The use of a proposed updated EARL harmonization of 18F-FDG PET-CT in patients with lymphoma yields significant differences in Deauville score compared with current EARL recommendations
Open accessAbstract
The Deauville score (DS) is a clinical tool, based on the comparison between lesion and reference organ uptake of 18 F-fluorodeoxyglucose (FDG), used to stratify patients with lymphoma into categories reflecting their disease status. With a plethora of positron emission tomography with computed tomography (PET-CT) hard- and software algorithms, standard uptake value (SUV) in lesions and reference organs may differ which affects DS classification and therefore medical treatment. The EANM Research Ltd. (EARL) harmonization program from the European Association of Nuclear Medicine (EANM) partly mitigates this issue, but local preferences are common in clinical practice. We have investigated the discordance in DS calculated from patients with lymphoma referred for 18 F-FDG PET-CT reconstructed with three different algorithms: the newly introduced block-sequential regularization expectation-maximization algorithm commercially sold as Q. Clear (QC, GE Healthcare, Milwaukee, WI, USA), compliant with the newly proposed updated EARL recommendations, and two settings compliant with the current EARL recommendations (EARL lower and EARL upper , representing the lower and upper limit of the EARL recommendations). Fifty-two patients with non-Hodgkin and Hodgkin lymphoma were included (18 females and 34 males). Segmentation of mediastinal blood pool and liver were semi-automatically performed, whereas segmentation of lesions was done manually. From these segmentations, SUV max and SUV peak were obtained and DS calculated. There was a significant difference in DS between the QC algorithm and EARL lower /EARL upper ( p < 0.0001 for both) but not between EARL lower and EARL upper ( p = 0.102) when SUV max was used. For SUV peak , there was a significant difference between QC and EARL lower ( p = 0.001), but not for QC vs EARL upper ( p = 0.071) or EARL lower vs EARL upper ( p = 0.102). Five non-responders (DS 4–5) for QC were classified as responders (DS 1–3) when EARL lower /EARL upper was used, both when SUV max and SUV peak were investigated. Using the proposed updated EARL recommendations compared with the current recommendations will significantly change DS classification. In select cases, the discordance would affect the choice of medical treatment. Specifically, the current EARL recommendations were more often prone to classify patients as responders.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In a study on 52 patients with lymphoma, 5 patients undergoing [18F]FDG-PET for restaging were divergently classified as non-responders (Deauville score 4-5) with PL reconstruction but as responders (Deauville 1-3) with OSEM.
“In a study on 52 patients with lymphoma, 5 patients undergoing [18F]FDG-PET for restaging were divergently classified as non-responders (Deauville score 4–5) with PL reconstruction but as responders (Deauville 1–3) with OSEM (without TOF or PSF; compliant with the EARL1 standard) [176].”
From Influences on PET Quantification and Interpretation (2022) · cites this paper as [176]
The Results (Patients and Quantitative analysis; pages unavailable) report 52 patients and five QC non-responders (Deauville 4–5) classified as responders (Deauville 2–3) with EARL reconstruction. The Methods (PET-CT acquisition and reconstruction parameters; page unavailable) identify QC as Q.Clear and the EARL reconstructions as OSEM without resolution recovery or time of flight. The study included baseline, interim, end-of-treatment and suspected-recurrence scans; it does not identify all five reclassified patients as undergoing restaging. (LLM, conf=0.84)
Experimental — accuracy not yet measuredBoth SUV measurements and visual Deauville criteria may be affected by image reconstruction, such as PL reconstruction.
“However, both SUV measurements and visual Deauville criteria may be affected by image reconstruction, such as PL reconstruction [176].”
From Influences on PET Quantification and Interpretation (2022) · cites this paper as [176]
The Methods (PET-CT acquisition and reconstruction parameters; Image analysis) compare different reconstruction algorithms and calculate Deauville scores from SUVmax and SUVpeak. The Results (Quantitative analysis) show that those scores can differ by reconstruction. The paper does not assess visually assigned Deauville criteria, so that part of the claim is not established. (LLM, conf=0.86)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Cheson, B. D., Fisher, R. I., Barrington, S. F., Cavalli, F., Schwartz, L. H., Zucca, E., & Lister, T. A. (2014) · Journal of Clinical Oncology · doi:10.1200/jco.2013.54.8800 · Cited by 5,715 · see citing works
FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0
Boellaard, R., Delgado-Bolton, R., Oyen, W. J. G., Giammarile, F., Tatsch, K., Eschner, W., Verzijlbergen, F. J., Barrington, S. F., Pike, L. C., Weber, W. A., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-014-2961-x · Cited by 3,303 · see citing works
Appio, L., Landoni, C., Latargia, M. L., Bertolli, V. G., Chiarucci, M., Crovetti, G., Vassenna, E., Serio, G., & Bregni, M. (2017) · Chemotherapy · doi:10.1159/000458147 · Cited by 2,327 · see citing works
Barrington, S. F., Qian, W., Somer, E. J., Franceschetto, A., Bagni, B., Brun, E., Almquist, H., Loft, A., Højgaard, L., Federico, M., et al. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1490-5 · Cited by 347 · see citing works
Aide, N., Lasnon, C., Veit-Haibach, P., Sera, T., Sattler, B., & Boellaard, R. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3740-2 · Cited by 344 · see citing works
Biggi, A., Gallamini, A., Chauvie, S., Hutchings, M., Kostakoğlu, L., Gregianin, M., Meignan, M. A., Małkowski, B., Hofman, M. S., & Barrington, S. F. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.110890 · Cited by 308 · see citing works
FDG PET for therapy monitoring in Hodgkin and non-Hodgkin lymphomas
Barrington, S. F., & Kluge, R. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3690-8 · Cited by 281 · see citing works
Studies of a Next-Generation Silicon-Photomultiplier–Based Time-of-Flight PET/CT System
Hsu, D. F. C., Ilan, E., Peterson, W. T., Uribe, J., Lubberink, M., & Levin, C. S. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.189514 · Cited by 241 · see citing works
Quantification, improvement, and harmonization of small lesion detection with state-of-the-art PET
van der Vos, C. S., Koopman, D., Rijnsdorp, S., Arends, A. J., Boellaard, R., van Dalen, J. A., Lubberink, M., Willemsen, A. T. M., & Visser, E. P. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3727-z · Cited by 206 · see citing works
Barrington, S. F., Kirkwood, A. A., Franceschetto, A., FULHAM, M. J., Roberts, T. H., Almquist, H., Brun, E., Hjorthaug, K., Viney, Z., Pike, L. C., et al. (2016) · Blood · doi:10.1182/blood-2015-11-679407 · Cited by 187 · see citing works
Feasibility of state of the art PET/CT systems performance harmonisation
Kaalep, A., Sera, T., Rijnsdorp, S., Yaqub, M., Talsma, A., Lodge, M. A., & Boellaard, R. (2018) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-3977-4 · Cited by 160 · see citing works
Sher, A., Lacoeuille, F., Fosse, P., Vervueren, L., Cahouet-Vannier, A., Dabli, D., Bouchet, F., & Couturier, O. (2016) · EJNMMI Research · doi:10.1186/s13550-016-0177-8 · Cited by 111 · see citing works
Point-spread function reconstructed PET images of sub-centimeter lesions are not quantitative
Munk, O. L., Tolbod, L. P., Hansen, S. B., & Bogsrud, T. V. (2017) · EJNMMI Physics · doi:10.1186/s40658-016-0169-9 · Cited by 84 · see citing works
Does PET Reconstruction Method Affect Deauville Score in Lymphoma Patients?
Enilorac, B., Lasnon, C., Nganoa, C., Fruchart, C., Gac, A., Damaj, G. L., & Aide, N. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.202721 · Cited by 27 · see citing works
Sadik, M., Lind, E., Polymeri, E., Enqvist, O., Ulén, J., & Trägårdh, E. (2018) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12546 · Cited by 25 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Harmonization strategies for multicenter radiomics investigations
Da‐ano, R., Visvikis, D., & Hatt, M. (2020) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aba798 · Cited by 161 · see citing works
Dias, A. H., Pedersen, M. F., Danielsen, H., Munk, O. L., & Gormsen, L. C. (2020) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-020-05007-2 · Cited by 92 · see citing works
Trägårdh, E., Borrelli, P., Kaboteh, R., Gillberg, T., Ulén, J., Enqvist, O., & Edenbrandt, L. (2020) · EJNMMI Physics · doi:10.1186/s40658-020-00316-9 · Cited by 88 · see citing works
Self-citationQuantitative PET in the 2020s: a roadmap
Meikle, S. R., Sossi, V., Roncali, E., Cherry, S. R., Banati, R. B., Mankoff, D. A., Jones, T., James, M. L., Sutcliffe-Goulden, J., Ouyang, J., et al. (2020) · Physics in Medicine and Biology · doi:10.1088/1361-6560/abd4f7 · Cited by 83 · see citing works
Quantitative implications of the updated EARL 2019 PET–CT performance standards
Kaalep, A., Burggraaff, C. N., Pieplenbosch, S., Verwer, E. E., Sera, T., Zijlstra, J., Hoekstra, O. S., Oprea-Lager, D. E., & Boellaard, R. (2019) · EJNMMI Physics · doi:10.1186/s40658-019-0257-8 · Cited by 79 · see citing works
Harmonization Strategies in Multicenter MRI-Based Radiomics
Stamoulou, E., Spanakis, C., Manikis, G. C., Karanasiou, G. S., Grigoriadis, G. I., Foukakis, T., Tsiknakis, M., Fotiadis, D. I., & Kostas Marias, A. (2022) · Journal of Imaging · doi:10.3390/jimaging8110303 · Cited by 74 · see citing works
Yousefirizi, F., Klyuzhin, I. S., Joo Hyun, O., Harsini, S., Tie, X., Shiri, I., Shin, M., Lee, C., Cho, S. Y., Bradshaw, T., et al. (2024) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-024-06616-x · Cited by 57 · see citing works
Influences on PET Quantification and Interpretation
Rogasch, J. M. M., Hofheinz, F., van Heek, L., Voltin, C.-A., Boellaard, R., & Kobe, C. (2022) · Diagnostics · doi:10.3390/diagnostics12020451 · Cited by 50 · see citing works
Wyrzykowski, M., Siminiak, N., Kaźmierczak, M., Ruchała, M., & Czepczyński, R. (2020) · EJNMMI Research · doi:10.1186/s13550-020-00690-6 · Cited by 34 · see citing works
Follows, G., Barrington, S. F., Bhuller, K. S., Culligan, D. J., Cutter, D. J., Gallop‐Evans, E., Kassam, S., Osborne, W., Sadullah, S., Townsend, W. M., et al. (2022) · British Journal of Haematology · doi:10.1111/bjh.18083 · Cited by 32 · see citing works
Deep progressive learning achieves whole-body low-dose 18F-FDG PET imaging
Wang, T., Qiao, W., Wang, Y., Wang, J., Lv, Y., Dong, Y., Zheng, Q., Xing, Y. T., & Zhao, J. (2022) · EJNMMI Physics · doi:10.1186/s40658-022-00508-5 · Cited by 29 · see citing works
Pre‐treatment total metabolic tumour volumes in lymphoma: Does quantity matter?
El-Galaly, T., Villa, D., Chan, C.-A. Y., & Gormsen, L. (2022) · British Journal of Haematology · doi:10.1111/bjh.18016 · Cited by 28 · see citing works
Moving the goalposts while scoring―the dilemma posed by new PET technologies
Rogasch, J. M. M., Boellaard, R., Pike, L., Borchmann, P., Johnson, P., Wolf, J., Barrington, S. F., & Kobe, C. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-021-05403-2 · Cited by 20 · see citing works
Could normalization improve robustness of abdominal MRI radiomic features?
Giannini, V., Panić, J., Regge, D., Balestra, G., & Rosati, S. (2023) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ace4ce · Cited by 15 · see citing works
Helsen, N., WYNGAERT, T. V. D., Carp, L., de Bree, R., Vanderveken, O. M., Geeter, F. D., Maes, A., Cambier, J.-P., Spaepen, K., Martens, M. J., et al. (2020) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-020-04710-4 · Cited by 12 · see citing works
Updating PET/CT performance standards and PET/CT interpretation criteria should go hand in hand
Boellaard, R., Séra, T., Kaalep, A., Hoekstra, O. S., Barrington, S. F., & Zijlstra, J. M. (2019) · EJNMMI Research · doi:10.1186/s13550-019-0565-y · Cited by 11 · see citing works
Hornnes, C., Loft, A., Højgaard, L., & Andersen, F. L. (2021) · European Journal of Hybrid Imaging · doi:10.1186/s41824-021-00096-0 · Cited by 10 · see citing works
Korsholm, K., Overbeck, N., Dias, A. H., Loft, A., Andersen, F. L., & Fischer, B. M. (2023) · Diagnostics · doi:10.3390/diagnostics13050947 · Cited by 9 · see citing works
Chauvie, S., Bergesio, F., Ponti, E. D., Morzenti, S., Maggi, A. D., Ragazzoni, M., Chiesa, C., & Matheoud, R. (2020) · Physica Medica · doi:10.1016/j.ejmp.2020.06.002 · Cited by 7 · see citing works
Effect of Bayesian penalty likelihood algorithm on 18F-FDG PET/CT image of lymphoma
Wang, Y., Lin, L., Quan, W., Li, J., & Li, W. (2021) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000001516 · Cited by 5 · see citing works
Genc, M., Yıldırım, N., Coskun, N., Özdemir, E., & Türkölmez, Ş. (2023) · Revista Española de Medicina Nuclear e Imagen Molecular (English Edition) · doi:10.1016/j.remnie.2023.07.006 · Cited by 5 · see citing works
Cox, M. C., Jurcka, T., Arens, A. I. J., van Rijk, M. C., Kaanders, J. H. A. M., & van den Bosch, S. (2023) · EJNMMI Research · doi:10.1186/s13550-023-01042-w · Cited by 4 · see citing works
de Jong, J. G., Segbers, M., Harteveld, A. A., Bron, W. J., Valkema, R., Boellaard, R., & van Zanten, S. E. M. V. (2026) · EJNMMI Research · doi:10.1186/s13550-026-01458-0 · Cited by 2 · see citing works
Gnanananthan, P., Houghton, K., Chen, M., Khagram, P., Meshaka, R., Eccles, A., Khan, S. R., Khan, S., Naik, M., Soneji, N. D. R., et al. (2026) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000002115 · Cited by 1 · see citing works
Jiménez-Ortega, E., Agüera, R., Ureba, A., Balcerzyk, M., Wals-Zurita, A., Gómez, F. J. G., & Leal, A. (2022) · Tomography · doi:10.3390/tomography8020090 · Cited by 1 · see citing works
Digitale SPECT und PET: Klinische Konsequenzen
Rogasch, J. M. M. (2022) · Angewandte Nuklearmedizin · doi:10.1055/a-1715-5305 · Cited by 1 · see citing works
Subesinghe, M., Ilyas, H., Dunn, J., Mir, N., Duran, A., Mikhaeel, N. G., & Barrington, S. F. (2022) · Clinical Radiology · doi:10.1016/j.crad.2022.09.124
Digitale SPECT und PET: Klinische Konsequenzen
Rogasch, J. M. M. (2023) · Radiopraxis · doi:10.1055/a-1993-7420
Genc, M., Yıldırım, N., Coskun, N., Özdemir, E., & Türkölmez, Ş. (2023) · Revista Española de Medicina Nuclear e Imagen Molecular · doi:10.1016/j.remn.2023.07.002
Additional file 1 of Deep progressive learning achieves whole-body low-dose 18F-FDG PET imaging
汪太松, Qiao, W., Wang, Y., Wang, J., Lv, Y., Dong, Y., Qian, Z., Xing, Y., & Zhao, J. (2022) · Figshare · doi:10.6084/m9.figshare.21621882
Leike, T., Lima, T. V. M., Saltybaeva, N., Grünig, H., Stenger-Weisser, A., Bhure, U., Leimgruber, A., & Strobel, K. (2026) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000002135
- Authors
- Ly, J., Minarik, D., Edenbrandt, L., Wollmer, P., & Trägårdh, E.
- Affiliations
- Lund University (SE)
- Sahlgrenska University Hospital (SE)
- Corresponding author
- Ly, John
- Venue
- EJNMMI Research
- Published
- 2019-07-25
- Volume
- 9
- Issue
- 1
- Pages
- 65-65
- ISSN
- 2191-219X (ISSN-L)
- PMC
- PMC6658640
- OpenAlex
- W2963708288
- Cited by
- 31
- References
- 15
- Citations by year
- 2026: 3 · 2024: 1 · 2023: 6 · 2022: 9 · 2021: 3 · 2020: 7 · 2019: 2
- FWCI
- 3.47
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- EJNMMI Research (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Lund University Publications (Lund University) (submittedVersion)
- Funders
- Knut och Alice Wallenbergs Stiftelse
- Skåne County Council's Research and Development Foundation
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Health Sciences › Medicine › Pathology and Forensic Medicine › Lymphoma Diagnosis and Treatment
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Lung Cancer Diagnosis and Treatment
- Keywords
- Deauville score, 18F-FDG PET/CT, non-Hodgkin lymphoma, Hodgkin's disease, Q.Clear, standardized uptake value, SUVmax, SUVpeak, treatment response classification
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review