Introduction to Bayesian methods III: use and interpretation of Bayesian tools in design and analysis
The DOI matches its Crossref record.
Abstract
The Bayesian approach and several of its advantages in drug and medical device development are described. One advantage from the perspective of analysis is that it provides a methodology for synthesizing information. However, taking a Bayesian approach to designing clinical trials is potentially more valuable than using this approach in analyzing trial results. Bayesian methodology provides a mechanism for updating what is known as results accumulate during a trial. Such updating can be incorporated completely explicitly and prospectively. An important way in which the Bayesian approach can be used is in calculating the predictive probability distribution of future results on the basis of current results. I show how to exploit predictive distributions in adapting to results that accumulate during the course of a trial. Possible adaptations including decreasing or increasing sample size, dropping treatment arms, and modifying the randomization proportions to the various arms depending on the interim results. Consequences of taking a Bayesian approach to clinical trial design are efficiency, better treatment of patients in the trial, and greater precision regarding the primary endpoints. An example of the last of these is Bayesian modeling of the relationship between early and longer term endpoints. Such modeling also enables earlier decision making. Case studies 2 and 3 deal with trials that were shorter and smaller, respectively, because of such modeling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wilber, D. J., Pappone, C., Neuzil, P., De Paola, A., Marchlinski, F., Natale, A., Macle, L., Daoud, E. G., Calkins, H., Hall, B., et al. (2010) · JAMA · doi:10.1001/jama.2009.2029 · Cited by 1,170
“The protocol-defined primary statistical analysis of the primary end points was Bayesian.(19-21) Study success required a probability of superiority of catheter ablation over ADT in the primary end point at the final analysis of at least 98% to control the type I error rate at no more than 2.”
MethodInfluentialSelf-citationDe testimonio: on the evidence for decisions about the use of therapeutic interventions
Rawlins, M. (2008) · The Lancet · doi:10.1016/s0140-6736(08)61930-3 · Cited by 362
REVIEW OF TREATMENT TRIALS IN HUMANSPINAL CORD INJURY: ISSUES, DIFFICULTIES, AND RECOMMENDATIONS
Tator, C. H. (2006) · Neurosurgery · doi:10.1227/01.neu.0000245591.16087.89 · Cited by 303
Adaptive clinical trials in oncology
Berry, D. A. (2012) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2011.165 · Cited by 267
Self-citationDe Testimonio: on the evidence for decisions about the use of therapeutic interventions
Rawlins, M. (2008) · Clinical Medicine · doi:10.7861/clinmedicine.8-6-579 · Cited by 220
Metadata
- Authors
- Berry, D. A.
- Venue
- Clinical Trials
- Publisher
- SAGE Publications
- Published
- 2005-08
- Volume
- 2
- Issue
- 4
- Pages
- 295-300
- ISSN
- 1740-7745 (ISSN-L)
- 1740-7753
- OpenAlex
- W2007702124
- Cited by
- 99
- References
- 0
- FWCI
- 4.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Introduction to Bayesian methods III: use and interpretation of Bayesian tools in design and analysis. https://app.cochat.ai/papers/10.1191/1740774505cn100oa
- The paper
- Berry, D. A. (2005). Introduction to Bayesian methods III: use and interpretation of Bayesian tools in design and analysis. Clinical Trials. https://doi.org/10.1191/1740774505cn100oa
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.