Rapid evaporative ionisation mass spectrometry of electrosurgical vapours for the identification of breast pathology: towards an intelligent knife for breast cancer surgery
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Re-operation for positive resection margins following breast-conserving surgery occurs frequently (average = 20-25%), is cost-inefficient, and leads to physical and psychological morbidity. Current margin assessment techniques are slow and labour intensive. Rapid evaporative ionisation mass spectrometry (REIMS) rapidly identifies dissected tissues by determination of tissue structural lipid profiles through on-line chemical analysis of electrosurgical aerosol toward real-time margin assessment. METHODS: Electrosurgical aerosol produced from ex-vivo and in-vivo breast samples was aspirated into a mass spectrometer (MS) using a monopolar hand-piece. Tissue identification results obtained by multivariate statistical analysis of MS data were validated by histopathology. Ex-vivo classification models were constructed from a mass spectral database of normal and tumour breast samples. Univariate and tandem MS analysis of significant peaks was conducted to identify biochemical differences between normal and cancerous tissues. An ex-vivo classification model was used in combination with bespoke recognition software, as an intelligent knife (iKnife), to predict the diagnosis for an ex-vivo validation set. Intraoperative REIMS data were acquired during breast surgery and time-synchronized to operative videos. RESULTS: A classification model using histologically validated spectral data acquired from 932 sampling points in normal tissue and 226 in tumour tissue provided 93.4% sensitivity and 94.9% specificity. Tandem MS identified 63 phospholipids and 6 triglyceride species responsible for 24 spectral differences between tissue types. iKnife recognition accuracy with 260 newly acquired fresh and frozen breast tissue specimens (normal n = 161, tumour n = 99) provided sensitivity of 90.9% and specificity of 98.8%. The ex-vivo and intra-operative method produced visually comparable high intensity spectra. iKnife interpretation of intra-operative electrosurgical vapours, including data acquisition and analysis was possible within a mean of 1.80 seconds (SD ±0.40). CONCLUSIONS: The REIMS method has been optimised for real-time iKnife analysis of heterogeneous breast tissues based on subtle changes in lipid metabolism, and the results suggest spectral analysis is both accurate and rapid. Proof-of-concept data demonstrate the iKnife method is capable of online intraoperative data collection and analysis. Further validation studies are required to determine the accuracy of intra-operative REIMS for oncological margin assessment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cancer treatment and survivorship statistics, 2016
Miller, K. D., Siegel, R. L., Lin, C. C., Mariotto, A. B., Kramer, J. L., Rowland, J. H., Stein, K. D., Alteri, R., & Jemal, A. (2016) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21349 · Cited by 6,066
Cancer treatment and survivorship statistics, 2014
DeSantis, C. E., Lin, C. C., Mariotto, A. B., Siegel, R. L., Stein, K. D., Kramer, J. L., Alteri, R., Robbins, A. S., & Jemal, A. (2014) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21235 · Cited by 2,779
Stewart, B. W., & Kleihues, P. (2003) · Cited by 2,386
METLIN—a metabolite mass spectral database
Smith, C. A., Maille, G. O., Want, E. J., Qin, C., Trauger, S. A., Brandon, T. R., Custodio, D. E., Abagyan, R., & Siuzdak, G. (2005) · Therapeutic Drug Monitoring · doi:10.1097/01.ftd.0000179845.53213.39 · Cited by 2,226 · cited 1×
“Tentative ion identification was performed by searching peak m/z values in the METLIN metabolite database and with LIPID MAPS® online tools [45, 46], which was refined using the MS/MS data.”
MethodLIPID MAPS online tools for lipid research
Fahy, E., Sud, M., Cotter, D., & Subramaniam, S. (2007) · Nucleic Acids Research · doi:10.1093/nar/gkm324 · Cited by 911
Moran, M. S., Schnitt, S. J., Giuliano, A. E., Harris, J. R., Khan, S. A., Horton, J., Klimberg, S., Chavez-MacGregor, M., Freedman, G., Houssami, N., et al. (2014) · Annals of Surgical Oncology · doi:10.1245/s10434-014-3481-4 · Cited by 612
Intraoperative Tissue Identification Using Rapid Evaporative Ionization Mass Spectrometry
Balog, J., Sasi-Szabó, L., Kinross, J., Lewis, M. R., Muirhead, L. J., Veselkov, K., Mirnezami, R., Dezső, B., Damjanovich, L., Darzi, A., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3005623 · Cited by 608 · cited 2×
“Aerosol produced as a result of electrosurgical activation was aspirated via the electrosurgical hand-piece [41] and transferred through a plastic tube to the mass spectrometer using a Venturi air jet pump.”
BackgroundMethodSelf-citationHoussami, N., Macaskill, P., Luke Marinovich, M., & Morrow, M. (2014) · Annals of Surgical Oncology · doi:10.1245/s10434-014-3480-5 · Cited by 532 · cited 2×
“44 in the odds ratio of local recurrence for positive margins (tumour on ink) but with no significant benefits demonstrated for wider margins [8].”
BackgroundHilvo, M., Denkert, C., Lehtinen, L., Müller, B., Brockmöller, S., Seppänen-Laakso, T., Budczies, J., Bucher, E., Yetukuri, L., Castillo, S., et al. (2011) · Cancer Research · doi:10.1158/0008-5472.can-10-3894 · Cited by 532 · cited 2×
“Interestingly, PC (16:0/ 16:0), PC (18:0/20:4), PC (18:1/20:4) have been previously identified to be associated with ER-negative tumours and higher grade tumours, and associated with decreased overall survival in breast cancer patients [50].”
BackgroundVariability in Reexcision Following Breast Conservation Surgery
McCahill, L. E., Single, R. M., Aiello Bowles, E. J., Feigelson, H. S., James, T. A., Barney, T., Engel, J. M., & Onitilo, A. A. (2012) · JAMA · doi:10.1001/jama.2012.43 · Cited by 516
Cited by
Analytical Challenges and Recent Advances in Mass Spectrometry Based Lipidomics
Rustam, Y. H., & Reid, G. E. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04836 · Cited by 282
Mass spectrometry-based proteomics as an emerging tool in clinical laboratories
Birhanu, A. G. (2023) · Clinical Proteomics · doi:10.1186/s12014-023-09424-x · Cited by 220
“More than 40 ambient ionization techniques, including Rapid evaporative ionization MS (REIMS), have now been described in the literature since the last decades [117, 133, 137].”
MethodInfluentialPorta Siegel, T., Hamm, G., Bunch, J., Cappell, J., Fletcher, J. S., & Schwamborn, K. (2018) · Molecular Imaging and Biology · doi:10.1007/s11307-018-1267-y · Cited by 187
“In this case, one of the advantages of monitoring a specific agent is the possibility to identify tumour margins without building an extensive tissue-specific database beforehand [76].”
BackgroundMetabolomics technology and bioinformatics for precision medicine
Azad, R. K., & Shulaev, V. (2019) · Briefings in Bioinformatics · doi:10.1093/bib/bbx170 · Cited by 180
“It uses the aerosol by-product of electrosurgical (Bovie) tools [194].”
Method
Metadata
- Authors
- St John, E. R., Balog, J., McKenzie, J. S., Rossi, M., Covington, A., Muirhead, L., Bodai, Z., Rosini, F., Speller, A. V. M., Shousha, S., Ramakrishnan, R., Darzi, A., Takats, Z., & Leff, D. R.
- Venue
- Breast Cancer Research
- Published
- 2017-05-23
- Volume
- 19
- Issue
- 1
- Pages
- 59-59
- ISSN
- 1465-5411 (ISSN-L)
- 1465-542X
- OpenAlex
- W2617752143
- Cited by
- 217
- References
- 48
- FWCI
- 11.39
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.