Evaluation of a Physician Informatics Tool to Improve Patient Handoffs
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
OBJECTIVE To facilitate patient handoffs between physicians, the computerized patient handoff tool (PHT) extracts information from the electronic health record to populate a form that is printed and given to the cross-cover physician. OBJECTIVES were to: (1) evaluate the rate at which data elements of interest were extracted from the electronic health record into the PHT, (2) assess the frequency for needing information beyond that contained in the PHT and where obtained, (3) assess physician's perceptions of the PHT, (4) identify opportunities for improvement. DESIGN Observational study. MEASUREMENTS This multi-method study included content coding of PHT forms, end of shift surveys of cross-cover resident physicians, and semi-structured interviews to identify opportunities for improvement. Thirty-five of 42 internal medicine resident physicians participated. Measures included: 1264 PHT forms coded for type of information, 63 end-of-shift surveys of cross-cover residents (residents could participate 2 times), and 18 semi-structured interviews. RESULTS For objective 1, patient identifiers and medications were reliably extracted (>98%). Other types of information-allergies and code status-were more variable (<50%). For objective 2, nearly a quarter of respondents required information from physician notes not available in the PHT. For objective 3, respondents found that the PHT supported handoffs but indicated that it often excluded the assessment and plan. For objective 4, residents suggested including treatment plans. CONCLUSIONS The PHT reliably extracts information from the electronic health record. Respondents found the PHT to be suitable, although opportunities for improvement were identified.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistical Analysis of Correlated Data Using Generalized Estimating Equations: An Orientation
Hanley, J. A. (2003) · American Journal of Epidemiology · doi:10.1093/aje/kwf215 · Cited by 2,185
Does Housestaff Discontinuity of Care Increase the Risk for Preventable Adverse Events?
Petersen, L. A., Brennan, T. A., O'Neil, A. C., Cook, E. F., & Lee, T. H. (1994) · Annals of Internal Medicine · doi:10.7326/0003-4819-121-11-199412010-00008 · Cited by 665
Solet, D. J., Norvell, J. M., Rutan, G. H., & Frankel, R. M. (2005) · Academic Medicine · doi:10.1097/00001888-200512000-00005 · Cited by 531 · cited 1×
“Clinicians at the Indianapolis Veterans Affairs (VA) Medical Center use a computerized patient handoff tool (PHT).”
Self-citation
Cited by
Patient Handoffs: Standardized and Reliable Measurement Tools Remain Elusive
Patterson, E. S., & Wears, R. L. (2010) · The Joint Commission Journal on Quality and Patient Safety · doi:10.1016/s1553-7250(10)36011-9 · Cited by 265
Self-citationHARVEST, a longitudinal patient record summarizer
Hirsch, J. S., Tanenbaum, J. S., Lipsky Gorman, S., Liu, C., Schmitz, E., Hashorva, D., Ervits, A., Vawdrey, D., Sturm, M., & Elhadad, N. (2015) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2014-002945 · Cited by 135
Flemming, D., & Hübner, U. (2013) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2013.03.004 · Cited by 102
Staggers, N., Clark, L., Blaz, J. W., & Kapsandoy, S. (2011) · Health Informatics Journal · doi:10.1177/1460458211405809 · Cited by 76
(2011) · Europe PMC (PubMed Central) · Cited by 46
Metadata
- Authors
- Flanagan, M. E., Patterson, E. S., Frankel, R. M., & Doebbeling, B. N.
- Venue
- Journal of the American Medical Informatics Association
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-07-01
- Volume
- 16
- Issue
- 4
- Pages
- 509-515
- ISSN
- 1067-5027 (ISSN-L)
- 1527-974X
- OpenAlex
- W175492607
- Cited by
- 79
- References
- 3
- FWCI
- 9.27
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.