IDAC-Dose 2.1, an internal dosimetry program for diagnostic nuclear medicine based on the ICRP adult reference voxel phantoms
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
To date, the estimated radiation-absorbed dose to organs and tissues in patients undergoing diagnostic examinations in nuclear medicine is derived via calculations based on models of the human body and the biokinetic behaviour of the radiopharmaceutical. An internal dosimetry computer program, IDAC-Dose2.1, was developed based on the International Commission on Radiological Protection (ICRP)-specific absorbed fractions and computational framework of internal dose assessment given for reference adults in ICRP Publication 133. The program uses the radionuclide decay database of ICRP Publication 107 and considers 83 different source regions irradiating 47 target tissues, defining the effective dose as presented in ICRP Publications 60 and 103. The computer program was validated against another ICRP dosimetry program, Dose and Risk Calculation (DCAL), that employs the same computational framework in evaluation of occupational and environmental intakes of radionuclides. IDAC-Dose2.1 has a sub-module for absorbed dose calculations in spherical structures of different volumes and composition; this sub-module is intended for absorbed dose estimates in radiopharmaceutical therapy. For nine specific alpha emitters, the absorbed dose contribution from their decay products is also included in the committed absorbed dose calculations. The absorbed doses and effective dose of 131I-iodide determined by IDAC-Dose2.1 were validated against the dosimetry program DCAL, showing identical results. IDAC-Dose2.1 was used to calculate absorbed doses for intravenously administered 18F-FDG and orally administered 99mTc-pertechnetate and 131I-iodide, three frequently used radiopharmaceuticals. Using the tissue weighting factors from ICRP Publication 103, the effective dose per administered activity was estimated to be 0.016 mSv/MBq for 18F-FDG, 0.014 mSv/MBq for 99mTc-pertechnetate, and 16 mSv/MBq for 131I-iodide. The internal dosimetry program IDAC-Dose2.1 was developed and applied to three radiopharmaceuticals for validation against DCAL and to generate improved absorbed dose estimations for diagnostic nuclear medicine using specific absorbed fraction values of the ICRP computational voxel phantoms. The sub-module for absorbed dose calculations in spherical structures 1 mm to 9 cm in diameter and different tissue composition was included to broaden the clinical usefulness of the program. The IDAC-Dose2.1 program is free software for research and available for download at http://www.idac-dose.org .
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recommendations of the International Commission on Radiological Protection
(1961) · Postgraduate Medical Journal · doi:10.1136/pgmj.37.425.168-b · Cited by 5,862
FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0
Boellaard, R., Delgado-Bolton, R., Oyen, W. J. G., Giammarile, F., Tatsch, K., Eschner, W., Verzijlbergen, F. J., Barrington, S. F., Pike, L. C., Weber, W. A., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-014-2961-x · Cited by 3,303 · cited 1×
“5 min per bed position [35] for a patient weighing 73 kg, the absorbed dose was calculated for 290 MBq of administered activity.”
Preface, Executive Summary and Glossary
(2007) · Annals of the ICRP · doi:10.1016/j.icrp.2007.10.003 · Cited by 2,106
Valentin, J. (2002) · Annals of the ICRP · doi:10.1016/s0146-6453(03)00002-2 · Cited by 1,754
Report of the task group on reference man
(1979) · Annals of the ICRP · doi:10.1016/0146-6453(79)90123-4 · Cited by 1,706 · cited 1×
“0 were based on the stylised family anatomical phantoms described by Cristy and Eckerman [16] and based on the data given in ICRP Publication 23 for the “Reference Man” [17].”
MethodTask Group of Committee 2 (1995) · Annals of the ICRP · doi:10.1016/s0146-6453(00)80008-1 · Cited by 1,369
Stabin, M. G., Sparks, R. B., & Crowe, E. A. (2005) · PubMed · Cited by 1,350
ICRP Publication 103, The Recommendations of the International Commission on Radiological Protection
Vetter, R. J. (2008) · Health Physics · doi:10.1097/01.hp.0000324200.73903.5b · Cited by 1,263
Initial MCNP6 Release Overview
Goorley, T., James, M., Booth, T., Brown, F., Bull, J., Cox, L. J., Durkee, J., Elson, J., Fensin, M., Forster, R. A., et al. (2012) · Nuclear Technology · doi:10.13182/nt11-135 · Cited by 1,181
Bolch, W. E., Eckerman, K. F., Sgouros, G., & Thomas, S. R. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.056036 · Cited by 913 · cited 1×
“MIRD pamphlet 21 [27] defines the mean absorbed dose (D) to a target region (rT) for a time-independent system as Eq.”
BackgroundSelf-citationICRP Publication 119: Compendium of Dose Coefficients based on ICRP Publication 60
Eckerman, K., Harrison, J., Menzel, H.-G., & Clement, C. H. (2012) · Annals of the ICRP · doi:10.1016/j.icrp.2012.06.038 · Cited by 706
Self-citationSpecific absorbed fractions of energy at various ages from internal photon sources: 6, Newborn
Cristy, M., & Eckerman, K. F. (1987) · doi:10.2172/6202949 · Cited by 692
Self-citationRadiation Protection in Medicine
(2007) · Annals of the ICRP · doi:10.1016/j.icrp.2008.07.001 · Cited by 641
MIRDOSE: Personal Computer Software for Internal Dose Assessment in Nuclear Medicine
Piwnica-Worms, D. (1996) · Cited by 500
Realistic reference phantoms: An ICRP/ICRU joint effort
(2009) · Annals of the ICRP · doi:10.1016/j.icrp.2009.09.001 · Cited by 496
Mattsson, S., Johansson, L. F., Svegborn, S. L., Liniecki, J., Noßke, D., Riklund, K., Stabin, M. G., Taylor, D. M., Bolch, W. E., Carlsson, S., et al. (2015) · Annals of the ICRP · doi:10.1177/0146645314558019 · Cited by 437
Self-citationRadionuclide Transformations : Energy and Intensity of Emissions.
Icrp (1983) · Cited by 416
(2008) · Annals of the ICRP · doi:10.1016/j.icrp.2008.08.003 · Cited by 390
Specific absorbed fractions of energy at various ages from internal photon sources: 1, Methods
Cristy, M., & Eckerman, K. F. (1987) · doi:10.2172/6233735 · Cited by 310
Self-citationRadiation Dose to Patients from Radiopharmaceuticals
Task Group of Committee 2 (1987) · Annals of the ICRP · doi:10.1016/0146-6453(87)90003-0 · Cited by 234
Bolch, W. E., Jokisch, D., Zankl, M., Eckerman, K. F., Fell, T., Manger, R., Endo, A., Hunt, J., Kim, K. P., & Petoussi-Henss, N. (2016) · Annals of the ICRP · doi:10.1177/0146645316661077 · Cited by 176
Self-citationICRP Publication 134: Occupational Intakes of Radionuclides: Part 2
Paquet, F., Bailey, M. R., Leggett, R. W., Lipsztein, J. L., Fell, T. P., Smith, T. J., Noßke, D., Eckerman, K. F., Berkovski, V., Ansoborlo, É., et al. (2016) · Annals of the ICRP · doi:10.1177/0146645316670045 · Cited by 148
Self-citationA Physiological Systems Model for Iodine for Use in Radiation Protection
Leggett, R. W. (2010) · Radiation Research · doi:10.1667/rr2243.1 · Cited by 89 · cited 7×
“Eckerman K, Leggett R, Cristy M, Nelson C, Ryman J, Sjoreen A, Ward R. DCAL: User's guide to the DCAL system.”
MethodInfluentialAndersson, M., Johansson, L. F., Minarik, D., Leide-Svegborn, S., & Mattsson, S. (2014) · EJNMMI Physics · doi:10.1186/2197-7364-1-9 · Cited by 87 · cited 1×
“019 mSv/MBq [39, 40], respectively, which is in satisfactory agreement with the 0.”
ResultSelf-citationMedical Radionuclides. Radiation Dose and Effects
Cormack, D. V., Cloutier, R. J., Edwards, C. L., & Snyder, W. S. (1970) · Radiation Research · doi:10.2307/3573219 · Cited by 44
Andersson, M., Johansson, L., Minarik, D., Mattsson, S., & Leide-Svegborn, S. (2013) · Radiation Protection Dosimetry · doi:10.1093/rpd/nct337 · Cited by 34 · cited 1×
“0 [23] created to calculate absorbed dose based on earlier published SAF values [24] for the ICRP adult computational voxel phantoms [20].”
MethodSelf-citationHadid‐Beurrier, L., Gardumi, A., & Desbrée, A. (2013) · Radiation Protection Dosimetry · doi:10.1093/rpd/nct049 · Cited by 34
Andersson, M. (2015) · EJNMMI Physics · doi:10.1186/s40658-015-0121-4 · Cited by 20 · cited 1×
“019 mSv/MBq [39, 40], respectively, which is in satisfactory agreement with the 0.”
ResultSelf-citationA biokinetic model for systemic technetium in adult humans
Leggett, R. W., & Giussani, A. (2015) · Journal of Radiological Protection · doi:10.1088/0952-4746/35/2/297 · Cited by 14 · cited 4×
“The technetium model by Leggett and Giussani is not based solely on data for pertechnetate, as clinical data often show minor uptake in the liver due to the uptake of 99Mo-molybdate present in small amounts in the generatorproduced pertechnetate.”
MethodInfluential
Cited by
Giesel, F. L., Kratochwil, C., Lindner, T., Marschalek, M. M., Loktev, A., Lehnert, W., Debus, J., Jäger, D., Flechsig, P., Altmann, A., et al. (2019) · Journal of Nuclear Medicine · doi:10.2967/jnumed.118.215913 · Cited by 740
Auger electrons for cancer therapy – a review
Ku, A., Facca, V. J., Cai, Z., & Reilly, R. M. (2019) · EJNMMI Radiopharmacy and Chemistry · doi:10.1186/s41181-019-0075-2 · Cited by 643
Giesel, F. L., Adeberg, S., Syed, M., Lindner, T., Jiménez-Franco, L. D., Mavriopoulou, E., Staudinger, F., Tonndorf-Martini, E., Regnery, S., Rieken, S., et al. (2021) · Journal of Nuclear Medicine · doi:10.2967/jnumed.120.245084 · Cited by 302
Sjögreen Gleisner, K., Chouin, N., Gabina, P. M., Cicone, F., Gnesin, S., Stokke, C., Konijnenberg, M., Cremonesi, M., Verburg, F. A., Bernhardt, P., et al. (2022) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-022-05727-7 · Cited by 252
Metadata
- Authors
- Andersson, M., Johansson, L., Eckerman, K., & Mattsson, S.
- Venue
- EJNMMI Research
- Published
- 2017-11-03
- Volume
- 7
- Issue
- 1
- Pages
- 88-88
- ISSN
- 2191-219X (ISSN-L)
- OpenAlex
- W2766416509
- Cited by
- 230
- References
- 30
- FWCI
- 7.19
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.