CoChat

Photoacoustic imaging of tumour vascular permeability with indocyanine green in a mouse model

Open access
Okumura, Kenichiro, Yoshida, Kotaro, Yoshioka, Kazuaki, Aki, Sho, Yoneda, Norihide, Inoue, Dai, Kitao, Azusa, Ogi, Takahiro, Kozaka, Kazuto, Minami, Tetsuya, Koda, Wataru, Kobayashi, Satoshi, Takuwa, Yoh, Gabata, Toshifumi · 2018 · European Radiology Experimental
Cited by 35

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

We analysed the haemodynamics of indocyanine green (ICG) in mouse organs and tumours and evaluated responses to anti-angiogenic agents in an allograft tumour mouse model by photoacoustic imaging. Thirty-six male mice (aged 10–14 weeks; body weight 20–25 g) were used. Real-time photoacoustic imaging of organs and tumours after intravenous injection of ICG was conducted in mice until 10 min after ICG injection. ICG distribution in tumour tissues was assessed by immunohistochemical staining and observation of ICG-derived fluorescence. Vascular permeability changes induced by the vascular endothelial growth factor (VEGF)-blocking agent VEGF-trap on tumour photoacoustic signals were studied. The photoacoustic signals in salivary glands and tumours after intravenous injection of iCG (0.604 ± 0.011 and 0.994 ± 0.175 [mean ± standard deviation], respectively) were significantly increased compared with those in the liver, kidney, and great vessel (0.234 ± 0.043, 0.204 ± 0.058 and 0.127 ± 0.040, respectively; p < 0.010). In tumours, the photoacoustic signal increased within 30 s after ICG injection in a dose-dependent manner (r 2 = 0.899) and then decreased gradually. ICG was found to extravasate in tumour tissues. In VEGF-trap-treated mice, the photoacoustic signal in the tumour decreased at the early phase before inhibition of tumour growth was detected (0.297 ± 0.052 vs 1.011 ± 0.170 in the control; p < 0.001). Photoacoustic imaging with ICG administration demonstrated extravasation of ICG in mouse organs and tumours, indicating the potential for early detection of changes in vascular permeability during cancer therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s41747-018-0036-7

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 35

Metadata

Authors
Okumura, K., Yoshida, K., Yoshioka, K., Aki, S., Yoneda, N., Inoue, D., Kitao, A., Ogi, T., Kozaka, K., Minami, T., Koda, W., Kobayashi, S., Takuwa, Y., & Gabata, T.
Venue
European Radiology Experimental
Published
2018-02-27
Volume
2
Issue
1
Pages
5-5
ISSN
2509-9280 (ISSN-L)
OpenAlex
W2797634989
Cited by
35
References
1
FWCI
1.70
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Photoacoustic imaging of tumour vascular permeability with indocyanine green in a mouse model. https://app.cochat.ai/papers/10.1186/s41747-018-0036-7
The paper
Okumura, K., Yoshida, K., Yoshioka, K., Aki, S., Yoneda, N., Inoue, D., Kitao, A., Ogi, T., Kozaka, K., Minami, T., Koda, W., Kobayashi, S., Takuwa, Y., & Gabata, T. (2018). Photoacoustic imaging of tumour vascular permeability with indocyanine green in a mouse model. European Radiology Experimental. https://doi.org/10.1186/s41747-018-0036-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.