The DOI matches its Crossref record.
A specific, accurate, and sensitive measure of total plasma malondialdehyde by HPLC
Open accessAbstract
Malondialdehyde (MDA) is one of the most commonly reported biomarkers of lipid peroxidation in clinical studies. The reaction of thiobarbituric acid (TBA) with MDA to yield a pink chromogen attributable to an MDA-TBA₂ adduct is a common assay approach with products being quantified by ultraviolet-Vis assay as nonspecific TBA-reactive substances (TBARS) or chromatographically as MDA. The specificity of the TBARS assay was compared with both chromatographic assays for total plasma MDA. The levels of total plasma MDA were significantly lower than the plasma TBARS in each of the samples examined, and interestingly, the interindividual variation apparent in the level of plasma MDA was not evident in the plasma TBARS assay. Each of the four online chromatographic detectors yielded a precise, sensitive, and accurate determination of total plasma MDA, and selected-ion monitoring was the most-accurate assay (101.3%, n = 4). The online diode array detectors provided good assay specificity (peak purity index of 999), sensitivity, precision, and accuracy. This research demonstrates the inaccuracy that is inherent in plasma TBARS assays, which claim to quantify MDA, and it is proposed that the TBARS approach may limit the likelihood of detecting true differences in the level of lipid peroxidation in clinical studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ito, F., Sono, Y., & Ito, T. (2019) · Antioxidants · doi:10.3390/antiox8030072 · Cited by 535
Aleksandrova, K., Koelman, L., & Rodrigues, C. E. (2021) · Redox Biology · doi:10.1016/j.redox.2021.101869 · Cited by 505
Noctor, G., Mhamdi, A., & Foyer, C. H. (2016) · Plant, Cell & Environment · doi:10.1111/pce.12726 · Cited by 406
Mas-Bargues, C., Escrivá, C., Dromant, M., Borrás, C., & Viña, J. (2021) · Archives of Biochemistry and Biophysics · doi:10.1016/j.abb.2021.108941 · Cited by 344
Chemistry and analysis of HNE and other prominent carbonyl-containing lipid oxidation compounds
Sousa, B. C., Pitt, A. R., & Spickett, C. M. (2017) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2017.02.003 · Cited by 172
Metadata
- Authors
- Moselhy, H. F., Reid, R. G., Yousef, S., & Boyle, S. P.
- Venue
- Journal of Lipid Research
- Publisher
- Elsevier BV
- Published
- 2013-03
- Volume
- 54
- Issue
- 3
- Pages
- 852-858
- ISSN
- 0022-2275 (ISSN-L)
- OpenAlex
- W2117737656
- Cited by
- 188
- References
- 0
- FWCI
- 3.37
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A specific, accurate, and sensitive measure of total plasma malondialdehyde by HPLC. https://app.cochat.ai/papers/10.1194/jlr.d032698
- The paper
- Moselhy, H. F., Reid, R. G., Yousef, S., & Boyle, S. P. (2013). A specific, accurate, and sensitive measure of total plasma malondialdehyde by HPLC. Journal of Lipid Research. https://doi.org/10.1194/jlr.d032698
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.