American Society for Enhanced Recovery (ASER) and Perioperative Quality Initiative (POQI) joint consensus statement on perioperative fluid management within an enhanced recovery pathway for colorectal surgery
Open accessThe DOI matches its Crossref record; 91 of the 91 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Enhanced recovery may be viewed as a comprehensive approach to improving meaningful outcomes in patients undergoing major surgery. Evidence to support enhanced recovery pathways (ERPs) is strong in patients undergoing colorectal surgery. There is some controversy about the adoption of specific elements in enhanced recovery "bundles" because the relative importance of different components of ERPs is hard to discern (a consequence of multiple simultaneous changes in clinical practice when ERPs are initiated). There is evidence that specific approaches to fluid management are better than alternatives in patients undergoing colorectal surgery; however, several specific questions remain. METHODS: In the "Perioperative Quality Initiative (POQI) Fluids" workgroup, we developed a framework broadly applicable to the perioperative management of intravenous fluid therapy in patients undergoing elective colorectal surgery within an ERP. DISCUSSION: We discussed aspects of ERPs that impact fluid management and made recommendations or suggestions on topics such as bowel preparation; preoperative oral hydration; intraoperative fluid therapy with and without devices for goal-directed fluid therapy; and type of fluid.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2000) · New England Journal of Medicine · doi:10.1056/nejm200005043421801 · Cited by 12,941
Intravenous Fluids and Acute Kidney Injury
Ding, X., Cheng, Z., & Qian, Q. (2017) · Blood Purification · doi:10.1159/000452702 · Cited by 6,827
The cochrane database of systematic reviews
Geddes, J. (1996) · Journal of Psychosomatic Research · doi:10.1016/s0022-3999(96)90063-x · Cited by 5,989
A Multicenter, Randomized, Controlled Clinical Trial of Transfusion Requirements in Critical Care
Hébert, P. C., Wells, G., Blajchman, M. A., Marshall, J., Martin, C., Pagliarello, G., Tweeddale, M., Schweitzer, I., & Yetisir, E. (1999) · New England Journal of Medicine · doi:10.1056/nejm199902113400601 · Cited by 5,187 · cited 1×
“However, we note that red blood cells have the potential for harm and blood loss should be replaced with blood products only when the risks are justified by significant anemia (Hebert et al. 1999; Hajjar et al. 2010; Carson et al. 2011).”
BackgroundIntensive insulin therapy and pentastarch resuscitation in severe sepsis
Brunkhorst, F. M., Engel, C., Bloos, F., Meier-Hellmann, A., Ragaller, M., Weiler, N., Moerer, O., Gruendling, M., Oppert, M., Grond, S., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa070716 · Cited by 2,921 · cited 1×
“Three trials—comparing synthetic colloids (hydroxyethyl starch solutions) to crystalloids in critically ill patients—found either an increased risk of death or an increased use of renal replacement therapy (Brunkhorst et al. 2008; Perner et al. 2012; Myburgh et al. 2012).”
BackgroundA Comparison of Albumin and Saline for Fluid Resuscitation in the Intensive Care Unit
(2004) · New England Journal of Medicine · doi:10.1056/nejmoa040232 · Cited by 2,872
Multimodal approach to control postoperative pathophysiology and rehabilitation
Kehlet, H. (1997) · British Journal of Anaesthesia · doi:10.1093/bja/78.5.606 · Cited by 2,827
A Multicenter, Randomized, Controlled Clinical Trial of Transfusion Requirements in Critical Care
(1999) · New England Journal of Medicine · doi:10.1056/nejm199904013401322 · Cited by 2,037
Hydroxyethyl Starch 130/0.42 versus Ringer's Acetate in Severe Sepsis
Perner, A., Haase, N., Guttormsen, A. B., Tenhunen, J., Klemenzson, G., Åneman, A., Madsen, K. R., Møller, M. H., Elkjær, J. M., Poulsen, L. M., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1204242 · Cited by 1,813
Hydroxyethyl Starch or Saline for Fluid Resuscitation in Intensive Care
Myburgh, J. A., Finfer, S., Bellomo, R., Billot, L., Cass, A., Gattas, D., Glass, P., Lipman, J., Liu, B., McArthur, C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1209759 · Cited by 1,687 · cited 1×
“Applying a modified Delphi method, designed to use the collective expertise of a diverse group of experts to answer clinical questions, we achieved consensus on several topics related to perioperative fluid management in patients undergoing colorectal surgery within the context of an ERP.”
Method
Cited by
Gustafsson, U. O., Scott, M. J., Hubner, M., Nygren, J., Demartines, N., Francis, N., Rockall, T. A., Young‐Fadok, T. M., Hill, A. G., Soop, M., et al. (2019) · World Journal of Surgery · doi:10.1007/s00268-018-4844-y · Cited by 2,119
Self-citationNelson, G., Bakkum-Gamez, J., Kalogera, E., Glaser, G., Altman, A., Meyer, L. A., Taylor, J. S., Iniesta, M., Lasala, J., Mena, G., et al. (2019) · International Journal of Gynecological Cancer · doi:10.1136/ijgc-2019-000356 · Cited by 758
Wischmeyer, P. E., Carli, F., Evans, D. C., Guilbert, S., Kozar, R., Pryor, A., Thiele, R. H., Everett, S., Grocott, M., Gan, T. J., et al. (2018) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000002743 · Cited by 485
Self-citationBollag, L., Lim, G., Sultan, P., Habib, A. S., Landau, R., Zakowski, M., Tiouririne, M., Bhambhani, S., & Carvalho, B. (2021) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000005257 · Cited by 378
Perioperative nutrition: Recommendations from the ESPEN expert group
Lobo, D. N., Gianotti, L., Adiamah, A., Barazzoni, R., Deutz, N. E. P., Dhatariya, K., Greenhaff, P. L., Hiesmayr, M., Hjort Jakobsen, D., Klek, S., et al. (2020) · Clinical Nutrition · doi:10.1016/j.clnu.2020.03.038 · Cited by 296
Self-citationPerioperative Fluid Therapy for Major Surgery
Miller, T. E., & Myles, P. S. (2019) · Anesthesiology · doi:10.1097/aln.0000000000002603 · Cited by 205
Self-citationCurrent concepts of fluid management in enhanced recovery pathways
Makaryus, R., Miller, T. E., & Gan, T. J. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2017.10.011 · Cited by 186
“Although anuria is abnormal and should be taken seriously, oliguria, however, can be a normal and expected occurrence as a result of judicious fluid management in the perioperative period.(5) Recent studies suggest 0.”
BackgroundMethodInfluentialSelf-citation
Metadata
- Authors
- Workgroup, F. T. P. Q. I. (. I., Thiele, R. H., Raghunathan, K., Brudney, C. S., Lobo, D. N., Martin, D., Senagore, A., Cannesson, M., Gan, T. J., Mythen, M. M. G., Shaw, A. D., & Miller, T. E.
- Venue
- Perioperative Medicine
- Published
- 2016-09-17
- Volume
- 5
- Issue
- 1
- Pages
- 24-24
- ISSN
- 2047-0525 (ISSN-L)
- OpenAlex
- W2414596927
- Cited by
- 197
- References
- 91
- FWCI
- 26.88
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.