Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 236

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Correlation of fasting and postprandial plasma glucose with HbA1c in assessing glycemic control; systematic review and meta-analysis

Open access
Ketema, Ezra Belay, Kibret, Kelemu Tilahun · 2015 · Archives of Public Health

Abstract

BACKGROUND: Glycemic control in diabetes mellitus is a cornerstone in reducing morbidity and mortality of the disease. Achieving glycemic control or reducing hyperglycemia significantly decreases the microvascular and macrovascular complications of diabetes. Even though measurement of glycated hemoglobin (HbA1c) remains the gold standard for assessment of glycemic control, there is no consensus whether fasting or postprandial plasma glucose (PPG) is a better predictor of glycemic control in resource-poor settings when HbA1c is not available. The aim of this systematic review and meta-analysis was to summarize evidences on the significance of fasting and postprandial plasma glucose, and their correlation with HbA1c. METHODS: Relevant studies were identified through systematic search of online databases (e.g. EMBASE, MEDLINE/PubMed and Cochrane library) and manual search of bibliographies of the included studies. Original research papers describing the correlations or associations of fasting and postprandial plasma glucose with HbA1c were included. The MedCalc software was used for data entry and analysis. We used the random effect model to estimate the pooled correlations of fasting and postprandial plasma glucose with HbA1c. Heterogeneity assessment and robustness analysis was also performed. RESULT: From total 126 articles identified, 14 articles were eligible for systemic review. Eleven of these eligible studies evaluated the correlations of fasting and postprandial plasma glucose to the standard HbA1c values and used in meta-analysis. Seven of these studies (63.5 %) found better or stronger correlations between PPG and HbA1c than fasting plasma glucose (FPG). In all the studies that estimated the relative contribution FPG and PPG to the overall hyperglycemia, decreases in PPG was accounted for greater decrease in HbA1c compared with decreases in FPG value. PPG also showed a better sensitivity, specificity and positive predictive value than FPG. The pooled correlation coefficient (r) between PPG and HbA1c was 0.68 (P < 0.001, 95 % CI; 0.56-0.75) slightly higher than pooled correlation coefficient of FPG (r = 0.61(P < 0.001, 95 % CI; 0.48-0.72)). CONCLUSION: PPG has a closer association with HbA1c than FPG. Hence, PPG is better in predicting overall glycemic control in the absence of HbA1c.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s13690-015-0088-6

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 236

Metadata

Authors
Ketema, E. B., & Kibret, K. T.
Venue
Archives of Public Health
Published
2015-09-25
Volume
73
Issue
1
Pages
43-43
ISSN
  • 0778-7367 (ISSN-L)
  • 2049-3258
OpenAlex
W1934660672
Cited by
236
References
7
FWCI
2.45
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Correlation of fasting and postprandial plasma glucose with HbA1c in assessing glycemic control; systematic review and meta-analysis. https://app.cochat.ai/papers/10.1186/s13690-015-0088-6
The paper
Ketema, E. B., & Kibret, K. T. (2015). Correlation of fasting and postprandial plasma glucose with HbA1c in assessing glycemic control; systematic review and meta-analysis. Archives of Public Health. https://doi.org/10.1186/s13690-015-0088-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.