Simplified lung ultrasound protocol shows excellent prediction of extravascular lung water in ventilated intensive care patients
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Introduction: Ultrasound of the lung and quantification of B lines was recently introduced as a novel tool to detect overhydration. In the present study, we aimed to evaluate a four-region protocol of lung ultrasound to determine the pulmonary fluid status in ventilated patients in the intensive care unit. Methods: Fifty patients underwent both lung ultrasound and transpulmonary thermodilution measurement with the PiCCO system. An ultrasound score based on number of single and confluent B lines per intercostal space was used to quantify pulmonary overhydration. To check for reproducibility, two different intensivists who were blinded as to the ultrasound pictures reassessed and classified them using the same scoring system. The results were compared with those obtained using other methods of evaluating hydration status, including extravascular lung water index (EVLWI) and intrathoracic blood volume index calculated with data from transpulmonary thermodilution measurements. Moreover, chest radiographs were assessed regarding signs of pulmonary overhydration and categorized based on a numeric rating scale. Results: Lung water assessment by ultrasound using a simplified protocol showed excellent correlation with EVLWI over a broad range of lung hydration grades and ventilator settings. Correlation of chest radiography and EVLWI was less accurate. No correlation whatsoever was found with central venous pressure measurement. Conclusion: Lung ultrasound is a useful, non-invasive tool in predicting hydration status in mechanically ventilated patients. The four-region protocol that we used is time-saving, correlates well with transpulmonary thermodilution measurements and performs markedly better than chest radiography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619 · cited 5×
“(C) Bland-Altman plot comparing the difference (EVLWI − US score) with the average (of EVLWI and US score).”
MethodInfluentialMeasuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
International evidence-based recommendations for point-of-care lung ultrasound
International Liaison Committee on Lung Ultrasound (ILC-LUS) for the International Consensus Conference on Lung Ultrasound (ICC-LUS), Volpicelli, G., Elbarbary, M., Blaivas, M., Lichtenstein, D. A., Mathis, G., Kirkpatrick, A. W., Melniker, L., Gargani, L., Noble, V. E., et al. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2513-4 · Cited by 2,874 · cited 4×
“Various protocols have been used to assess extravascular lung water (EVLW) in patients in the intensive care unit (ICU) and in outpatients, but to date no agreement has been reached about the best protocol to use in the ICU setting [5].”
BackgroundMethodInfluentialThe Effectiveness of Right Heart Catheterization in the Initial Care of Critically III Patients
Connors, A. F. (1996) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1996.03540110043030 · Cited by 2,210 · cited 1×
“Measurement of CVP or the use of pulmonary artery catheters is still common, although their utility and value in guiding fluid therapy have been questioned in recent years [18,19].”
BackgroundGandevia, B., & Tovell, A. (1964) · PubMed · Cited by 2,069
Marik, P. E., Baram, M., & Vahid, B. (2008) · Chest · doi:10.1378/chest.07-2331 · Cited by 1,516 · cited 1×
“Measurement of CVP or the use of pulmonary artery catheters is still common, although their utility and value in guiding fluid therapy have been questioned in recent years [18,19].”
BackgroundLichtenstein, D., Goldstein, I., Mourgeon, E., Cluzel, P., Grenier, P., & Rouby, J.-J. (2004) · Anesthesiology · doi:10.1097/00000542-200401000-00006 · Cited by 1,077 · cited 1×
“Researchers in previous studies also reported conflicting results regarding the performance of chest radiographs in predicting pulmonary hyperhydration, interstitial syndrome or high cardiac filling pressures [28-30].”
ResultThe Comet-tail Artifact: An Ultrasound Sign of Alveolar-Interstitial Syndrome
LICHTENSTEIN, D., MÉZIÈRE, G., BIDERMAN, P., GEPNER, A., & BARRÉ, O. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.156.5.96-07096 · Cited by 1,075 · cited 1×
“Using lung ultrasound to detect so-called B lines proved to be a useful diagnostic tool in diagnosing pulmonary edema in the emergency medicine setting and in animal studies, where the detection and quantification of so-called B lines showed correlation with clinical assessment, radiologic findings, natriuretic peptid…”
Prognostic Value of Extravascular Lung Water in Critically Ill Patients
Sakka, S. G., Klein, M., Reinhart, K., & Meier‐Hellmann, A. (2002) · CHEST Journal · doi:10.1378/chest.122.6.2080 · Cited by 672 · cited 6×
“The cutoff values of 7 and 15 ml/kg used in our study were chosen on the basis of different reported mortality rates in critically ill patients associated with these values, but they remain arbitrary [12].”
BackgroundMethodInfluential“Ultrasound Comet-Tail Images”: A Marker Of Pulmonary Edema
Agricola, E., Bove, T., Oppizzi, M., Marino, G., Zangrillo, A., Margonato, A., & Picano, E. (2005) · Chest · doi:10.1378/chest.127.5.1690 · Cited by 597
Cited by
Acute respiratory distress syndrome
Sweeney, R. M., & McAuley, D. F. (2016) · The Lancet · doi:10.1016/s0140-6736(16)00578-x · Cited by 398
Metadata
- Authors
- Enghard, P., Rademacher, S., Nee, J., Hasper, D., Engert, U., Jörres, A., & Kruse, J. M.
- Venue
- Critical Care
- Published
- 2015-02-06
- Volume
- 19
- Issue
- 1
- Pages
- 36-36
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W2022941944
- Cited by
- 202
- References
- 27
- FWCI
- 14.09
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.