The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Modern technologies for improving cleaning and disinfection of environmental surfaces in hospitals
Open accessAbstract
Experts agree that careful cleaning and disinfection of environmental surfaces are essential elements of effective infection prevention programs. However, traditional manual cleaning and disinfection practices in hospitals are often suboptimal. This is often due in part to a variety of personnel issues that many Environmental Services departments encounter. Failure to follow manufacturer's recommendations for disinfectant use and lack of antimicrobial activity of some disinfectants against healthcare-associated pathogens may also affect the efficacy of disinfection practices. Improved hydrogen peroxide-based liquid surface disinfectants and a combination product containing peracetic acid and hydrogen peroxide are effective alternatives to disinfectants currently in widespread use, and electrolyzed water (hypochlorous acid) and cold atmospheric pressure plasma show potential for use in hospitals. Creating "self-disinfecting" surfaces by coating medical equipment with metals such as copper or silver, or applying liquid compounds that have persistent antimicrobial activity surfaces are additional strategies that require further investigation. Newer "no-touch" (automated) decontamination technologies include aerosol and vaporized hydrogen peroxide, mobile devices that emit continuous ultraviolet (UV-C) light, a pulsed-xenon UV light system, and use of high-intensity narrow-spectrum (405 nm) light. These "no-touch" technologies have been shown to reduce bacterial contamination of surfaces. A micro-condensation hydrogen peroxide system has been associated in multiple studies with reductions in healthcare-associated colonization or infection, while there is more limited evidence of infection reduction by the pulsed-xenon system. A recently completed prospective, randomized controlled trial of continuous UV-C light should help determine the extent to which this technology can reduce healthcare-associated colonization and infections. In conclusion, continued efforts to improve traditional manual disinfection of surfaces are needed. In addition, Environmental Services departments should consider the use of newer disinfectants and no-touch decontamination technologies to improve disinfection of surfaces in healthcare.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Snitkin, E. S., Zelazny, A. M., Thomas, P. J., Stock, F., Program, N. C. S., Henderson, D. K., Palmore, T. N., & Segre, J. A. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3004129 · Cited by 863
Room decontamination with UV radiation
Rutala, W. A., Gergen, M. F., & Weber, D. J. (2010) · Infection Control & Hospital Epidemiology · doi:10.1086/656244 · Cited by 221
Engelbrecht, K., Ambrose, D., Sifuentes, L., Gerba, C., Weart, I., & Koenig, D. (2013) · American Journal of Infection Control · doi:10.1016/j.ajic.2013.01.017 · Cited by 52
Cited by
First hospital outbreak of the globally emerging Candida auris in a European hospital
Schelenz, S., Hagen, F., Rhodes, J. L., Abdolrasouli, A., Chowdhary, A., Hall, A., Ryan, L., Shackleton, J., Trimlett, R., Meis, J. F., et al. (2016) · Antimicrobial Resistance & Infection Control · doi:10.1186/s13756-016-0132-5 · Cited by 768
Multidrug-resistant Candida auris: ‘New kid on the block’ in hospital-associated infections?
Chowdhary, A., Voss, A., & Meis, J. F. (2016) · Journal of Hospital Infection · doi:10.1016/j.jhin.2016.08.004 · Cited by 214
Casini, B., Tuvo, B., Cristina, M. L., Spagnolo, A. M., Totaro, M., Baggiani, A., & Privitera, G. P. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16193572 · Cited by 185
Efficacy of disinfectant-impregnated wipes used for surface disinfection in hospitals: a review
Song, X., Vossebein, L., & Zille, A. (2019) · Antimicrobial Resistance & Infection Control · doi:10.1186/s13756-019-0595-2 · Cited by 132
“In the application of 49 disinfectant in practice, the “ready-to-use” disinfecting wipes (RTUDW) (also reported as pre50 impregnated disinfecting wipes, pre-saturated towelette and pre-wetted disinfecting wipe in some 51 literatures) are increasingly accepted for decontamination of high-touch surfaces because of their…”
D’Accolti, M., Soffritti, I., Mazzacane, S., & Caselli, E. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20071535 · Cited by 82
Saba, C. K. S., Amenyona, J. K., & Kpordze, S. W. (2017) · Antimicrobial Resistance & Infection Control · doi:10.1186/s13756-017-0203-2 · Cited by 60
Metadata
- Authors
- Boyce, J. M.
- Venue
- Antimicrobial Resistance & Infection Control
- Published
- 2016-04-11
- Volume
- 5
- Issue
- 1
- Pages
- 10-10
- ISSN
- 2047-2994 (ISSN-L)
- OpenAlex
- W2328261265
- Cited by
- 442
- References
- 3
- FWCI
- 28.84
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.