Emergency Nurses' Utilization of Ultrasound Guidance for Placement of Peripheral Intravenous Lines in Difficult‐access Patients

Open access
Brannam, Larry, Blaivas, Michael, Lyon, Matthew, Flake, Michael · 2004 · Academic Emergency Medicine

Abstract

Objectives: Emergency nurses (ENs) typically place peripheral intravenous (IV) lines, but if repeated attempts fail, emergency physicians have to obtain peripheral or central access. The authors describe the patient population for which ultrasound (US)‐guided peripheral IVs are used and evaluate the success rates for such lines by ENs. Methods: This was a prospective observational study of ENs in a Level I trauma center with a census of 75,000, performing US‐guided IV line placement on difficult‐to‐stick patients (repeated blind IV placement failure or established history). ENs were trained on an inanimate model after a 45‐minute lecture. Surveys were filled out after each US‐guided IV attempt on a patient. ENs could decline to fill out surveys, which recorded the reason for use of US, type of patient, and success. Successful cannulation was confirmed by drawing blood and flushing fluids. Descriptive statistics were used to evaluated data. Results: A total of 321 surveys were collected in a five‐month period no ENs declined to participate. There were 280 (87%) successful attempts. Twelve (29%) of the 41 failure patients required central lines, 9 (22%) received external jugular IVs, and 20 (49%) had peripheral IV access placed under US guidance by another nurse or physician. Twenty‐eight percent (90) of all patients were obese, 18% (57) had sickle cell anemia, 10% (31) were renal dialysis patients, 12% (40) were IV drug abusers, and 19% (61) had unspecified chronic illness. The remainder had no reason for difficult access given. There were four arterial punctures. Conclusions: ENs had a high success rate and few complications with use of US guidance for vascular access in a variety of difficult‐access patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1197/j.aem.2004.08.027

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 179

Metadata

Authors
Brannam, L., Blaivas, M., Lyon, M., & Flake, M.
Venue
Academic Emergency Medicine
Publisher
Wiley
Published
2004-12
Volume
11
Issue
12
Pages
1361-1363
ISSN
  • 1069-6563 (ISSN-L)
  • 1553-2712
OpenAlex
W2167351210
Cited by
179
References
0
FWCI
5.77
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Emergency Nurses' Utilization of Ultrasound Guidance for Placement of Peripheral Intravenous Lines in Difficult‐access Patients. https://app.cochat.ai/papers/10.1197/j.aem.2004.08.027
The paper
Brannam, L., Blaivas, M., Lyon, M., & Flake, M. (2004). Emergency Nurses' Utilization of Ultrasound Guidance for Placement of Peripheral Intravenous Lines in Difficult‐access Patients. Academic Emergency Medicine. https://doi.org/10.1197/j.aem.2004.08.027

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.