CoChat

Assessing imprecision in Cochrane systematic reviews: a comparison of GRADE and Trial Sequential Analysis

Open access

The DOI matches its Crossref record; 31 of the 32 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The evaluation of imprecision is a key dimension of the grading of the confidence in the estimate. Grading of Recommendations Assessment, Development and Evaluation (GRADE) gives recommendations on how to downgrade evidence for imprecision, but authors vary in their use. Trial Sequential Analysis (TSA) has been advocated for a more reliable assessment of imprecision. We aimed to evaluate reporting of and adherence to GRADE and to compare the assessment of imprecision of intervention effects assessed by GRADE and TSA in Cochrane systematic reviews. METHODS: In this cross-sectional study, we included 100 Cochrane reviews irrespective of type of intervention with a key dichotomous outcome meta-analyzed and assessed by GRADE. The methods and results sections of each review were assessed for adequacy of imprecision evaluation. We re-analyzed imprecision following the GRADE Handbook and the TSA Manual. RESULTS: Overall, only 13.0% of reviews stated the criteria they applied to assess imprecision. The most common dimensions were the 95% width of the confidence intervals and the optimal information size. Review authors downgraded 48.0% of key outcomes due to imprecision. When imprecision was re-analyzed following the GRADE Handbook, 64% of outcomes were downgraded. Agreement between review authors' assessment and assessment by the authors of this study was moderate (kappa 0.43, 95% confidence interval [CI] 0.23 to 0.58). TSA downgraded 69.0% outcomes due to imprecision. Agreement between review authors' GRADE assessment and TSA, irrespective of downgrading levels, was moderate (kappa 0.43, 95% CI 0.21 to 0.57). Agreement between our GRADE assessment following the Handbook and TSA was substantial (kappa 0.66, 95% CI 0.49 to 0.79). CONCLUSIONS: In a sample of Cochrane reviews, methods for assessing imprecision were rarely reported. GRADE according to Handbook guidelines and TSA led to more severe judgment of imprecision rather than GRADE adopted by reviews' authors. Cochrane initiatives to improve adherence to GRADE Handbook are warranted. TSA may transparently assist in such development.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s13643-018-0770-1

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Flow chart of systematic reviews
Fig. 1 Flow chart of systematic reviewsCC BY · PubMed Central
Fig. 2 Primary outcomes that met the OIS—number of events: comparing GRADE assessment of imprecision carried out by review authors with GRADE carried out by the authors of this article following GRADE Handbook guidelines
Fig. 2 Primary outcomes that met the OIS—number of events: comparing GRADE assessment of imprecision carried out by review authors with GRADE carried out by the authors of this article following GRADE Handbook guidelinesCC BY · PubMed Central
Fig. 3 Primary outcomes that did not meet the OIS—number of events: comparing GRADE assessment of imprecision carried out by review authors with GRADE carried out by the authors of this article following GRADE Handbook guidelines
Fig. 3 Primary outcomes that did not meet the OIS—number of events: comparing GRADE assessment of imprecision carried out by review authors with GRADE carried out by the authors of this article following GRADE Handbook guidelinesCC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 31 references

Research works printed but not linked: 3

  1. Cochrane Library [database on the Internet]. Wiley Online Library. Available from: http://onlinelibrary.wiley.com/cochranelibrary/search. Accessed Feb 2017.
  2. Chapter 5.2.4.2 Imprecision in in systematic reviews in Schünemann H BJ, Guyatt G, Oxman A, editors. GRADE handbook for grading quality of evidence and strength of recommendations. Updated October 2013. The GRADE Working Group, 2013. Available from http://guidelinedevelopment.org/handbook. Accessed Jan 2017.
  3. StataCorp Stata Statistical Software: Release 8 2003 College Station StataCorp LP

Cited by

Items 101–170 of 170

Metadata

Authors
Castellini, G., Bruschettini, M., Gianola, S., Gluud, C., & Moja, L.
Affiliations
  • University of Milan (IT)
  • Lund University (SE)
  • IRCCS Ospedale Galeazzi - Sant'Ambrogio (IT)
Corresponding author
Castellini, Greta
Venue
Systematic Reviews
Published
2018-07-28
Volume
7
Issue
1
Pages
110-110
ISSN
2046-4053 (ISSN-L)
OpenAlex
W2883720163
Cited by
161
References
32
Citations by year
2026: 10 · 2025: 12 · 2024: 21 · 2023: 20 · 2022: 28 · 2021: 25 · 2020: 15 · 2019: 19 · 2018: 11
FWCI
3.45
Type
journal article
Language
en
Open access
Licence
  • cc-by
  • creativecommons.org/licenses/by/4.0/ (tdm)
Locations
  • Systematic Reviews (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, other-oa)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Archivio Istituzionale della Ricerca (Universita Degli Studi Di Milano) (submittedVersion, other-oa)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Lund University Publications (Lund University) (submittedVersion)
Funders
Ministero della Salute (Giovani Ricercatori GR-2011-02348048)
Topics
  • Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
  • Social Sciences › Sociology and Political Science › Delphi Technique in Research
Keywords
imprecision, GRADE, trial sequential analysis, confidence in evidence, reporting quality, confidence intervals, agreement between assessment methods
MeSH terms
Cross-Sectional Studies, Epidemiology, Humans, Review Literature as Topic, Meta-Analysis as Topic, Selection Bias

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.