The DOI matches its Crossref record.
Complications of indwelling venous access devices in cancer patients.
Abstract
PURPOSE: We undertook this study to review our experience with indwelling vascular access devices in cancer patients to identify factors associated with complications. PATIENTS AND METHODS: A total of 322 indwelling devices were placed in 274 cancer patients by a single surgeon. Devices were placed via percutaneous insertion in 72% (231 of 322) and via venous cutdown in 28% (91 of 322). We placed external catheters in 209 of 322 patients (65%) and subcutaneous infusion ports in 113 of 322 (35%). RESULTS: Pneumothorax occurred in four of 231 (1.7%) of the percutaneously placed devices. Postoperative complications included sepsis and thrombosis, which necessitated premature removal of the devices. Device related sepsis occurred in 28 of 209 patients (13%) with catheters and six of 113 patients (5%) with subcutaneous ports. Thrombosis occurred in 21 of 209 patients (10%) with catheters and seven of 113 (6%) with subcutaneous ports. In 15 of 19 devices removed for thrombosis, the tip was above the T3 level. Seventeen devices were placed in the saphenous vein, with a complication rate similar to that observed in upper-body devices. CONCLUSION: We found a significantly (P < .05, chi 2 analysis) increased incidence of thrombotic complications in patients with triple-lumen catheters (10 of 48) compared with double-lumen catheters (11 of 160), as well as a significantly (P < .05) decreased mean time until catheter failure (40 v 146 days). We also observed a significant increase in the rate of thrombosis in patients with a catheter tip above the T3 level. We therefore recommend the use of fluoroscopy at the time of placement to assure adequate catheter length and tip position and the use of triple-lumen catheters only when necessary for concurrent drug administration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Venous Thromboembolism Associated With Long-Term Use of Central Venous Catheters in Cancer Patients
Verso, M., & Agnelli, G. (2003) · Journal of Clinical Oncology · doi:10.1200/jco.2003.08.008 · Cited by 605
Deep-Vein Thrombosis of the Upper Extremities
Kucher, N. (2011) · New England Journal of Medicine · doi:10.1056/nejmcp1008740 · Cited by 373
DEBOURDEAU, P., FARGE, D., BECKERS, M., BAGLIN, C., BAUERSACHS, R. M., BRENNER, B., BRILHANTE, D., FALANGA, A., GEROTZAFIAS, G. T., HAIM, N., et al. (2013) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.12071 · Cited by 316
Catheter-Associated Thrombosis in Patients With Malignancy
Shivakumar, S. P., Anderson, D. R., & Couban, S. (2009) · Journal of Clinical Oncology · doi:10.1200/jco.2009.22.6126 · Cited by 77
Metadata
- Authors
- Eastridge, B. J., & Lefor, A. T.
- Venue
- Journal of Clinical Oncology
- Published
- 1995-01
- Volume
- 13
- Issue
- 1
- Pages
- 233-238
- ISSN
- 0732-183X (ISSN-L)
- 1527-7755
- OpenAlex
- W2127250545
- Cited by
- 217
- References
- 0
- FWCI
- 22.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Complications of indwelling venous access devices in cancer patients. https://app.cochat.ai/papers/10.1200/jco.1995.13.1.233
- The paper
- Eastridge, B. J., & Lefor, A. T. (1995). Complications of indwelling venous access devices in cancer patients. Journal of Clinical Oncology. https://doi.org/10.1200/jco.1995.13.1.233
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.