CoChat

The assessment of left ventricular diastolic function: guidance and recommendations from the British Society of Echocardiography

Open access
Robinson, Shaun, Ring, Liam, Oxborough, David, Harkness, Allan, Bennett, Sadie, Rana, Bushra, Sutaria, Nilesh, Lo Giudice, Francesco, Shun-Shin, Matthew, Paton, Maria, Duncan, Rae, Willis, James, Colebourn, Claire, Bassindale, Gemma, Gatenby, Kate, Belham, Mark, Cole, Graham, Augustine, Daniel, Smiseth, Otto A. · 2024 · Echo Research & Practice
Cited by 163

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

Impairment of left ventricular (LV) diastolic function is common amongst those with left heart disease and is associated with significant morbidity. Given that, in simple terms, the ventricle can only eject the volume with which it fills and that approximately one half of hospitalisations for heart failure (HF) are in those with normal/’preserved’ left ventricular ejection fraction (HFpEF) (Bianco et al. in JACC Cardiovasc Imaging. 13:258–271, 2020. 10.1016/j.jcmg.2018.12.035), where abnormalities of ventricular filling are the cause of symptoms, it is clear that the assessment of left ventricular diastolic function (LVDF) is crucial for understanding global cardiac function and for identifying the wider effects of disease processes. Invasive methods of measuring LV relaxation and filling pressures are considered the gold-standard for investigating diastolic function. However, the high temporal resolution of trans-thoracic echocardiography (TTE) with widely validated and reproducible measures available at the patient’s bedside and without the need for invasive procedures involving ionising radiation have established echocardiography as the primary imaging modality. The comprehensive assessment of LVDF is therefore a fundamental element of the standard TTE (Robinson et al. in Echo Res Pract7:G59–G93, 2020. 10.1530/ERP-20-0026). However, the echocardiographic assessment of diastolic function is complex. In the broadest and most basic terms, ventricular diastole comprises an early filling phase when blood is drawn, by suction, into the ventricle as it rapidly recoils and lengthens following the preceding systolic contraction and shortening. This is followed in late diastole by distension of the compliant LV when atrial contraction actively contributes to ventricular filling. When LVDF is normal, ventricular filling is achieved at low pressure both at rest and during exertion. However, this basic description merely summarises the complex physiology that enables the diastolic process and defines it according to the mechanical method by which the ventricles fill, overlooking the myocardial function, properties of chamber compliance and pressure differentials that determine the capacity for LV filling. Unlike ventricular systolic function where single parameters are utilised to define myocardial performance (LV ejection fraction (LVEF) and Global Longitudinal Strain (GLS)), the assessment of diastolic function relies on the interpretation of multiple myocardial and blood-flow velocity parameters, along with left atrial (LA) size and function, in order to diagnose the presence and degree of impairment. The echocardiographic assessment of diastolic function is therefore multifaceted and complex, requiring an algorithmic approach that incorporates parameters of myocardial relaxation/recoil, chamber compliance and function under variable loading conditions and the intra-cavity pressures under which these processes occur. This guideline outlines a structured approach to the assessment of diastolic function and includes recommendations for the assessment of LV relaxation and filling pressures. Non-routine echocardiographic measures are described alongside guidance for application in specific circumstances. Provocative methods for revealing increased filling pressure on exertion are described and novel and emerging modalities considered. For rapid access to the core recommendations of the diastolic guideline, a quick-reference guide (additional file 1) accompanies the main guideline document. This describes in very brief detail the diastolic investigation in each patient group and includes all algorithms and core reference tables.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s44156-024-00051-2

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Metadata

Authors
Robinson, S., Ring, L., Oxborough, D., Harkness, A., Bennett, S., Rana, B., Sutaria, N., Lo Giudice, F., Shun-Shin, M., Paton, M., Duncan, R., Willis, J., Colebourn, C., Bassindale, G., Gatenby, K., Belham, M., Cole, G., Augustine, D., & Smiseth, O. A.
Venue
Echo Research & Practice
Published
2024-06-03
Volume
11
Issue
1
Pages
16-16
ISSN
  • 2055-0456 (ISSN-L)
  • 2055-0464
OpenAlex
W4399296883
Cited by
163
References
12
FWCI
43.78
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The assessment of left ventricular diastolic function: guidance and recommendations from the British Society of Echocardiography. https://app.cochat.ai/papers/10.1186/s44156-024-00051-2
The paper
Robinson, S., Ring, L., Oxborough, D., Harkness, A., Bennett, S., Rana, B., Sutaria, N., Lo Giudice, F., Shun-Shin, M., Paton, M., Duncan, R., Willis, J., Colebourn, C., Bassindale, G., Gatenby, K., Belham, M., Cole, G., Augustine, D., & Smiseth, O. A. (2024). The assessment of left ventricular diastolic function: guidance and recommendations from the British Society of Echocardiography. Echo Research & Practice. https://doi.org/10.1186/s44156-024-00051-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.