Mixed methods feasibility study for a trial of blood pressure telemonitoring for people who have had stroke/transient ischaemic attack (TIA)
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Good blood pressure (BP) control reduces the risk of recurrence of stroke/transient ischaemic attack (TIA). Although there is strong evidence that BP telemonitoring helps achieve good control, none of the major trials have considered the effectiveness in stroke/TIA survivors. We therefore conducted a feasibility study for a trial of BP telemonitoring for stroke/TIA survivors with uncontrolled BP in primary care. METHOD: Phase 1 was a pilot trial involving 55 patients stratified by stroke/TIA randomised 3:1 to BP telemonitoring for 6 months or usual care. Phase 2 was a qualitative evaluation and comprised semi-structured interviews with 16 trial participants who received telemonitoring and 3 focus groups with 23 members of stroke support groups and 7 carers. RESULTS: Overall, 125 patients (60 stroke patients, 65 TIA patients) were approached and 55 (44%) patients were randomised including 27 stroke patients and 28 TIA patients. Fifty-two participants (95%) attended the 6-month follow-up appointment, but one declined the second daytime ambulatory blood pressure monitoring (ABPM) measurement resulting in a 93% completion rate for ABPM - the proposed primary outcome measure for a full trial. Adherence to telemonitoring was good; of the 40 participants who were telemonitoring, 38 continued to provide readings throughout the 6 months. There was a mean reduction of 10.1 mmHg in systolic ABPM in the telemonitoring group compared with 3.8 mmHg in the control group, which suggested the potential for a substantial effect from telemonitoring. Our qualitative analysis found that many stroke patients were concerned about their BP and telemonitoring increased their engagement, was easy, convenient and reassuring. CONCLUSIONS: A full-scale trial is feasible, likely to recruit well and have good rates of compliance and follow-up. TRIAL REGISTRATION: ISRCTN61528726 15/12/2011.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Banks, J. L., & Marotta, C. A. (2007) · Stroke · doi:10.1161/01.str.0000258355.23810.c6 · Cited by 2,253 · cited 2×
“The mean reduction of 10.1 (SD 15.6) mmHg in systolic ABPM in the Table 1 Patient characteristics at baseline Intervention N = 40 Control N = 15 Male/female (number) (Total group) 27/13 6/9 Stroke group 14/6 2/5 TIA group 13/7 4/4 Age – mean in years (SD) (Total group) 69.9 (12.6) 73.5 (11.7) Stroke 67.8 (14.5) 69.1 (…”
MethodInfluentialHospital Anxiety and Depression Scale
Zigmond, A. S., & Snaith, R. P. (2013) · PsycTESTS Dataset · doi:10.1037/t03589-000 · Cited by 946
Steventon, A., Bardsley, M., Billings, J., Dixon, J., Doll, H., Hirani, S., Cartwright, M., Rixon, L., Knapp, M., Henderson, C., et al. (2012) · BMJ · doi:10.1136/bmj.e3874 · Cited by 583
Okonofua, E. C., Simpson, K. N., Jesri, A., Rehman, S. U., Durkalski, V. L., & Egan, B. M. (2006) · Hypertension · doi:10.1161/01.hyp.0000200702.76436.4b · Cited by 527
Agarwal, R., Bills, J. E., Hecht, T. J. W., & Light, R. P. (2011) · Hypertension · doi:10.1161/hypertensionaha.110.160911 · Cited by 430
Pinnock, H., Hanley, J., McCloughan, L., Todd, A., Krishan, A., Lewis, S., Stoddart, A., van der Pol, M., MacNee, W., Sheikh, A., et al. (2013) · BMJ · doi:10.1136/bmj.f6070 · Cited by 310
Self-citationThe Impact of Telehealthcare on the Quality and Safety of Care: A Systematic Overview
McLean, S., Sheikh, A., Cresswell, K., Nurmatov, U., Mukherjee, M., Hemmi, A., & Pagliari, C. (2013) · PLoS ONE · doi:10.1371/journal.pone.0071238 · Cited by 255
Self-citationBray, E. P., Holder, R., Mant, J., & McManus, R. J. (2010) · Annals of Medicine · doi:10.3109/07853890.2010.489567 · Cited by 245
Telehealthcare for long term conditions
McLean, S., Protti, D., & Sheikh, A. (2011) · BMJ · doi:10.1136/bmj.d120 · Cited by 205
Self-citation
Cited by
The Japanese Society of Hypertension Guidelines for the Management of Hypertension (JSH 2019)
Umemura, S., Arima, H., Arima, S., Asayama, K., Dohi, Y., Hirooka, Y., Horio, T., Hoshide, S., Ikeda, S., Ishimitsu, T., et al. (2019) · Hypertension Research · doi:10.1038/s41440-019-0284-9 · Cited by 1,880
Morton, K., Dennison, L., May, C., Murray, E., Little, P., McManus, R. J., & Yardley, L. (2017) · Patient Education and Counseling · doi:10.1016/j.pec.2016.10.019 · Cited by 195
Duan, Y., Xie, Z., Dong, F., Wu, Z., Lin, Z., Sun, N., & Xu, J. (2017) · Journal of Human Hypertension · doi:10.1038/jhh.2016.99 · Cited by 154
Telemonitoring at scale for hypertension in primary care: An implementation study
Hammersley, V., Parker, R., Paterson, M., Hanley, J., Pinnock, H., Padfield, P., Stoddart, A., Park, H. G., Sheikh, A., & McKinstry, B. (2020) · PLOS Medicine · doi:10.1371/journal.pmed.1003124 · Cited by 61
Self-citationQualitative study of telemonitoring of blood glucose and blood pressure in type 2 diabetes
Hanley, J., Fairbrother, P., McCloughan, L., Pagliari, C., Paterson, M., Pinnock, H., Sheikh, A., Wild, S., & McKinstry, B. (2015) · BMJ Open · doi:10.1136/bmjopen-2015-008896 · Cited by 43
Self-citation
Metadata
- Authors
- Hanley, J., Fairbrother, P., Krishan, A., McCloughan, L., Padfield, P., Paterson, M., Pinnock, H., Sheikh, A., Sudlow, C., Todd, A., & McKinstry, B.
- Venue
- Trials
- Published
- 2015-03-25
- Volume
- 16
- Issue
- 1
- Pages
- 117-117
- ISSN
- 1745-6215 (ISSN-L)
- OpenAlex
- W2120919882
- Cited by
- 34
- References
- 14
- FWCI
- 1.56
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mixed methods feasibility study for a trial of blood pressure telemonitoring for people who have had stroke/transient ischaemic attack (TIA). https://app.cochat.ai/papers/10.1186/s13063-015-0628-y
- The paper
- Hanley, J., Fairbrother, P., Krishan, A., McCloughan, L., Padfield, P., Paterson, M., Pinnock, H., Sheikh, A., Sudlow, C., Todd, A., & McKinstry, B. (2015). Mixed methods feasibility study for a trial of blood pressure telemonitoring for people who have had stroke/transient ischaemic attack (TIA). Trials. https://doi.org/10.1186/s13063-015-0628-y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.