Head-to-head comparison of image quality between brain 18F-FDG images recorded with a fully digital versus a last-generation analog PET camera
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
The quality of phantom images was previously shown to be higher on digital (Vereos Philips®) compared to analog PET (Ingenuity Philips®) cameras. This study aimed to determine the extent to which this difference still remains significant on normal brain 18 F-FDG PET images. Relative noise and contrast as well as border sharpness (a spatial resolution index) of central (striata) and peripheral (occiput) gray-matter structures were compared between 10 sets of normal brain 18 F-FDG PET images recorded and reconstructed on digital and analog last-generation PET cameras, together with a subjective visual analysis of image quality provided by experienced physicians. Compared with analog PET, digital PET provided marked improvements in image quality parameters. The median relative noise was decreased (− 22%), while gray/white-matter contrast was increased (+ 27%/+ 41% for central/peripheral gray-matter structures), with these results being consistent with visual analysis. In addition, a clear enhancement in image sharpness was further documented for digital PET owing to the possible use of a 1-mm 3 voxel size (+ 24%/+ 21%). On normal brain 18 F-FDG images and compared with a last-generation analog PET, the fully digital PET camera offers marked improvements in image noise and contrast, as well as significant potential for further enhancing spatial resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“However, adequately defined quantitative assessments may each measure specific aspects of subjective image quality, such as image sharpness, lesion contrast or image noise [178].”
From Influences on PET Quantification and Interpretation (2022) · cites this paper as [178]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bayesian-Based Iterative Method of Image Restoration*
Richardson, W. H. (1972) · Journal of the Optical Society of America · doi:10.1364/josa.62.000055 · Cited by 4,160
An iterative technique for the rectification of observed distributions
Lucy, L. B. (1974) · The Astronomical Journal · doi:10.1086/111605 · Cited by 3,866
Peli, E. (1990) · Journal of the Optical Society of America A · doi:10.1364/josaa.7.002032 · Cited by 1,298
Peli, E. (1988) · Annual Meeting Optical Society of America · doi:10.1364/oam.1988.fd8 · Cited by 937
National electrical manufacturers association
(1926) · Journal of the A.I.E.E. · doi:10.1109/jaiee.1926.6537344 · Cited by 860
Recent developments in time-of-flight PET
Vandenberghe, S., Mikhaylova, E., D’Hoe, E., Mollet, P., & Karp, J. S. (2016) · EJNMMI Physics · doi:10.1186/s40658-016-0138-3 · Cited by 368
Focus on time-of-flight PET: the benefits of improved time resolution
Conti, M. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1711-y · Cited by 335
The digital silicon photomultiplier — Principle of operation and intrinsic detector performance
Frach, T., Prescher, G., Degenhardt, C., de Gruyter, R., Schmitz, A., & Ballizany, R. (2009) · 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) · doi:10.1109/nssmic.2009.5402143 · Cited by 317
Time-of-flight positron emission tomography: status relative to conventional PET.
Budinger, T. F. (1983) · PubMed · Cited by 283
Imbert, L., Poussier, S., Franken, P. R., Songy, B., Verger, A., Morel, O., Wolf, D., Noel, A., Karcher, G., & Marie, P.-Y. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.107417 · Cited by 267
Self-citation
Research works printed but not linked: 1
- NationalElectricalManufacturersAssociation NEMA NU-2 2012: performance measurement of positron emission tomography 2013
Cited by
EANM procedure guidelines for brain PET imaging using [18F]FDG, version 3
Guedj, E., Varrone, A., Boellaard, R., Albert, N. L., Barthel, H., van Berckel, B., Brendel, M., Cecchin, D., Ekmekcioglu, O., Garibotto, V., et al. (2022) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-021-05603-w · Cited by 300
PET Imaging in Neuro-Oncology: An Update and Overview of a Rapidly Growing Area
Verger, A., Kas, A., Darcourt, J., & Guedj, É. (2022) · Cancers · doi:10.3390/cancers14051103 · Cited by 78
“With marked improvements in image signal-to-noise ratios as well as significant potential for further enhancement of spatial resolution, fully digital PET cameras offer high performances for brain PET imaging [130].”
BackgroundSelf-citationEANM practice guidelines for an appropriate use of PET and SPECT for patients with epilepsy
Traub‐Weidinger, T., Arbizu, J., Barthel, H., Boellaard, R., Borgwardt, L., Brendel, M., Cecchin, D., Chassoux, F., Fraioli, F., Garibotto, V., et al. (2024) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-024-06656-3 · Cited by 82
“…has been given both by the introduction of digital PET, which provides better image quality, diagnostic confidence and accuracy than analogue PET [64], and from hybrid PET/MRI systems, thanks to their simultaneous multimodal acquisition resulting in a perfect image fit with good surgical outcome…”
BackgroundSelf-citation18F-FDOPA PET for the Noninvasive Prediction of Glioma Molecular Parameters: A Radiomics Study
Zaragori, T., Oster, J., Roch, V., Hossu, G., Chawki, M. B., Grignon, R., Pouget, C., Gauchotte, G., Rech, F., Blonski, M., et al. (2021) · Journal of Nuclear Medicine · doi:10.2967/jnumed.120.261545 · Cited by 72
“The digital static images were reconstructed using the time-of-flight information and a high-resolution protocol with the ordered-subsets expectation maximization 3-dimensional algorithm (2 iterations, 10 subsets, a deconvolution of the point-spread function) and 256 3 256 3 164 voxels of 1 3 1 3 1 mm, whereas a proto…”
MethodSelf-citationInfluences on PET Quantification and Interpretation
Rogasch, J. M. M., Hofheinz, F., van Heek, L., Voltin, C.-A., Boellaard, R., & Kobe, C. (2022) · Diagnostics · doi:10.3390/diagnostics12020451 · Cited by 57
SNMMI Procedure Standard/EANM Practice Guideline for Brain [ 18 F]FDG PET Imaging, Version 2.0
Arbizu, J., Morbelli, S. D., Minoshima, S., Barthel, H., Kuo, P. H., Weehaeghe, D. V., Horner, N., Colletti, P. M., & Guedj, É. (2024) · Journal of Nuclear Medicine · doi:10.2967/jnumed.124.268754 · Cited by 76
A role of FDG-PET/CT for response evaluation in metastatic breast cancer?
Hildebrandt, M. G., Naghavi‐Behzad, M., & Vogsen, M. (2022) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2022.03.004 · Cited by 59
Salvadori, J., Odille, F., Verger, A., Olivier, P., Karcher, G., Marie, P., & Imbert, L. (2020) · EJNMMI Physics · doi:10.1186/s40658-020-0281-8 · Cited by 60
Self-citationDigital PET vs Analog PET: Clinical Implications?
López-Mora, D. A., Carrió, I., & Flotats, A. (2021) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2021.10.004 · Cited by 54
Verger, A., Doyen, M., Campion, J., & Guedj, É. (2021) · EJNMMI Research · doi:10.1186/s13550-021-00771-0 · Cited by 53
Self-citationVerger, A., Grimaldi, S., Ribeiro, M. J., Frismand, S., & Guedj, É. (2021) · Annals of Neurology · doi:10.1002/ana.26187 · Cited by 53
“The concomitant evolution of PET systems and digital PET technologies now offers marked improvements in image signal/noise ratios and contrast, and has significant potential for further enhancing spatial resolution.(42) Digital PET systems using silicon photomultipliers improve timeof-flight resolution, which facilita…”
BackgroundSelf-citationBordonné, M., Chawki, M. B., Marie, P., Zaragori, T., Roch, V., Grignon, R., Imbert, L., & Verger, A. (2020) · EJNMMI Physics · doi:10.1186/s40658-020-00334-7 · Cited by 51
Self-citationHow fast can we scan patients with modern (digital) PET/CT systems?
Lasnon, C., Coudrais, N., Houdu, B., Nganoa, C., Salomon, T., Enilorac, B., & Aide, N. (2020) · European Journal of Radiology · doi:10.1016/j.ejrad.2020.109144 · Cited by 42
Monte Carlo simulation of digital photon counting PET
Salvadori, J., Labour, J., Odille, F., Marie, P., Badel, J., Imbert, L., & Sarrut, D. (2020) · EJNMMI Physics · doi:10.1186/s40658-020-00288-w · Cited by 42
Self-citationWagatsuma, K., Sakata, M., Ishibashi, K., Hirayama, A., Kawakami, H., Miwa, K., Suzuki, Y., & Ishii, K. (2020) · EJNMMI Physics · doi:10.1186/s40658-020-00337-4 · Cited by 29
Salvadori, J., Odille, F., Karcher, G., Marie, P., & Imbert, L. (2021) · EJNMMI Physics · doi:10.1186/s40658-020-00344-5 · Cited by 28
Self-citationSeeing Is Believing: Nuclear Imaging of HIV Persistence
Henrich, T. J., Hsue, P. Y., & VanBrocklin, H. F. (2019) · Frontiers in Immunology · doi:10.3389/fimmu.2019.02077 · Cited by 24
“These systems have led to improvements in signal-to-noise ratios and enhancing image contrast (137, 138) and may play an important role in improving PET imaging in HIV infection.”
Digital versus analog PET/CT in patients with known or suspected liver metastases
Fuentes-Ocampo, F., López-Mora, D. A., Flotats, A., Camacho, V., Sizova, M., Abouzian, S., Duch, J., Fernández, A. F., Estorch, M., & Carrió, I. (2020) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000001341 · Cited by 11
Oddstig, J., Brolin, G., Trägårdh, E., & Minarik, D. (2021) · EJNMMI Physics · doi:10.1186/s40658-021-00366-7 · Cited by 10
“Previous studies comparing scanners with SiPM-technology to conventional analogue PET/CT-systems have studied phantoms with large spheres or brain phantom [3, 10].”
BackgroundAhrari, S., Zaragori, T., Bros, M., Oster, J., Imbert, L., & Verger, A. (2022) · Cancers · doi:10.3390/cancers14235765 · Cited by 12
“One static image based on the last 20 min of the acquisition (2 iterations, 10 subsets, 256 × 256 × 164 voxels of 1 × 1 × 1 mm3) and 30 frames of 1 min each (3 iterations, 15 subsets, 128 × 128 × 82 voxels of 2 × 2 × 2 mm3) for dynamic images were reconstructed using an OSEM 3D algorithm [16,20].”
MethodSelf-citationDynamic 18F-FDopa PET Imaging for Newly Diagnosed Gliomas: Is a Semiquantitative Model Sufficient?
Zaragori, T., Doyen, M., Rech, F., Blonski, M., Taillandier, L., Imbert, L., & Verger, A. (2021) · Frontiers in Oncology · doi:10.3389/fonc.2021.735257 · Cited by 8
“, three iterations, 15 subsets, without PSF, and 128 × 128 × 82 voxels of 2 × 2 × 2 mm(3) (25).”
Self-citationNaghavi‐Behzad, M., Vogsen, M., Gerke, O., Dahlsgaard-Wallenius, S. E., Nissen, H. J., Jakobsen, N. M., Braad, P., Vilstrup, M. H., Deak, P. D., Hildebrandt, M. G., et al. (2023) · Journal of Imaging · doi:10.3390/jimaging9030065 · Cited by 7
“This leads to a considerable improvement in image contrast and noise level [5,6], which could provide better diagnostic accuracy and overall image quality, compared with analog PET/CT scanners [3,4,7,8].”
BackgroundMairal, E., Doyen, M., Jonveaux, T., Malaplate, C., Guedj, É., & Verger, A. (2020) · EJNMMI Research · doi:10.1186/s13550-020-00733-y · Cited by 7
Self-citationInvestigation of the effectiveness of no-reference metric in image evaluation in nuclear medicine
Higashiyama, S., Katayama, Y., Yoshida, A., Inoue, N., Yamanaga, T., Ichida, T., Miki, Y., & Kawabe, J. (2024) · PLoS ONE · doi:10.1371/journal.pone.0310305 · Cited by 8
Rovera, G., Urso, L., Stracuzzi, F., Laudicella, R., Frantellizzi, V., Cottignoli, C., Gazzilli, M., Guglielmo, P., Panareo, S., Evangelista, L., et al. (2024) · Clinical and Translational Imaging · doi:10.1007/s40336-024-00650-3 · Cited by 5
“Therefore, proper control databases for semi-quantitative analysis of dPET imaging need to be established to ensure accurate diagnoses while fully taking advantage of the enhanced image quality of dPET imaging [ 52 , 55].”
InfluentialShao, H., Huang, G., Wang, Y., Zhang, Y., Xue, Q., Hao, J., & Liu, J. (2025) · Human Brain Mapping · doi:10.1002/hbm.70292 · Cited by 3
“The sharpness index values and are expressed in percentage of the maximal count value of the line (Salvadori et al. 2019).”
Rovera, G., Urso, L., Stracuzzi, F., Laudicella, R., Frantellizzi, V., Cottignoli, C., Gazzilli, M., Guglielmo, P., Panareo, S., Evangelista, L., et al. (2024) · Clinical and Translational Imaging · doi:10.1007/s40336-024-00653-0 · Cited by 4
Suzuki, M., Fushimi, Y., Okada, T., Hinoda, T., Nakamoto, R., Arakawa, Y., Sawamoto, N., Togashi, K., & Nakamoto, Y. (2021) · Japanese Journal of Radiology · doi:10.1007/s11604-021-01105-9 · Cited by 4
Promising Advances for Imaging Lung Macrophage Recruitment
Chen, D. L. (2019) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201907-1455ed · Cited by 3
“head to toe within minutes, will provide improved sensitivity and spatial resolution that can enable improved characterization of novel PET tracers in the lungs in humans (8, 9).”
BackgroundNaeimi, A., Harsini, S., Aghdam, R. A., Klein, R., & Abbaspour, F. (2025) · Frontiers in Oncology · doi:10.3389/fonc.2025.1597919 · Cited by 1
Ueda, T., Yamashita, K., Kawazoe, R., Sayawaki, Y., Morisawa, Y., Kamezaki, R., Ikeda, R., Shiraishi, S., Uchiyama, Y., & Ito, S. (2024) · PubMed Central · doi:10.22038/aojnmb.2024.74875.1522 · Cited by 4
Mikami, S., Nakamura, F., Nakamura, A., & Torizuka, T. (2021) · Japanese Journal of Radiological Technology · doi:10.6009/jjrt.2021_jsrt_77.5.454 · Cited by 2
Higashiyama, S., Katayama, Y., Yoshida, A., Inoue, N., Yamanaga, T., Kawahata, H., Ichida, T., Miki, Y., & Kawabe, J. (2021) · Research Square · doi:10.21203/rs.3.rs-372416/v1 · Cited by 1
Methionine PET – overview and application to brain tumour imaging and treatment
Kardan, A., Choi, S., Satter, M. R., Sloan, A. E., & Muzic, R. F. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-822835-7.00066-4
[PET] 1. Characteristics and Clinical Applications of SiPM-based PET System
Magota, K., & Shinyama, D. (2022) · Japanese Journal of Radiological Technology · doi:10.6009/jjrt.2022-2129
Dahal, T., & Nepal, B. (2023) · IP Indian Journal of Anatomy and Surgery of Head Neck and Brain · doi:10.18231/j.ijashnb.2023.017 · Cited by 1
Exploration des mouvements anormaux : état des lieux
Querellou, S., Payoux, P., Verger, A., Darcourt, J., & Guedj, É. (2024) · Médecine Nucléaire · doi:10.1016/j.mednuc.2024.01.186
Self-citationEndo, H., Hirata, K., Magota, K., Yoshimura, T., Katoh, C., & Kudo, K. (2025) · EJNMMI Physics · doi:10.1186/s40658-025-00791-y
Fang, L., Yuan, X., Fang, Q., Xu, F., Hong, R., Li, B., Zhang, B., Li, A., Zhang, W., Xiao, P., et al. (2025) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2025.3629097
“In this study, convergence was defined by the contrast recovery coefficient (CRC) of the smallest 10 mm hot sphere [34].”
InfluentialSalvadori, J., Odille, F., Karcher, G., Marie, P., & Imbert, L. (2021) · Figshare · doi:10.6084/m9.figshare.13532507
Self-citationSalvadori, J., Odille, F., Karcher, G., Marie, P., & Imbert, L. (2021) · Figshare · doi:10.6084/m9.figshare.13532513
Self-citationInterictal PET and Its Value in the Localization of the Seizure-Onset Zone
Tolboom, N., Meurs, A., & Weehaeghe, D. V. (2026) · Springer eBooks · doi:10.1007/978-3-032-04182-1_8
Caractérisation, optimisation et simulation des performances d’un TEP-TDM numérique
Salvadori, J. (2020) · theses.fr (ABES) · doi:10.70675/395dd2fez72dez460azb30azcd415240b3f8 · Cited by 5
Self-citationLabour, J. (2021) · theses.fr (ABES) · doi:10.70675/0e5c95eez80a1z4756za08fz42445b192038 · Cited by 1
Metadata
- Authors
- Salvadori, J., Imbert, L., Perrin, M., Karcher, G., Lamiral, Z., Marie, P.-Y., & Verger, A.
- Affiliations
- Inserm (FR)
- Centre Hospitalier Régional et Universitaire de Nancy (FR)
- Corresponding author
- Salvadori, Julien
- Venue
- EJNMMI Research
- Published
- 2019-07-12
- Volume
- 9
- Issue
- 1
- Pages
- 61-61
- ISSN
- 2191-219X (ISSN-L)
- PMC
- PMC6626093
- OpenAlex
- W2960451160
- Cited by
- 44
- References
- 18
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 7 · 2023: 2 · 2022: 6 · 2021: 14 · 2020: 8 · 2019: 2
- FWCI
- 4.96
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- EJNMMI Research (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- HAL (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Keywords
- digital PET, 18F-FDG PET, neuroimaging, image quality, image noise, gray-white matter contrast, spatial resolution, voxel size, ingenuity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.