CoChat

Second degree AV block and severely impaired contractility in cardiac myxedema: a case report

Open access
Chatzitomaris, Apostolos, Scheeler, Michael, Gotzmann, Michael, Köditz, Roland, Schildroth, Janice, Knyhala, Kathy Miriam, Nicolas, Volkmar, Heyer, Christoph, Mügge, Andreas, Klein, Harald H, Dietrich, Johannes W · 2015 · Thyroid Research
Cited by 11

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

The heart is a major target organ for thyroid hormone action. Severe overt hypothyroidism can result in diastolic hypertension, lowered cardiac output, impaired left ventricular contractility and diastolic relaxation, pericardial effusion and bradycardia. However, the function of the atrial pacemaker is usually normal and the degree by which the heart rate slows down is often modest. Here we report the case of a 20 year old male Caucasian with severe overt hypothyroidism. He presented with syncopation due to second degree atrioventricular block type Mobitz 2 and heart failure with reduced ejection fraction (38 %). Laboratory testing revealed a severe overt hypothyroidism with markedly elevated TSH (>100 mIU/L) and reduced fT3 and fT4 levels. The condition was caused by hypothyroid Graves' disease (Graves' disease with Hashimoto component). Although magnetic resonance imaging of the heart demonstrated decreased cardiac contractility and pericardial effusion, suggesting peri-myocarditis, plasma levels for BNP and troponin I were low. A possible infectious cause was unlikely, since testing for cardiotropic viruses was negative. The patient was treated with intravenous levothyroxine and after peripheral euthyroidism had been achieved, left ventricular ejection fraction returned to normal and pericardial effusion dissolved. Additionally, bradycardiac episodes abated, although intermittent second degree AV block was still occasionally present during the night. In conclusion, overt hypothyroidism may be associated by cardiac myxedema affecting both electrophysiology and contractility, observations that underscore the necessity of thyroid testing in different phenotypes of heart failure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s13044-015-0018-2

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 11

Metadata

Authors
Chatzitomaris, A., Scheeler, M., Gotzmann, M., Köditz, R., Schildroth, J., Knyhala, K. M., Nicolas, V., Heyer, C., Mügge, A., Klein, H. H., & Dietrich, J. W.
Venue
Thyroid Research
Published
2015-05-19
Volume
8
Issue
1
Pages
6-6
ISSN
1756-6614 (ISSN-L)
OpenAlex
W2119520659
Cited by
11
References
4
FWCI
1.01
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Second degree AV block and severely impaired contractility in cardiac myxedema: a case report. https://app.cochat.ai/papers/10.1186/s13044-015-0018-2
The paper
Chatzitomaris, A., Scheeler, M., Gotzmann, M., Köditz, R., Schildroth, J., Knyhala, K. M., Nicolas, V., Heyer, C., Mügge, A., Klein, H. H., & Dietrich, J. W. (2015). Second degree AV block and severely impaired contractility in cardiac myxedema: a case report. Thyroid Research. https://doi.org/10.1186/s13044-015-0018-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.