CoChat

Robust conductive skin hydrogel e-skin constructed by top–down strategy for motion-monitoring

Open access
Liu, Jiachang, Fan, Xin, Astruc, Didier, Gu, Haibin · 2023 · Collagen and Leather
Cited by 193

The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.

Abstract

The construction of biomass-based conductive hydrogel e-skins with high mechanical properties is the research hotspot and difficulty in the field of biomass materials. Traditional collagen-based conductive hydrogels, constructed by the typical “bottom–up” strategy, normally have the incompatible problem between high mechanical property and high collagen content, and the extraction of collagen is often necessary. To solve these problems, inspired by the high mechanical properties and high collagen content of animal skins, this work proposed a “top–down” construction strategy, in which the extraction of collagen was unnecessary and the skin collagen skeleton (SCS) with the 3D network structure woven by natural collagen fibers in goatskin was preserved and used as the basic framework of hydrogel. Following a four-step route, namely, pretreatment → soaking in AgNPs (silver nanoparticles) solution → soaking in the mixed solution containing HEA (2-hydroxyethyl methacrylate) and AlCl 3 → polymerization, this work successfully achieved the fabrication of a new skin-based conductive hydrogel e-skin with high mechanical properties (tensile strength of 2.97 MPa, toughness of 6.23 MJ·m−3 and breaking elongation of 428%) by using goatskin as raw material. The developed skin hydrogel (called PH@Ag) possessed a unique structure with the collagen fibers encapsulated by PHEA, and exhibited satisfactory adhesion, considerable antibacterial property, cytocompatibility, conductivity (3.06 S·m−1) and sensing sensitivity (the maximum gauge factor of 5.51). The PH@Ag e-skin could serve as strain sensors to accurately monitor and recognize all kinds of human motions such as swallowing, frowning, walking, and so on, and thus is anticipated to have considerable application prospect in many fields including flexible wearable electronic devices, health and motion monitoring. Graphical abstract

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s42825-023-00123-9

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Metadata

Authors
Liu, J., Fan, X., Astruc, D., & Gu, H.
Venue
Collagen and Leather
Published
2023-05-31
Volume
5
Issue
1
ISSN
  • 2097-1419 (ISSN-L)
  • 2731-6998
OpenAlex
W4378906478
Cited by
193
References
37
FWCI
14.16
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.