTA) was performed before RT for all patients. Registration of the planning CT and CCTA images allowed delineation of the coronary arteries on the planning CT images. Using the 3D dose matrix generated during treatment planning and the added coronary contours, dose distributions were generated for whole heart and the following substructures: left ventricle (LV), left main coronary artery (LMCA), left anterior descending artery (LAD), left circumflex artery (LCX) and right coronary artery (RCA). A descriptive analysis of the physical doses in Gray (Gy) was performed, Dmean was the volume-weighted mean dose. Dose distributions were generated for 89 left-sided BC patients (MHD = 2.9 ± 1.5 Gy, Dmean_LAD = 15.7 ± 3.1 Gy) and 15 right-sided BC patients (MHD = 0.5 ± 0.1 Gy; Dmean_RCA = 1.2 ± 0.4 Gy). For left-sided BC patients, the ratio Dmean_LAD/MHD was around 5. Pearson correlation coefficients between MHD and Dmean for delineated substructures were all statistically significant. However, for all substructures, the coefficient of determination R2 indicated that the proportion of the variance in Dmean of the substructure predictable from MHD was moderate to low (in particular R2 = 0.45 for LAD). Among left-sided BC patients with MHD < 3Gy, 56% of patients could nevertheless receive LAD doses above 40Gy (V40 > 0). Our study illustrates that MHD is not enough to predict with confidence individual patient dose to the LV and coronary arteries, in particular the LAD. For precise radiotherapy-induced cardiotoxicity studies it would be necessary to consider the distribution of doses within these cardiac substructures rather than just the MHD. ClinicalTrials.gov: NCT02605512 , Registered 6 November 2015 - Retrospectively registered.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s13014-019-1234-z

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Risk of Ischemic Heart Disease in Women after Radiotherapy for Breast Cancer

    Darby, S. C., Ewertz, M., McGale, P., Bennet, A. M., Blom-Goldman, U., Brønnum, D., Correa, C., Cutter, D., Gagliardi, G., Gigante, B., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1209825 · Cited by 3,974 · cited 4×

    “In Darby’s study [5], estimated mean doses to the LAD and MHD were also Table 3 Association parameters between mean dose to the left ventricle and coronary arteries and the mean heart dose”
    BackgroundInfluential
  • A cardiac contouring atlas for radiotherapy

    Duane, F., Aznar, M. C., Bartlett, F., Cutter, D. J., Darby, S. C., Jagsi, R., Lorenzen, E. L., McArdle, O., McGale, P., Myerson, S., et al. (2017) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2017.01.008 · Cited by 308 · cited 1×

    “Dreaming of a ‘Swiss Army Knife’ for cardiac doses, some studies developed methodology based on atlas and auto-segmentation that could help to standardize contouring for these structures [12, 13, 25, 26].”
    Background

Show all 2 references

Cited by

See all 175

Metadata

Authors
Jacob, S., Camilleri, J., Derreumaux, S., Walker, V., Lairez, O., Lapeyre, M., Bruguière, E., Pathak, A., Bernier, M.-O., Laurier, D., Ferrieres, J., Gallocher, O., Latorzeff, I., Pinel, B., Franck, D., Chevelle, C., Jimenez, G., & Broggio, D.
Venue
Radiation Oncology
Published
2019-02-07
Volume
14
Issue
1
Pages
29-29
ISSN
1748-717X (ISSN-L)
OpenAlex
W2919716094
Cited by
175
References
2
FWCI
16.47
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Is mean heart dose a relevant surrogate parameter of left ventricle and coronary arteries exposure during breast cancer radiotherapy: a dosimetric evaluation based on individually-determined radiation dose (BACCARAT study). https://app.cochat.ai/papers/10.1186/s13014-019-1234-z
The paper
Jacob, S., Camilleri, J., Derreumaux, S., Walker, V., Lairez, O., Lapeyre, M., Bruguière, E., Pathak, A., Bernier, M.-O., Laurier, D., Ferrieres, J., Gallocher, O., Latorzeff, I., Pinel, B., Franck, D., Chevelle, C., Jimenez, G., & Broggio, D. (2019). Is mean heart dose a relevant surrogate parameter of left ventricle and coronary arteries exposure during breast cancer radiotherapy: a dosimetric evaluation based on individually-determined radiation dose (BACCARAT study). Radiation Oncology. https://doi.org/10.1186/s13014-019-1234-z

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.