CoChat

The accuracy of transcranial Doppler in excluding intracranial hypertension following acute brain injury: a multicenter prospective pilot study

Open access
Rasulo, Frank A., Bertuetti, Rita, Robba, Chiara, Lusenti, Francesco, Cantoni, Alfredo, Bernini, Marta, Girardini, Alan, Calza, Stefano, Piva, Simone, Fagoni, Nazzareno, Latronico, Nicola · 2017 · Critical Care
Cited by 161

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Untimely diagnosis of intracranial hypertension may lead to delays in therapy and worsening of outcome. Transcranial Doppler (TCD) detects variations in cerebral blood flow velocity which may correlate with intracranial pressure (ICP). We investigated if intracranial hypertension can be accurately excluded through use of TCD. METHOD: This was a multicenter prospective pilot study in patients with acute brain injury requiring invasive ICP (ICPi) monitoring. ICP estimated with TCD (ICPtcd) was compared with ICPi in three separate time frames: immediately before ICPi placement, immediately after ICPi placement, and 3 hours following ICPi positioning. Sensitivity and specificity, and concordance correlation coefficient between ICPi and ICPtcd were calculated. Receiver operating curve (ROC) and the area under the curve (AUC) analyses were estimated after measurement averaging over time. RESULTS: A total of 38 patients were enrolled, and of these 12 (31.6%) had at least one episode of intracranial hypertension. One hundred fourteen paired measurements of ICPi and ICPtcd were gathered for analysis. With dichotomized ICPi (≤20 mmHg vs >20 mmHg), the sensitivity of ICPtcd was 100%; all measurements with high ICPi (>20 mmHg) also had a high ICPtcd values. Bland-Altman plot showed an overestimation of 6.2 mmHg (95% CI 5.08-7.30 mmHg) for ICPtcd compared to ICPi. AUC was 96.0% (95% CI 89.8-100%) and the estimated best threshold was at ICPi of 24.8 mmHg corresponding to a sensitivity 100% and a specificity of 91.2%. CONCLUSIONS: This study provides preliminary evidence that ICPtcd may accurately exclude intracranial hypertension in patients with acute brain injury. Future studies with adequate power are needed to confirm this result.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s13054-017-1632-2

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 161

Metadata

Authors
Rasulo, F. A., Bertuetti, R., Robba, C., Lusenti, F., Cantoni, A., Bernini, M., Girardini, A., Calza, S., Piva, S., Fagoni, N., & Latronico, N.
Venue
Critical Care
Published
2017-02-27
Volume
21
Issue
1
Pages
44-44
ISSN
1364-8535 (ISSN-L)
OpenAlex
W2594041123
Cited by
161
References
2
FWCI
8.95
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.