Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 300

The DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.

Terahertz spectroscopy in biomedical field: a review on signal-to-noise ratio improvement

Open access
Peng, Yan, Shi, Chenjun, Zhu, Yiming, Gu, Min, Zhuang, Songlin·2020·PhotoniX

Abstract

With the non-ionizing, non-invasive, high penetration, high resolution and spectral fingerprinting features of terahertz (THz) wave, THz spectroscopy has great potential for the qualitative and quantitative identification of key substances in biomedical field, such as the early diagnosis of cancer, the accurate boundary determination of pathological tissue and non-destructive detection of superficial tissue. However, biological samples usually contain various of substances (such as water, proteins, fat and fiber), resulting in the signal-to-noise ratio (SNR) for the absorption peaks of target substances are very small and then the target substances are hard to be identified. Here, we present recent works for the SNR improvement of THz signal. These works include the usage of attenuated total reflection (ATR) spectroscopy, the fabrication of sample-sensitive metamaterials, the utilization of different agents (including contrast agents, optical clearing agents and aptamers), the application of reconstruction algorithms and the optimization of THz spectroscopy system. These methods have been proven to be effective theoretically, but only few of them have been applied into actual usage. We also analyze the reasons and summarize the advantages and disadvantages of each method. At last, we present the prospective application of THz spectroscopy in biomedical field.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s43074-020-00011-z

Cites

63 of 63 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 63 references

Cited by

See all 300

Metadata

Authors
Peng, Y., Shi, C., Zhu, Y., Gu, M., & Zhuang, S.
Venue
PhotoniX
Published
2020-04-13
Volume
1
Issue
1
ISSN
2662-1991 (ISSN-L)
OpenAlex
W3029678535
Cited by
300
References
63
FWCI
14.09
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Terahertz spectroscopy in biomedical field: a review on signal-to-noise ratio improvement. https://app.cochat.ai/papers/10.1186/s43074-020-00011-z
The paper
Peng, Y., Shi, C., Zhu, Y., Gu, M., & Zhuang, S. (2020). Terahertz spectroscopy in biomedical field: a review on signal-to-noise ratio improvement. PhotoniX. https://doi.org/10.1186/s43074-020-00011-z

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.