The accuracy and robustness of plasma biomarker models for amyloid PET positivity
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Background: Plasma biomarkers for Alzheimer’s disease (AD) have broad potential as screening tools in primary care and disease-modifying trials. Detecting elevated amyloid-β (Aβ) pathology to support trial recruitment or initiating Aβ-targeting treatments would be of critical value. In this study, we aimed to examine the robustness of plasma biomarkers to detect elevated Aβ pathology at different stages of the AD continuum. Beyond determining the best biomarker—or biomarker combination—for detecting this outcome, we also simulated increases in inter-assay coefficient of variability (CV) to account for external factors not considered by intra-assay variability. With this, we aimed to determine whether plasma biomarkers would maintain their accuracy if applied in a setting which anticipates higher variability (i.e., clinical routine). Methods: We included 118 participants (cognitively unimpaired [CU, n = 50], cognitively impaired [CI, n = 68]) from the ADNI study with a full plasma biomarker profile (Aβ42/40, GFAP, p-tau181, NfL) and matched amyloid imaging. Initially, we investigated how simulated CV variations impacted single-biomarker discriminative performance of amyloid status. Then, we evaluated the predictive performance of models containing different biomarker combinations, based both on original and simulated measurements. Plasma Aβ42/40 was represented by both immunoprecipitation mass spectrometry (IP-MS) and single molecule array (Simoa) methods in separate analyses. Model selection was based on a decision tree which incorporated Akaike information criterion value, likelihood ratio tests between the best-fitting models and, finally, and Schwartz’s Bayesian information criterion. Results: Increasing variation greatly impacted the performance of plasma Aβ42/40 in discriminating Aβ status. In contrast, the performance of plasma GFAP and p-tau181 remained stable with variations >20%. When biomarker models were compared, the models “AG” (Aβ42/40 + GFAP; AUC = 86.5), “A” (Aβ42/40; AUC = 82.3), and “AGP” (Aβ42/40 + GFAP + p-tau181; AUC = 93.5) were superior in determining Aβ burden in all participants, within-CU, and within-CI groups, respectively. In the robustness analyses, when repeating model selection based on simulated measurements, models including IP-MS Aβ42/40 were also most often selected. Simoa Aβ42/40 did not contribute to any selected model when used as an immunoanalytical alternative to IP-MS Aβ42/40. Conclusions: Plasma Aβ42/40, as quantified by IP-MS, shows high performance in determining Aβ positivity at all stages of the AD continuum, with GFAP and p-tau181 further contributing at CI stage. However, between-assay variations greatly impacted the performance of Aβ42/40 but not that of GFAP and p-tau181. Therefore, when dealing with between-assay CVs that exceed 5%, plasma GFAP and p-tau181 should be considered for a more robust determination of Aβ burden in CU and CI participants, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
NIA‐AA Research Framework: Toward a biological definition of Alzheimer's disease
Jack, C. R., Bennett, D. A., Blennow, K., Carrillo, M. C., Dunn, B., Haeberlein, S. B., Holtzman, D. M., Jagust, W., Jessen, F., Karlawish, J., et al. (2018) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2018.02.018 · Cited by 10,537
Self-citationThe antibody aducanumab reduces Aβ plaques in Alzheimer’s disease
Sevigny, J., Chiao, P., Bussière, T., Weinreb, P. H., Williams, L., Maier, M., Dunstan, R., Salloway, S., Chen, T., Ling, Y., et al. (2016) · Nature · doi:10.1038/nature19323 · Cited by 3,059
Alzheimer's Disease Neuroimaging Initiative (ADNI)
Petersen, R. C., Aisen, P. S., Beckett, L. A., Donohue, M. C., Gamst, A. C., Harvey, D. J., Jack, C. R., Jagust, W. J., Shaw, L. M., Toga, A. W., et al. (2010) · Neurology · doi:10.1212/wnl.0b013e3181cb3e25 · Cited by 2,572
Donanemab in Early Alzheimer’s Disease
Mintun, M. A., Lo, A. C., Duggan Evans, C., Wessels, A. M., Ardayfio, P. A., Andersen, S. W., Shcherbinin, S., Sparks, J., Sims, J. R., Brys, M., et al. (2021) · New England Journal of Medicine · doi:10.1056/nejmoa2100708 · Cited by 1,728 · cited 2×
“However, the plasma biomarker models demonstrated in this study may act, with good accuracy, as important initial screening tools to enrich a population for a larger success rate of Aβ PET scan or tau PET scans [4] in the recruitment process.”
BackgroundMethodHigh performance plasma amyloid-β biomarkers for Alzheimer's disease
Nakamura, A., Kaneko, N., Villemagne, V. L., Kato, T., Doecke, J., Doré, V., Fowler, C., Li, Q.-X., Martins, R., Rowe, C., et al. (2018) · Nature · doi:10.1038/nature25456 · Cited by 1,681
Palmqvist, S., Janelidze, S., Quiroz, Y. T., Zetterberg, H., Lopera, F., Stomrud, E., Su, Y., Chen, Y., Serrano, G. E., Leuzy, A., et al. (2020) · JAMA · doi:10.1001/jama.2020.12134 · Cited by 1,603 · cited 1×
“These additional p-tau biomarkers have both been shown to have high accuracy, together with a high fold change in AD, in determining Aβ pathology at both the preclinical and symptomatic phases of the disease and therefore may significantly contribute to the model selections, if available [10, 36].”
BackgroundSelf-citationKarikari, T. K., Pascoal, T. A., Ashton, N. J., Janelidze, S., Benedet, A. L., Rodriguez, J. L., Chamoun, M., Savard, M., Kang, M. S., Therriault, J., et al. (2020) · The Lancet Neurology · doi:10.1016/s1474-4422(20)30071-5 · Cited by 1,316
Self-citationJanelidze, S., Mattsson, N., Palmqvist, S., Smith, R., Beach, T. G., Serrano, G. E., Chai, X., Proctor, N. K., Eichenlaub, U., Zetterberg, H., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0755-1 · Cited by 1,247
Self-citationAssociation of plasma neurofilament light with neurodegeneration in patients with Alzheimer disease
Mattsson, N., Andreasson, U., Zetterberg, H., Blennow, K., & Initiative, F. T. A. D. N. (2017) · JAMA Neurology · doi:10.1001/jamaneurol.2016.6117 · Cited by 1,070
Self-citationDominantly Inherited Alzheimer Network, Preische, O., Schultz, S. A., Apel, A., Kuhle, J., Kaeser, S. A., Barro, C., Gräber, S., Kuder-Buletta, E., LaFougere, C., et al. (2019) · Nature Medicine · doi:10.1038/s41591-018-0304-3 · Cited by 927 · cited 1×
“Increases in plasma NfL are a widely reported finding in AD [20, 21] and are also observed in pre-symptomatic familial AD [22].”
Background
Cited by
Diagnostic Accuracy of a Plasma Phosphorylated Tau 217 Immunoassay for Alzheimer Disease Pathology
Ashton, N. J., Brum, W. S., Di Molfetta, G., Benedet, A. L., Arslan, B., Jonaitis, E., Langhough, R. E., Cody, K., Wilson, R., Carlsson, C. M., et al. (2024) · JAMA Neurology · doi:10.1001/jamaneurol.2023.5319 · Cited by 884
Self-citationHansson, O., Edelmayer, R. M., Boxer, A. L., Carrillo, M. C., Mielke, M. M., Rabinovici, G. D., Salloway, S., Sperling, R., Zetterberg, H., & Teunissen, C. E. (2022) · Alzheimer's & Dementia · doi:10.1002/alz.12756 · Cited by 607
Self-citationBlood biomarkers for Alzheimer’s disease in clinical practice and trials
Hansson, O., Blennow, K., Zetterberg, H., & Dage, J. (2023) · Nature Aging · doi:10.1038/s43587-023-00403-3 · Cited by 522
Self-citationBlood phospho-tau in Alzheimer disease: analysis, interpretation, and clinical utility
Karikari, T. K., Ashton, N. J., Brinkmalm, G., Brum, W. S., Benedet, A. L., Montoliu-Gaya, L., Lantero-Rodriguez, J., Pascoal, T. A., Suárez-Calvet, M., Rosa-Neto, P., et al. (2022) · Nature Reviews Neurology · doi:10.1038/s41582-022-00665-2 · Cited by 329
Self-citationGFAP as a Potential Biomarker for Alzheimer’s Disease: A Systematic Review and Meta-Analysis
Kim, K. Y., Shin, K. Y., & Chang, K.-A. (2023) · Cells · doi:10.3390/cells12091309 · Cited by 309
“It may be demonstrated that blood GFAP should be considered for a more robust determination of the A β burden in cognitively unimpaired people [36].”
Background
Metadata
- Authors
- Benedet, A. L., Brum, W. S., Hansson, O., Initiative, A. D. N., Karikari, T. K., Zimmer, E. R., Zetterberg, H., Blennow, K., & Ashton, N. J.
- Venue
- Alzheimer's Research & Therapy
- Published
- 2022-02-07
- Volume
- 14
- Issue
- 1
- Pages
- 26-26
- ISSN
- 1758-9193 (ISSN-L)
- OpenAlex
- W4210357094
- Cited by
- 138
- References
- 27
- FWCI
- 16.29
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The accuracy and robustness of plasma biomarker models for amyloid PET positivity. https://app.cochat.ai/papers/10.1186/s13195-021-00942-0
- The paper
- Benedet, A. L., Brum, W. S., Hansson, O., Initiative, A. D. N., Karikari, T. K., Zimmer, E. R., Zetterberg, H., Blennow, K., & Ashton, N. J. (2022). The accuracy and robustness of plasma biomarker models for amyloid PET positivity. Alzheimer's Research & Therapy. https://doi.org/10.1186/s13195-021-00942-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.