Brazilian multicenter study for the evaluation of patients’ satisfaction of blood glucose self-monitoring with BGStar® blood glucose meter in insulinized patients with diabetes mellitus type 1 and 2
Open accessAbstract
BACKGROUND: Diabetes mellitus (DM) is considered a global epidemic, and patient self-management education and support are critical in preventing and reducing the risk of complications. Self-monitoring of blood glucose (SMBG) is essential for care of individuals with DM, helping patients to achieve and maintain target blood glucose levels. The purpose of this study is to compare the satisfaction of insulinized DM patients on SMBG with use of investigational blood glucose meter (BGM) versus their routine device. METHODS: A national, multicenter, open-label, phase 4 study was conducted on patients with type 1 or 2 DM under insulin therapy regimen, who were asked to use investigational BGM instead of their usual BGM device. The study was performed in 12 centers in Brazil for 12 weeks, with an extension period of 12 weeks. The primary endpoint was to measure the variation on the patients' level of satisfaction with investigational versus routine BGM, between visits, using a Visual Analogue Scale (VAS). Secondary endpoints addressed handling aspects, satisfaction, adherence and level of functionality and safety of investigational BGM. RESULTS: The study included 292 patients (36.6 % DM1 and 63.4 % DM2), mean age 50.9 years old (±17.3 years), 57.5 % females. There was statistically significant improvement in global satisfaction with investigational BGM compared with routine BGM according to VAS [mean VAS score raised from 78.8 mm (SD = 18.0) to 90.8 mm (SD = 12.2) between visits]. After 12 weeks, level of satisfaction with investigational BGM according to questionnaires was superior to routine BGM regardless of age group (p < 0.001), type of DM (p < 0.001) or insulin regimen (p < 0.001). Investigational BGM was also regarded as safe, with 10 patients (3.4 %) reporting a total of 13 adverse events during the study. CONCLUSIONS: Levels of satisfaction during SMBG were higher with use of investigational BGM and the device was deemed safe and easy to handle.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In a Brazilian national multicenter study, acceptance of SMBG varied depending on the device used (time for results, amount of blood needed, technology) and people's characteristics (age, glycemic control).
“a national multicenter study showed that acceptance of SMBG varied depending both on the device used (considering time for getting results, amount of blood needed, technology used) and peoples’ characteristics (age, glycemic control) [64].”
From Self-Monitoring of Blood Glucose as an Integral Part in the Management of People with Type 2 Diabetes Mellitus (2022) · cites this paper as [64]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Standards of Medical Care in Diabetes
Power, D. V. (2006) · Diabetes Care · doi:10.2337/diacare.29.02.06.dc05-1593 · Cited by 8,672 · see citing works
Global status report on noncommunicable diseases 2010.
Alwan, A. (2011) · Cited by 8,494 · see citing works
Global status report on noncommunicable diseases
Chan, M. (2010) · Cited by 1,065 · see citing works
Mendis, S., Davis, S. M., & Norrving, B. G. (2015) · Stroke · doi:10.1161/strokeaha.115.008097 · Cited by 1,023 · see citing works
Amiel, S. A., Beveridge, S., Bradley, C., Gianfrancesco, C., Heller, S. R., James, P., McKeown, N., Newton, D. F., Newton, L. D., Oliver, L., et al. (2002) · Deakin Research Online (Deakin University) · Cited by 723 · see citing works
Rodbard, H. W., Blonde, L., Ss, B., Brett, E. M., Cobin, R. H., Handelsman, Y., Hellman, R., Jellinger, P. S., Jovanovic, L. G., Levy, P., et al. (2007) · Endocrine Practice · doi:10.4158/ep.13.s1.1 · Cited by 693 · see citing works
Karter, A. J., Ackerson, L. M., Darbinian, J. A., D’Agostino, R. B., Ferrara, A., Liu, J., & Selby, J. V. (2001) · The American Journal of Medicine · doi:10.1016/s0002-9343(01)00742-2 · Cited by 595 · see citing works
Tracking global funding for the prevention and control of noncommunicable diseases.
Banerjee, A. (2012) · Bulletin of the World Health Organization · doi:10.2471/blt.12.108795 · Cited by 563 · see citing works
Global guideline for type 2 diabetes: recommendations for standard, comprehensive, and minimal care
IDF Clinical Guidelines Task Force (2006) · Diabetic Medicine · doi:10.1111/j.1464-5491.2006.01918.x · Cited by 433 · see citing works
Polonsky, W. H., Fisher, L., Schikman, C. H., Hinnen, D. A., Parkin, C. G., Jelsovsky, Z., Petersen, B., Schweitzer, M., & Wagner, R. S. (2011) · Diabetes Care · doi:10.2337/dc10-1732 · Cited by 429 · see citing works
Franciosi, M., Pellegrini, F., Berardis, G. D., Belfiglio, M., Cavaliere, D., Nardo, B. D., Greenfield, S., Kaplan, S. H., Sacco, M., Tognoni, G., et al. (2001) · Diabetes Care · doi:10.2337/diacare.24.11.1870 · Cited by 301 · see citing works
Guerci, B., Drouin, P., Grangé, V, Bougnères, P., Fontaine, P., Kerlan, V, Passa, P., Thivolet, C., Vialettes, B., & Charbonnel, B. (2003) · Diabetes & Metabolism · doi:10.1016/s1262-3636(07)70073-3 · Cited by 287 · see citing works
Evans, J. M. M., Newton, R. W., Ruta, D. A., MacDonald, T. M., Stevenson, R. J., & Morris, A. D. (1999) · BMJ · doi:10.1136/bmj.319.7202.83 · Cited by 283 · see citing works
Blood glucose self-monitoring in type 2 diabetes: a randomised controlled trial
Farmer, A. A., Wade, A. N., French, D., Simon, J., Yudkin, P. L., Gray, A., Craven, A., Goyder, L., Holman, R. R., Mant, D., et al. (2009) · Health Technology Assessment · doi:10.3310/hta13150 · Cited by 178 · see citing works
Gubitosi‐Klug, R. (2013) · Diabetes Care · doi:10.2337/dc13-2148 · Cited by 131 · see citing works
Clinical assessment of the accuracy of blood glucose measurement devices
Pfützner, A., Mitri, M., Musholt, P. B., Sachsenheimer, D., Borchert, M., Yap, A., & Forst, T. M. (2012) · Current Medical Research and Opinion · doi:10.1185/03007995.2012.673479 · Cited by 64 · see citing works
Miller, D. S., Berard, L., CHENG, A. Y. Y., et al. (2011) · Canadian Journal of Diabetes · doi:10.1016/s1499-2671(11)54003-1 · Cited by 16 · see citing works
Ramljak, S., Musholt, P. B., Schipper, C., Flacke, F., Sieber, J., Borchert, M., Forst, T. M., & Pfützner, A. (2013) · Expert Opinion on Medical Diagnostics · doi:10.1517/17530059.2013.839984 · Cited by 12 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Pleus, S., Freckmann, G., Schauer, S., Heinemann, L., Ziegler, R., Ji, L., Mohan, V., Calliari, L. E., & Hinzmann, R. (2022) · Diabetes Therapy · doi:10.1007/s13300-022-01254-8 · Cited by 55 · see citing works
- Authors
- Hissa, M. N.
- Affiliations
- Unichristus (BR)
- Corresponding author
- Hissa, Miguel Nasser
- Venue
- Diabetology & Metabolic Syndrome
- Published
- 2016-09-13
- Volume
- 8
- Issue
- 1
- Pages
- 66-66
- ISSN
- 1758-5996 (ISSN-L)
- PMC
- PMC5020543
- OpenAlex
- W2519070048
- Cited by
- 1
- References
- 19
- Citations by year
- 2022: 1
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- Diabetology & Metabolic Syndrome (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- Sanofi-Aventis
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- self-monitoring of blood glucose, blood glucose meters, patient satisfaction, insulin therapy, type 1 diabetes, type 2 diabetes, device safety, adherence, self-management education
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review