CoChat

Indoor air quality, hygiene practices and the antimicrobial resistance profiles of airborne bacteria in selected areas of a tertiary health facility in Ibadan, Nigeria

Open access
Fabiyi, Oluwadamilare Caleb, Ana, Godson Rowland · 2026 · Antimicrobial Resistance & Infection Control

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index; 3 of the 14 sources its claims cite were checked for support.

Abstract

Hospital indoor air is contaminated with multidrug-resistant bacteria, and this contributes to their spread. However, there is limited information linking environmental and atmospheric factors to the levels of these resistant bacteria in indoor hospital air. Hence, this study assessed the levels of multi-drug resistant bacteria in the indoor air of a tertiary hospital and the contributing environmental and atmospheric factors. This cross-sectional study observed hygiene practices, sanitary conditions, occupancy ratio, activity rates, temperature and humidity levels in selected indoor areas of University College Hospital, Ibadan. Airborne bacteria were sampled with their loads via a volumetric sampler, and they were tested for susceptibility against 13 antibiotics via the disk diffusion method. Data was collected twice daily, thrice weekly for two weeks, and analyzed using SPSS version 26. The hygiene practices observed varied across the sampled areas with the office area (10.00 ± 0.00) and psychiatry (9.17 ± 0.41) wards showing best practices, and the laundry area (6.00 ± 0.00) with the worst, sanitary conditions also followed a similar pattern. The study identified 93 bacterial isolates from the MacConkey agar, Staphylococcus aureus (33.3%), Bacillus species (31.18%), Klebsiella pneumoniae (15.05%), Escherichia coli (10.75%), and Coagulase-negative Staphylococcus (9.68%). The mean bacterial load (CFU/m 3 ) varied significantly across sampled areas ( p < 0.01): Laundry (2962.96 ± 547.59) > Children Emergency Ward (2537.03 ± 551.67) > Neurosurgery (2310.19 ± 560.31) > Psychiatry (1828.70 ± 431.93) > Office (421.30 ± 311.09), with the exception of office area, the loads were above the WHO acceptable limit of 1000 CFU/m 3 . Bacterial load correlated negatively with hygiene practices and sanitary conditions, but positively with occupancy ratio, activity levels, humidity and temperature, all p < 0.01. The identified bacteria exhibited a high multidrug resistance, this includes the identification of Methicillin Resistant Staphylococcus aureus and extended spectrum beta lactamases producing Escherichia coli and Klebsiella pneumoniae . Healthcare environments, particularly indoor air remains highly contaminated with multidrug-resistant bacteria, with environmental factors like hygiene, sanitation, occupancy, activity, and atmospheric factors like temperature and humidity contributing to their spread. Therefore, improved environmental practices, routine indoor air surveillance and antimicrobial stewardship is advocated.

Overview

CoChat Summary

## TL;DR

This cross-sectional study in five areas of University College Hospital, Ibadan found that indoor air bacterial loads were highest where hygiene, sanitation, occupancy, activity, temperature, and humidity were less favorable, and most sampled areas exceeded the WHO limit of 1000 CFU/m3. The airborne isolates included common nosocomial pathogens and showed high multidrug resistance, including MRSA and ESBL-producing *E. coli* and *K. pneumoniae*.

## Key findings

  • A total of 93 bacterial isolates were recovered: *Staphylococcus aureus* 33.33% (31), *Bacillus* spp. 31.18% (29), *Klebsiella pneumoniae* 15.05% (14), *Escherichia coli* 10.75% (10), and coagulase-negative staphylococci 9.68% (9).
  • Mean bacterial load differed significantly across areas (F = 47.85, p < 0.01): Laundry 2962.96 ± 547.59 CFU/m3, Children Emergency Ward 2537.03 ± 551.67, Neurosurgery 2310.19 ± 560.31, Psychiatry 1828.70 ± 431.93, and Office 421.30 ± 311.09; all except the office were above the WHO acceptable limit of 1000 CFU/m3.
  • Bacterial load was negatively correlated with sanitary score (r = −0.50, p = 0.01) and hygiene score (r = −0.47, p = 0.01), and positively correlated with occupancy score (r = 0.64, p < 0.01), activity levels (r = 0.61, p < 0.01), temperature (r = 0.56, p < 0.01), and relative humidity (r = 0.72, p < 0.01).
  • Resistance was high: *S. aureus* showed resistance to ampicillin (83.87%), cefoxitin (70.83%), and penicillin (77.42%); *K. pneumoniae* showed 85.71% resistance to clindamycin and *E. coli* 100% resistance to clindamycin; gentamicin remained effective for most isolates, with over 85% susceptibility among gram-positive isolates and 92.86% (*K. pneumoniae*) / 100% (*E. coli*) susceptibility among gram-negatives.

## Methods

  • Design and setting: Descriptive cross-sectional study with field and laboratory components across 5 locations in University College Hospital, Ibadan: Children emergency ward, Neurosurgery, Psychiatry, Laundry, and Office.
  • Data/sample collection: Hygiene practices, sanitary conditions, occupancy ratio, activity level, temperature, and humidity were observed/measured twice daily, thrice weekly for 2 weeks; 60 agar plates were sampled from 15 Feb to 1 Mar 2025 using a single-stage volumetric air sampler.
  • Analysis: Isolates were identified by colony morphology, Gram staining, and biochemical tests, then tested against 13 antibiotics using disk diffusion; data were analyzed in SPSS v26 with mean/SD, Pearson correlation, and ANOVA.

## Limitations

  • The paper states that fungi were not included, and only bacteria were isolated and studied.
  • It states that identification relied on morphological and biochemical methods rather than DNA-based molecular methods.
  • It states that the hospital areas were purposively selected and sampling covered only two weeks, limiting geographic and temporal scope.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1186/s13756-026-01733-8

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Fig. 1 Total Bacterial Load (in CFU/m3) across different locations, periods of the day and week in the health facility
Fig. 1 Total Bacterial Load (in CFU/m3) across different locations, periods of the day and week in the health facilityCC BY-NC-ND · PubMed Central
Fig. 2 Risk matrix of different bacteria species in different hospital areas. LA-Laundry Area, OTCHEW-Children Emergency Ward, NS-Neurosurgery, PS-psychiatry, OF-Office. S. aureus—Staphylococcus aureus, Bacillus spp.—Bacillus species, K. pneumoniae—Klebsiella pneumoniae, E. coli—Escherichia coli, CoNS—Coagulase-negative Staphylococcus
Fig. 2 Risk matrix of different bacteria species in different hospital areas. LA-Laundry Area, OTCHEW-Children Emergency Ward, NS-Neurosurgery, PS-psychiatry, OF-Office. S. aureus—Staphylococcus aureus, Bacillus spp.—Bacillus species, K. pneumoniae—Klebsiella pneumoniae, E. coli—Escherichia coli, CoNS—Coagulase-negative StaphylococcusCC BY-NC-ND · PubMed Central
Fig. 3 Antimicrobial resistance profiles of selected bacteria. S. aureus—Staphylococcus aureus, Bacillus spp.—Bacillus species, K. pneumoniae—Klebsiella pneumoniae, E. coli—Escherichia coli, CoNS—Coagulase-negative Staphylococcus
Fig. 3 Antimicrobial resistance profiles of selected bacteria. S. aureus—Staphylococcus aureus, Bacillus spp.—Bacillus species, K. pneumoniae—Klebsiella pneumoniae, E. coli—Escherichia coli, CoNS—Coagulase-negative StaphylococcusCC BY-NC-ND · PubMed Central

Verification

Claims the paper makes

3 Valid · 0 Not valid · 7 Not checked · 63 Own results and interpretations

43 more claims

Create a free account to see all 73 claims and to verify the 2 references still open.

See all claims — free account
  • It may state two separate claims as one. 18
  • Probably not a substantial claim. 10

Create a free account to see these claims.

Citations

Cites

Show all 26 references

Research works printed but not linked: 4

  1. Agwaranze DI, Ogodo AC, Ezeonu CS, Brow STC, Nwaneri CB, Husie LM. Microbiological assessment of indoor and outdoor air quality in a general hospital in North-East Nigeria. Res J Microbiol. 2020;15:9–14.
  2. CLSI. Performance standards for antimicrobial resistance testing 33rd edition. Clin Lab Stand Inst. 2016;35:16–38.
  3. Heseltine E, Rosen J. WHO guidelines for indoor air quality: Dampness and mould. 2009. World Health Organization. https://www.ncbi.nlm.nih.gov/books/NBK143941/.
  4. Osaro EF, Ufuoma IO, Dorcas AO. Hospital indoor airborne microflora in private and government-owned hospitals in Benin City, Nigeria. World J Med Sci. 2008;3(1):34–8.

Cited by

See all 3

Metadata

Authors
Fabiyi, O. C., & Ana, G. R.
Affiliations
University of Ibadan (NG)
Corresponding author
Fabiyi, Oluwadamilare Caleb
Venue
Antimicrobial Resistance & Infection Control
Published
2026-03-22
Volume
15
Issue
1
ISSN
2047-2994 (ISSN-L)
OpenAlex
W7140037630
Cited by
3
References
25
Citations by year
2026: 3
FWCI
9.50
Type
journal article
Language
en
Open access
Licence
Locations
  • Antimicrobial Resistance and Infection Control (publishedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
  • Health Sciences › Medicine › Infectious Diseases › Infection Control in Healthcare
Keywords
indoor air quality, airborne bacteria, multidrug-resistant bacteria, antimicrobial resistance, sanitary conditions, bacterial load, Staphylococcus aureus, methicillin-resistant Staphylococcus aureus, extended-spectrum beta-lactamase, Klebsiella pneumoniae, Escherichia coli, coagulase-negative staphylococci
MeSH terms
Air Microbiology, Anti-Bacterial Agents, Bacteria, Cross-Sectional Studies, Humans, Hygiene, Microbial Sensitivity Tests, Nigeria, Air Pollution, Indoor, Drug Resistance, Multiple, Bacterial, Tertiary Care Centers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Indoor air quality, hygiene practices and the antimicrobial resistance profiles of airborne bacteria in selected areas of a tertiary health facility in Ibadan, Nigeria. https://app.cochat.ai/papers/10.1186/s13756-026-01733-8
The paper
Fabiyi, O. C., & Ana, G. R. (2026). Indoor air quality, hygiene practices and the antimicrobial resistance profiles of airborne bacteria in selected areas of a tertiary health facility in Ibadan, Nigeria. Antimicrobial Resistance & Infection Control. https://doi.org/10.1186/s13756-026-01733-8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.