Reliability of simple portable tests of physical performance in older people after hip fracture
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Objective: To investigate the test–retest reliability of measures of strength, balance, gait and functional performance when used with older people following hip fracture. Subjects: Thirty people (16 hospital inpatients and 14 community dwellers). Design: Subjects underwent two assessments: one day apart for the hospital inpatients and one week apart for the community dwellers. Measurement: Strength (dynamometer, sphygmomanometer, spring balance, lateral step-up ability), balance (sway-meter, Functional Reach Test, single leg stance time, Step Test), gait (timed 6-m walk with steps taken, base of support and step length), and functional performance (PPME total score and timed supine-to-sit and sit-to-stand) were measured. Results: Eleven of the 14 continuously scaled measurement tools achieved excellent reliability (intraclass correlation coefficient (ICC)>0.75) for one or more tests. A hand-held dynamometer was found to be the tool with the highest test–retest reliability for measuring hip muscle strength (ICC (3,1) 0.86 for affected hip abduction). For measurement of knee extension strength, a spring balance (ICC (3,1) 0.94 affected leg) was the most reliable. For testing balance, the Step Test (ICC (3,1) 0.94 for stepping with affected leg) and Functional Reach Test (ICC (3,1) 0.89) had the highest test–retest reliability. The ICC (3,1) values were 0.97 for walking velocity (comfortable pace) and 0.96 for the total score of the Physical Performance and Mobility Examination. Conclusion: The test–retest reliability of a number of simple measures of physical performance is excellent when used with this population.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Steffen, T. M., Hacker, T. A., & Mollinger, L. (2002) · Physical Therapy · doi:10.1093/ptj/82.2.128 · Cited by 2,070
Cited by
Steffen, T., & Seney, M. (2008) · Physical Therapy · doi:10.2522/ptj.20070214 · Cited by 860
Assessing walking speed in clinical research: a systematic review
Graham, J. E., Ostir, G. V., Fisher, S. R., & Ottenbacher, K. J. (2008) · Journal of Evaluation in Clinical Practice · doi:10.1111/j.1365-2753.2007.00917.x · Cited by 428
Myostatin antibody (LY2495655) in older weak fallers: a proof-of-concept, randomised, phase 2 trial
Becker, C., Lord, S. R., Studenski, S. A., Warden, S. J., Fielding, R. A., Recknor, C. P., Hochberg, M. C., Ferrari, S. L., Blain, H., Binder, E. F., et al. (2015) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(15)00298-3 · Cited by 381
Self-citationCore outcomes for adult burn survivors: A clinical overview
Falder, S., Browne, A., Edgar, D., Staples, E., Fong, J., Rea, S., & Wood, F. (2009) · Burns · doi:10.1016/j.burns.2008.09.002 · Cited by 222
“[113] Sherrington C, Stephen R.”
BackgroundMcDonough, C. M., Harris-Hayes, M., Kristensen, M. T., Overgaard, J. A., Herring, T. B., Kenny, A. M., & Mangione, K. K. (2021) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2021.0301 · Cited by 211
Metadata
- Authors
- Sherrington, C., & Lord, S. R.
- Venue
- Clinical Rehabilitation
- Publisher
- SAGE Publications
- Published
- 2005-08
- Volume
- 19
- Issue
- 5
- Pages
- 496-504
- ISSN
- 0269-2155 (ISSN-L)
- 1477-0873
- OpenAlex
- W2130794596
- Cited by
- 103
- References
- 2
- FWCI
- 6.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.