High bacterial load of indoor air in hospital wards: the case of University of Gondar teaching hospital, Northwest Ethiopia
Open accessThe DOI matches its Crossref record.
Abstract
BACKGROUND: The air inhaled by people is abundantly populated with microorganisms which also are called bioaerosols. Bioaerosols is a colloidal suspension, formed by liquid droplets and particles of solid matter in the air, whose components contain or have attached to them viruses, fungal spores and conidia, bacterial endospores, plant pollen and fragments of plant tissues. They account for 5-34 % of indoor air pollution. METHODS: A cross-sectional study was conducted to assess the bacteriological concentration and to identify specific species of bacteria in the indoor air of Gondar University teaching hospital. Air samples were taken from 14 randomly selected wards. Bacterial measurements were made by passive air sampling technique i.e., the settle plate method. In each ward five Petri dishes were exposed for 30 and 60 min in the morning and afternoon. Bacteria were collected on nutrient agar and blood agar media. Both quantitative and qualitative analyses were conducted. The quantitative analysis was mainly conducted to determine bacterial load or number of bacteria in the indoor air. Bacterial load was enumerated as colony forming units. Qualitative analysis was conducted to identify specific species of bacteria. For this study we have selected Staphylococcus aureus and Streptococcus which had high public health concern. Mannitol test was used to isolate Staphylococcus aureus, whereas Bacitracin test was conducted to isolate Streptococcus pyogene. RESULT: The result of this study indicated that the highest bacterial load which was 1468 CFU/m(3) has been recorded at 2:00 PM in Ward C at 60 min exposure time and the lowest bacterial concentration (i.e., 480 CFU/m(3)) was recorded at 8:00 AM in physiotherapy ward. Based on the result bacterial concentration of indoor air of Gondar University teaching hospital was found between 480 and 1468 CFU/m(3). The result of one way ANOVA showed that the highest mean bacterial concentration (1271.00 CFU/m(3)) was found in Medical ward and the least (583.25 CFU/m(3)) concentration was found in ward D and the grand total average concentration was 878.43 CFU/m(3). Favorable conditions for growth and multiplication of bacteria like temperature (26.5-29.5 °C), humidity (64.5-85 %), presence of unhygienic attached toilets, poor waste management system and poor ventilation system were observed during the survey. Staphylococcus aureus was identified in 10 wards and Streptococcus pyogenes was isolated in 8 hospital wards. CONCLUSIONS: Compared with different indoor air biological standards, higher concentration of indoor air bacterial load was found in Gondar University teaching hospital. The higher bacterial load may be due to temperature, humidity, presence of unhygienic attached toilets, poor waste management system and poor ventilation system. Therefore, attention must be given to control those environmental factors which favor the growth and multiplication of microbes in indoor environment. In addition, also the ventilation condition, cleanliness of toilets, sweeping methods and waste disposal system of the compound should be improved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bioaerosol assessment of indoor air in hospital wards from a tertiary care hospital
Kotgire, S., Akhtar, R., Damle, A., Siddiqui, S., & Padekar, H. (2020) · Indian Journal of Microbiology Research · doi:10.18231/j.ijmr.2020.007 · Cited by 15
Atalay, Y. A., Mengistie, E., Tolcha, A., Birhan, B., Asmare, G., Gebeyehu, N. A., & Gelaw, K. A. (2023) · Frontiers in Public Health · doi:10.3389/fpubh.2023.1194850 · Cited by 15
Fabiyi, O. C., & Ana, G. R. (2026) · Antimicrobial Resistance & Infection Control · doi:10.1186/s13756-026-01733-8 · Cited by 3
“This study observed a high microbial load above the WHO ≤ 1000 CFU/m 3 guideline for indoor air microbial load [12] [14] and another in Gondar University Teaching Hospital in Northwestern Ethiopia that reported an average of 1468 CFU/m 3 [9].”
Metadata
- Authors
- Gizaw, Z., Gebrehiwot, M., & Yenew, C.
- Venue
- Multidisciplinary Respiratory Medicine
- Publisher
- Mattioli1885
- Published
- 2016-07-05
- Volume
- 11
- Issue
- 1
- Pages
- 24-24
- ISSN
- 1828-695X (ISSN-L)
- 2049-6958
- OpenAlex
- W2385125816
- Cited by
- 73
- References
- 0
- FWCI
- 2.15
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High bacterial load of indoor air in hospital wards: the case of University of Gondar teaching hospital, Northwest Ethiopia. https://app.cochat.ai/papers/10.1186/s40248-016-0061-4
- The paper
- Gizaw, Z., Gebrehiwot, M., & Yenew, C. (2016). High bacterial load of indoor air in hospital wards: the case of University of Gondar teaching hospital, Northwest Ethiopia. Multidisciplinary Respiratory Medicine. https://doi.org/10.1186/s40248-016-0061-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.