Agreement between physiotherapists on quality of movement rated via videotape
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background: Although achieving quality of movement after stroke is an important aim of physiotherapy it is rarely measured objectively or described explicitly. Objective: To test whether physiotherapists agree on a composite measure of quality of movement. Setting: A movement analysis laboratory Subjects: Ten stroke patients and 10 healthy age-matched volunteers. Design: Prospective correlational. Procedure: All subjects were videofilmed performing three trials of six standardized functional tasks. Two videotapes were made, each with a different randomized order of appearance of the trials. Ten senior physiotherapists independently rated the videotapes twice using a 100-mm visual analogue scale. Analysis: Analysis of variance models were fitted to transformed data. Estimates of components of variance were calculated and presented as a percentage of the total variance for differences, within subjects (intra-subject), between raters (inter-rater) and within raters (intra-rater). An acceptable percentage was set at less than 10%. Results: The percentage of intra-subject variance ranged from 1% (pick up box and walking) to 9% (step on block). The percentage of inter-rater variance ranged from 18% (pick up pencil) to 38% (sit to stand). The percentage of intra-rater variance was less than 1% for all tasks. Conclusions: Although physiotherapists disagreed with each other on quality of movement they were more consistent in their own scoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
A comparison of Likert and visual analogue scales for measuring change in function
Guyatt, G. H., Townsend, M., Berman, L. B., & Keller, J. L. (1987) · Journal of Chronic Diseases · doi:10.1016/0021-9681(87)90080-4 · Cited by 456
Cited by
A Novel Approach to Monitor Rehabilitation Outcomes in Stroke Survivors Using Wearable Technology
Patel, S., Hughes, R., Hester, T., Stein, J., Akay, M., Dy, J. G., & Bonato, P. (2010) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2038727 · Cited by 170
Estimating fugl-meyer clinical scores in stroke survivors using wearable sensors
Del Din, S., Patel, S., Cobelli, C., & Bonato, P. (2011) · 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2011.6091444 · Cited by 90
Langhammer, B., & Stanghelle, J. K. (2011) · Physiotherapy Research International · doi:10.1002/pri.474 · Cited by 84
Using Wearable Sensors to Measure Motor Abilities following Stroke
Hester, T., Hughes, R., Sherrill, D. M., Knorr, B., Akay, M., Stein, J., & Bonato, P. (2006) · International Workshop on Wearable and Implantable Body Sensor Networks (BSN'06) · doi:10.1109/bsn.2006.57 · Cited by 82
“Keywords: Wearable Sensors, Stroke, Clinical Assessment”
Towards an IoT-based upper limb rehabilitation assessment system
Jiang, Y., Qin, Y., Kim, I., & Wang, Y. (2017) · 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8037343 · Cited by 26
“Thus the accuracy may decline and the result may vary across different physicians [6].”
Background
Metadata
- Authors
- Pomeroy, V. M., Pramanik, A., Sykes, L., Richards, J., & Hill, E.
- Venue
- Clinical Rehabilitation
- Publisher
- SAGE Publications
- Published
- 2003-05
- Volume
- 17
- Issue
- 3
- Pages
- 264-272
- ISSN
- 0269-2155 (ISSN-L)
- 1477-0873
- OpenAlex
- W2145774222
- Cited by
- 44
- References
- 2
- FWCI
- 1.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Agreement between physiotherapists on quality of movement rated via videotape. https://app.cochat.ai/papers/10.1191/0269215503cr607oa
- The paper
- Pomeroy, V. M., Pramanik, A., Sykes, L., Richards, J., & Hill, E. (2003). Agreement between physiotherapists on quality of movement rated via videotape. Clinical Rehabilitation. https://doi.org/10.1191/0269215503cr607oa
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.