Thoracic fluid content: A novel parameter for predicting failed weaning from mechanical ventilation
Open accessAbstract
Abstract Background Weaning of patients from the mechanical ventilation remains one of the critical decisions in intensive care unit. This study aimed to evaluate the accuracy of thoracic fluid content (TFC) as a predictor of weaning outcome. Methods An observational cohort study included 64 critically ill surgical patients who were eligible for extubation. Before initiating the spontaneous breathing trial, the TFC was measured using the electrical cardiometry technology. Patients were followed up after extubation and divided into successful weaning group and failed weaning group. Both groups were compared according to respiratory and cardiovascular parameters. Receiver operating characteristic (ROC) curves were constructed to evaluate the ability of TFC to predict weaning outcome. Results The number of successfully weaned patients was 41/64 (64%). Twenty (31%) patients had impaired cardiac contractility, and of them, 13/20 (64%) patients were successfully extubated. Both groups, successful weaning group and failed weaning group, were comparable in most of baseline characteristics; however, the TFC was significantly higher in the failed weaning group compared to the successful weaning group. The area under the ROC curves (AUCs) showed moderate predictive ability for the TFC in predicting weaning failure (AUC [95% confidence interval] 0.69 [0.57–0.8], cutoff value > 50 kΩ−1), while the predictive ability of TFC was excellent in the subgroup of patients with ejection fraction < 40% (AUC [95% confidence interval 0.93 [0.72–1], cutoff value > 50 kΩ−1). Conclusions Thoracic fluid content showed moderate ability for predicting weaning outcome in surgical critically ill patients. However, in the subgroup of patients with ejection fraction less than 40%, TFC above 50 kΩ−1 has an excellent ability to predict weaning failure.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Thoracic fluid content measured by electrical cardiometry detects pulmonary congestion.
“detecting pulmonary congestion [78]”
From Trends and Challenges in Noninvasive Hemodynamic Monitoring of Neonates Following Cardiac Surgery: A Narrative Review (2025) · cites this paper as [78]
The Methods say TFC was measured by electrical cardiometry, and the Discussion says a high TFC value could be an indirect measure of lung congestion and/or hypervolemia. The claim overstates this qualified interpretation as detection of pulmonary congestion. (LLM, conf=0.84)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 27 · Cited by 36
- Authors
- Fathy, S., Hasanin, A. M., Raafat, M., Mostafa, M. M. A., Fetouh, A. M., Elsayed, M., Badr, E. M., Kamal, H. M., & Fouad, A. Z.
- Affiliations
- Cairo University (EG)
- Corresponding author
- Hasanin, Ahmed M.
- Venue
- Journal of Intensive Care
- Published
- 2020-03-05
- Volume
- 8
- Issue
- 1
- Pages
- 20-20
- ISSN
- 2052-0492 (ISSN-L)
- PMC
- PMC7059362
- OpenAlex
- W3011591963
- Cited by
- 36
- References
- 27
- Citations by year
- 2026: 3 · 2025: 7 · 2024: 13 · 2023: 2 · 2022: 5 · 2021: 4 · 2020: 2
- FWCI
- 1.83
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Journal of Intensive Care (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Greater South Information System
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Health Sciences › Medicine › Epidemiology › Sepsis Diagnosis and Treatment
- Keywords
- thoracic fluid content, weaning from mechanical ventilation, electrical cardiometry, spontaneous breathing trial, cardiac contractility, ejection fraction, critically ill surgical patients, extubation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review