The DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.
Terahertz spectroscopy in biomedical field: a review on signal-to-noise ratio improvement
Open accessAbstract
With the non-ionizing, non-invasive, high penetration, high resolution and spectral fingerprinting features of terahertz (THz) wave, THz spectroscopy has great potential for the qualitative and quantitative identification of key substances in biomedical field, such as the early diagnosis of cancer, the accurate boundary determination of pathological tissue and non-destructive detection of superficial tissue. However, biological samples usually contain various of substances (such as water, proteins, fat and fiber), resulting in the signal-to-noise ratio (SNR) for the absorption peaks of target substances are very small and then the target substances are hard to be identified. Here, we present recent works for the SNR improvement of THz signal. These works include the usage of attenuated total reflection (ATR) spectroscopy, the fabrication of sample-sensitive metamaterials, the utilization of different agents (including contrast agents, optical clearing agents and aptamers), the application of reconstruction algorithms and the optimization of THz spectroscopy system. These methods have been proven to be effective theoretically, but only few of them have been applied into actual usage. We also analyze the reasons and summarize the advantages and disadvantages of each method. At last, we present the prospective application of THz spectroscopy in biomedical field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ror2 signaling regulates Golgi structure and transport through IFT20 for tumor invasiveness
Nishita, M., Park, S.-Y., Nishio, T., Kamizaki, K., Wang, Z., Tamada, K., Takumi, T., Hashimoto, R., Otani, H., Pazour, G. J., et al. (2017) · Scientific Reports · doi:10.1038/s41598-016-0028-x · Cited by 15,947
Mid-infrared plasmonic biosensing with graphene
Rodrigo, D., Limaj, O., Janner, D., Etezadi, D., García de Abajo, F. J., Pruneri, V., & Altug, H. (2015) · Science · doi:10.1126/science.aab2051 · Cited by 1,462
Non-destructive terahertz imaging of illicit drugs using spectral fingerprints
Kawase, K., Ogawa, Y., Watanabe, Y., & Inoue, H. (2003) · Optics Express · doi:10.1364/oe.11.002549 · Cited by 1,374
Biomedical applications of terahertz technology
Pickwell, E., & Wallace, V. P. (2006) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/39/17/r01 · Cited by 925
Mid-Infrared Plasmonic Biosensing with Graphene
Rodrigo, D., Limaj, O., Janner, D., Etezadi, D., García de Abajo, F. J., Pruneri, V., & Altug, H. (2015) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · Cited by 898
Pulsed terahertz spectroscopy of DNA, bovine serum albumin and collagen between 0.1 and 2.0 THz
Markelz, A. G., Roitberg, A., & Heilweil, E. J. (2000) · Chemical Physics Letters · doi:10.1016/s0009-2614(00)00227-x · Cited by 705
Terahertz pulse imaging in reflection geometry of human skin cancer and skin tissue
Woodward, R. M., Cole, B. E., Wallace, V. P., Pye, R. J., Arnone, D. D., Linfield, E. H., & Pepper, M. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/21/325 · Cited by 702
Far-infrared vibrational modes of DNA components studied by terahertz time-domain spectroscopy
Fischer, B. M., Walther, M., & Jepsen, P. U. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/21/319 · Cited by 588
Terahertz spectroscopy of explosives and drugs
Davies, A. G., Burnett, A. D., Fan, W., Linfield, E. H., & Cunningham, J. E. (2008) · Materials Today · doi:10.1016/s1369-7021(08)70016-6 · Cited by 569
Terahertz pulsed spectroscopy of freshly excised human breast cancer
Ashworth, P. C., Pickwell-MacPherson, E., Provenzano, E., Pinder, S. E., Purushotham, A. D., Pepper, M., & Wallace, V. P. (2009) · Optics Express · doi:10.1364/oe.17.012444 · Cited by 479
Cited by
Jiang, Y., Li, G., Ge, H., Wang, F., Li, L., Chen, X., Lu, M., & Zhang, Y. (2022) · IEEE Access · doi:10.1109/access.2022.3174595 · Cited by 108
Metadata
- Authors
- Peng, Y., Shi, C., Zhu, Y., Gu, M., & Zhuang, S.
- Venue
- PhotoniX
- Published
- 2020-04-13
- Volume
- 1
- Issue
- 1
- ISSN
- 2662-1991 (ISSN-L)
- OpenAlex
- W3029678535
- Cited by
- 300
- References
- 63
- FWCI
- 14.09
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Terahertz spectroscopy in biomedical field: a review on signal-to-noise ratio improvement. https://app.cochat.ai/papers/10.1186/s43074-020-00011-z
- The paper
- Peng, Y., Shi, C., Zhu, Y., Gu, M., & Zhuang, S. (2020). Terahertz spectroscopy in biomedical field: a review on signal-to-noise ratio improvement. PhotoniX. https://doi.org/10.1186/s43074-020-00011-z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.