Long-term mobility monitoring of older adults using accelerometers in a clinical environment
The DOI matches its Crossref record.
Abstract
Objective: To assess the accuracy of accelerometer-based mobility monitoring during extended measurements on older adults in a clinical setting and to evaluate two different approaches to thresholding. Design: The monitoring device consisted of two Analog Devices ADXL202 accelerometers, an ambulatory data-logger and associated cabling. The monitoring system used custom-designed analysis software to detect activities of daily living, namely duration of sitting, standing, lying and moving during the period monitored. An investigator shadowed the subjects throughout the recording period. Subjects and setting: This study monitored five older adults, with varying degrees of mobility, resident in a rehabilitation clinic, over four days. Interventions: The accelerometer data were analysed using a MATLABÒ program that allowed trunk and thigh threshold angles to be set to distinguish between sitting, standing, lying and moving. Two different approaches to setting these thresholds were investigated: (1) using a midpoint tolerance value of 458 and (2) using a `best estimate' tolerance value. The analysis program generates a summary of activities, which is then compared line-by-line with the manual summary created by the observer. The result was a hit/miss ratio representative of the system's accuracy. Results: The detection accuracies for sitting and lying using a mid-point tolerance value were poor, with an average detection accuracy of 75% obtained. The `best estimate' approach improved the detection accuracies for sitting and lying by approximately 18% to an average value of 93%. Conclusion: In a population of older adults, the static activities of sitting, standing and lying and dynamic activities can be distinguished using the technique and threshold values outlined here to a degree of accuracy of 92% and higher.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Evaluation of a threshold-based tri-axial accelerometer fall detection algorithm
Bourke, A. K., O’Brien, J. V., & Lyons, G. M. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2006.09.012 · Cited by 821
Self-citationPhysical Human Activity Recognition Using Wearable Sensors
Attal, F., Mohammed, S., Dedabrishvili, M., Chamroukhi, F., Oukhellou, L., & Amirat, Y. (2015) · Sensors · doi:10.3390/s151229858 · Cited by 796
Activity identification using body-mounted sensors—a review of classification techniques
Preece, S. J., Goulermas, J. Y., Kenney, L. P. J., Howard, D., Meijer, K., & Crompton, R. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/4/r01 · Cited by 600
Direct measurement of human movement by accelerometry
Godfrey, A., Conway, R., Meagher, D., & ÓLaighin, G. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.09.005 · Cited by 591
Methods of Measurement in epidemiology: Sedentary Behaviour
Atkin, A. J., Gorely, T., Clemes, S. A., Yates, T., Edwardson, C., Brage, S., Salmon, J., Marshall, S. J., & Biddle, S. J. (2012) · International Journal of Epidemiology · doi:10.1093/ije/dys118 · Cited by 518
Metadata
- Authors
- Culhane, K. M., Lyons, G. M., Hilton, D., Grace, P. A., & Lyons, D.
- Venue
- Clinical Rehabilitation
- Publisher
- SAGE Publications
- Published
- 2004-05
- Volume
- 18
- Issue
- 3
- Pages
- 335-343
- ISSN
- 0269-2155 (ISSN-L)
- 1477-0873
- OpenAlex
- W2151385582
- Cited by
- 94
- References
- 0
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Long-term mobility monitoring of older adults using accelerometers in a clinical environment. https://app.cochat.ai/papers/10.1191/0269215504cr734oa
- The paper
- Culhane, K. M., Lyons, G. M., Hilton, D., Grace, P. A., & Lyons, D. (2004). Long-term mobility monitoring of older adults using accelerometers in a clinical environment. Clinical Rehabilitation. https://doi.org/10.1191/0269215504cr734oa
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.